Schneider C16F44V100 Circuit Breaker (MCCB), ComPact NSX160F, 36kA/415VAC 4P Mic
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric C16F44V100 is a 4-pole ComPact NSX160F molded case circuit breaker (MCCB) with integrated Class A residual current protection, equipped with the electronic MicroLogic Vigi 4.2 protection unit. Rated at 100 A and 440 V AC, it delivers an ultimate breaking capacity of 36 kA at 380/415 V AC for demanding power distribution duties. Adjustable earth-leakage sensitivity from 30 mA to 5 A and selectable time delays enable precise selective coordination.
Technical specifications:
- Commercial reference: C16F44V100
- Manufacturer: Schneider Electric
- EAN:
- Series / range: ComPact NSX new generation
- Device short name: NSX160F
- Product type: Circuit breaker with integrated residual current protection
- Number of poles: 4P
- Rated current [In]: 100 A at 40°C
- Rated voltage [Ue]: 440 V AC 50/60 Hz
- Network type: AC, 50/60 Hz
- Ultimate breaking capacity [Icu]: 85 kA at 220/240 V AC / 36 kA at 380/415 V AC / 8 kA at 660/690 V AC (IEC 60947-2)
- Performance level: F - 36 kA at 415 V AC
- Protection unit: MicroLogic 4.2, electronic, LSoIR functions
- Long-time pick-up [Ir] adjustment range: 40-100 A (9 settings, adjustable)
- Short-time pick-up [Isd] adjustment range: 1.5-10 x Ir (adjustable)
- Instantaneous pick-up [Ii]: 1500 A (fixed)
- Earth-leakage sensitivity [In]: 30 mA / 100 mA / 300 mA / 500 mA / 1 A / 3 A / 5 A (adjustable)
- Earth-leakage time delay [t]: 0 / 60 / 150 / 500 ms / 1 s (adjustable)
- Differential protection class: Class A
- Thermal memory: 20 minutes before and after tripping
- Rated insulation voltage [Ui]: 500 V AC
- Rated impulse withstand voltage [Uimp]: 8 kV
- Mechanical / electrical durability: 40,000 cycles
- Mounting: Fixed, back plate
- Connection: Front upper and lower, 35 mm
- Slots for electrical auxiliaries: 5
- Dimensions (W x H x D): 140 x 161 x 86 mm
- Weight: 2.6 kg
- IP rating: IP40 (IEC 60529)
- IK rating: IK07 (IEC 62262)
- Operating temperature: -25 to 70°C
- Storage temperature: -50 to 85°C
- Operating altitude: up to 2000 m without derating; up to 5000 m with derating
- Standard: EN/IEC 60947-2
- Usage category: Category A
- Pollution degree: 3 (IEC 60664-1)
Features and benefits:
- Integrated Class A residual current protection with sensitivity adjustable from 30 mA to 5 A and time delay from 0 to 1 s, enabling selective coordination without an external RCD.
- Electronic MicroLogic 4.2 unit provides LSoIR protection: long-time overload, short-time short-circuit with fixed delay, instantaneous, and residual current - all in one device.
- Long-time pick-up Ir adjustable across 9 steps from 40 to 100 A with 20-minute thermal memory for accurate repeated overload management.
- Five slots for electrical auxiliaries allow integration of signaling, remote tripping, or monitoring accessories to suit panel requirements.
- Local LED indicators for device-ready (green flashing), 90% Ir warning (orange), and 105% Ir alarm (red) give at-a-glance status without opening the panel.
Applications:
- Main and sub-distribution boards in commercial and industrial installations requiring combined overload, short-circuit, and earth fault protection on a single 4-pole device.
- Industrial switchgear assemblies with prospective short-circuit currents up to 36 kA at 415 V AC.
- Power distribution systems where selective earth-leakage coordination is achieved using the adjustable time delay settings.
- Fixed-mounted low-voltage switchgear operating at voltages up to 440 V AC in buildings, factories, and infrastructure projects.
Compliant with EN/IEC 60947-2. Part of the Schneider Electric ComPact NSX new generation range.