Schneider A9F83116 Miniature Circuit Breaker (MCB), Acti9 iC60H, 1P, 16A, B curv
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric A9F83116 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60H range, rated at 16A with a B tripping curve. It provides thermomagnetic overcurrent protection for AC and DC networks, with a breaking capacity of 10,000A at 230V AC per IEC/EN 60898-1 and up to 15kA at 220-240V AC per IEC/EN 60947-2.
Technical specifications:
- Commercial reference: A9F83116
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 iC60
- Product type: Miniature Circuit Breaker (MCB)
- Short designation: iC60H
- Number of poles: 1P
- Number of protected poles: 1
- Rated current: 16A
- Tripping curve: B
- Network type: AC / DC
- Trip unit technology: Thermomagnetic
- Breaking capacity: 10,000A Icn at 230V AC per EN/IEC 60898-1; 15kA Icu at 220-240V AC per EN/IEC 60947-2; 42kA Icu at 12-60V AC per EN/IEC 60947-2; 15kA Icu at 72V DC per EN/IEC 60947-2
- Limitation class: 3 per EN/IEC 60898-1
- Rated insulation voltage: 500V AC at 50/60 Hz
- Rated impulse withstand voltage: 6kV
- Overcurrent limit: 4 x In +/- 20%
- Network frequency: 50/60 Hz
- Mounting: DIN rail
- Width: 18mm (2 x 9mm rows)
- Height: 85mm
- Depth: 78.5mm
- Weight: 0.215kg
- IP rating: IP20 per IEC/EN 60529
- Operating temperature: -35 to 70°C
- Storage temperature: -40 to 85°C
- Relative humidity: 95% at 55°C
- Connection: Single terminal block 1-25mm² rigid / 1-16mm² flexible; strip length 14mm; tightening torque 2 N.m
- Mechanical durability: 20,000 cycles
- Electrical durability: 10,000 cycles
- Standards: IEC 60898-1, EN 60898-1, IEC 60947-2, EN 60947-2
- Warranty: 18 months
Features and benefits:
- High breaking capacity of 10kA at 230V AC (IEC/EN 60898-1) and 15kA at 220-240V AC (IEC/EN 60947-2) for robust protection in demanding installations
- Suitable for both AC and DC networks, providing flexibility across different electrical systems
- B tripping curve for protection of sensitive circuits and loads with low inrush currents
- Compact 18mm width with comb busbar compatibility (upper or lower) for space-efficient panel design
- Trip indication and contact position indicator for quick status identification without opening the panel
- Limitation class 3 for reduced let-through energy, minimising thermal and mechanical stress on downstream equipment
Applications:
- Final distribution boards in residential and light commercial buildings
- Protection of lighting circuits and sensitive electronic equipment requiring B-curve characteristics
- Low-voltage electrical panels in industrial and commercial installations
- DC circuit protection in photovoltaic and battery systems (up to 72V DC)
- Electrical energy distribution systems requiring IEC/EN 60947-2 compliance
Compliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.
Also known as: Schneider A9F83116, Schneider Electric A9F83116, Acti9 iC60H 1P 16A B-curve MCB, Schneider 16A miniature circuit breaker.