Eaton 286601 PL6-C16/3 MCB 3P 16 A C Curve 6kA DIN Rail
Free Shipping
Get free shipping on orders exceeding €300!
The Eaton PL6-C16/3 (catalog number 286601) is a 3-pole miniature circuit breaker from the Eaton Moeller series xPole range, providing overcurrent and short-circuit protection in residential and commercial switchgear. Rated at 16 A with tripping characteristic C, it delivers a rated short-circuit breaking capacity of 6 kA at both 230 V and 400 V in compliance with IEC/EN 60898-1.
Technical specifications:
- Model code: PL6-C16/3
- Catalog number: 286601
- Manufacturer: Eaton
- EAN: 4015082866013
- Type: Miniature circuit breaker
- Number of poles: 3
- Tripping characteristic: C
- Rated current (In): 16 A
- Rated switching capacity (IEC/EN 60898-1): 6 kA
- Rated short-circuit breaking capacity (ICN at 230 V): 6 kA
- Rated short-circuit breaking capacity (ICN at 400 V): 6 kA
- Rated operational voltage (UE) max: 400 V
- Rated insulation voltage (Ui): 440 V
- Rated impulse withstand voltage (Uimp): 4 kV
- Overvoltage category: III
- Degree of protection: IP20
- Pollution degree: 2
- Current limiting class: 3
- Voltage type: AC
- Frequency rating: 50-60 Hz
- Ambient operating temperature: -25 °C to 75 °C
- Width: 3 modular spacings
- Dimensions (W x H x D): 53.1 x 73 x 85 mm
- Built-in depth: 70.5 mm
- Weight: 0.36 kg
- Connectable conductor cross section (solid-core): 1-25 mm²
- Connectable conductor cross section (multi-wired): 1-25 mm²
- Power loss: 7.2 W
- Equipment heat dissipation (current-dependent): 6.9 W
- Compliances: RoHS conform
Features and benefits:
- 3-pole design simultaneously disconnects all live conductors, suited to three-phase circuit protection
- Characteristic C handles moderate inrush currents from inductive loads such as motors and HVAC equipment
- Current limiting class 3 minimises let-through energy during short-circuit events, protecting downstream equipment
- Wide conductor compatibility of 1-25 mm² (solid-core and multi-wired) simplifies installation across cable sizes
- Supports additional accessories, allowing the breaker to be extended with auxiliary contacts or shunt trips
- Each 1 °C rise in ambient temperature reduces current carrying capacity by 0.5%, allowing precise thermal derating
Applications:
- Three-phase circuit protection in residential distribution boards
- Feeder and sub-circuit protection in commercial switchgear panels
- Protection of inductive loads including pumps, motors, and HVAC units
- DIN rail installations in metering cabinets and consumer units
- Industrial panel builds requiring IEC/EN 60898-1 compliant overcurrent protection
Compliant with IEC/EN 60898-1. Part of the Eaton Moeller xPole series for residential and commercial switchgear applications.