Schneider A9K02325 Acti9 K60N MCB 3P 25 A C Curve 6kA DIN Rail

Free Shipping

Get free shipping on orders exceeding €300!

Original price $12.09 - Original price $12.09
Original price
$12.09
$12.09 - $12.09
Current price $12.09

The Schneider Electric A9K02325 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 K60N range, rated at 25 A with a C tripping curve and 6 kA breaking capacity at 400 V AC. It uses thermomagnetic protection technology to guard three-phase AC circuits against overload and short-circuit faults, and is approved for use as an isolating device per EN/IEC 60898-1.

Technical specifications:

  • Commercial reference: A9K02325
  • Manufacturer: Schneider Electric
  • EAN:
  • Series / range: Acti 9 K60
  • Number of poles: 3P
  • Number of protected poles: 3
  • Rated current (In): 25 A
  • Network type: AC, 50/60 Hz
  • Protection technology: Thermomagnetic
  • Tripping curve: C
  • Breaking capacity (Icn): 6000 A at 400 V AC 50/60 Hz
  • Service breaking capacity (Ics): 6000 A (100%) at 400 V AC 50/60 Hz
  • Rated isolation voltage (Ui): 440 V AC 50/60 Hz
  • Rated impulse withstand voltage (Uimp): 4 kV
  • Overcurrent protection range: 5...10 x In
  • Limitation class: 3
  • Mounting: DIN rail, fixed
  • Dimensions (W x H x D): 54 x 81 x 70 mm
  • Weight: 0.36 kg
  • IP rating: IP20
  • Operating temperature: -25...70°C
  • Storage temperature: -40...70°C
  • Connection terminals: Tunnel type, 0.5...35 mm² rigid / 0.5...25 mm² flexible (upper and lower)
  • Tightening torque: 3.5 N.m
  • Mechanical durability: 20,000 cycles
  • Electrical durability: 10,000 cycles
  • Certifications: OVE, VDE
  • Standard: EN/IEC 60898-1

Features and benefits:

  • Thermomagnetic trip unit provides both thermal overload and instantaneous magnetic short-circuit protection in a single device
  • Ics equals 100% of Icn, delivering full-rated service breaking capacity without derating
  • Approved for isolation duty per EN/IEC 60898-1, removing the need for a separate disconnector
  • Compatible with comb busbars via double-connection lower terminals, simplifying three-phase distribution wiring
  • Limitation class 3 minimises let-through energy, reducing thermal and mechanical stress on downstream equipment
  • Wide operating range from -25 to 70°C suits both indoor distribution boards and more demanding industrial enclosures

Applications:

  • Final distribution boards in commercial and industrial buildings
  • Three-phase branch circuit protection in residential and tertiary electrical installations
  • Industrial control panels and machine switchboards requiring thermomagnetic MCB protection
  • Sub-distribution switchboards where isolation capability is required at the breaker

Compliant with EN/IEC 60898-1. Part of the Schneider Electric Acti 9 range.

Also known as: Schneider A9K02325, Schneider Electric A9K02325, Acti 9 K60N 3P 25A C curve MCB, Schneider 3-pole miniature circuit breaker 25A.