{"title":"Circuit Protection","description":"\u003cp\u003eExplore our selection of \u003cstrong\u003eCircuit Protection\u003c\/strong\u003e solutions, offering premium products designed to safeguard electrical systems and ensure reliable operation. Sourced from the world’s most trusted brands, these products meet the highest standards of quality and performance.\u003c\/p\u003e\n\u003cp\u003eFrom overcurrent and earth fault protection to surge protection and power distribution, our in-stock options are ideal for residential, commercial, and industrial applications. With worldwide shipping available, you can trust us to keep your projects on schedule and secure.\u003c\/p\u003e","products":[{"product_id":"18637-miniature-circuit-breaker-mcb-acti9-ng125n-3p-40a-c-curve-25ka-iec-en-60947-2","title":"Schneider 18637 Miniature circuit breaker (MCB)","description":"\u003cp\u003eSchneider Electric 18637 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 NG125N range, rated at 40 A with a C tripping curve and a breaking capacity of 25 kA at 380-415 V AC per IEC 60947-2. Designed for electrical power distribution, it supports both AC and DC networks with thermomagnetic protection technology.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 18637\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 NG125\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: NG125N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A at 40°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 50 kA at 220-240 V AC; 25 kA at 380-415 V AC; 20 kA at 440 V AC; 10 kA at 500 V AC; 20 kA at up to 375 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 37.5 kA (220-240 V AC); 18.75 kA (380-415 V AC); 15 kA (440 V AC); 7.5 kA (500 V AC)\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 220-240 V \/ 380-415 V \/ 440 V \/ 500 V AC 50\/60 Hz; up to 375 V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 8 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eIK protection: IK05 (EN\/IEC 62262)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -30 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 70°C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm symmetrical DIN rail, click-on\u003c\/li\u003e\n  \u003cli\u003eHandle position: Vertical\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel terminals 1.5-50 mm² (rigid); 1-35 mm² (flexible)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStrip length: 20 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 81 x 103 x 81 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.72 kg\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eBusbar comb rail compatible: Yes (9 mm pitch)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh breaking capacity of 25 kA at 380-415 V AC suitable for demanding industrial and commercial installations\u003c\/li\u003e\n  \u003cli\u003eDual AC\/DC network compatibility provides flexibility across a wide range of electrical systems\u003c\/li\u003e\n  \u003cli\u003eIntegrated locking preparation allows the handle to be padlocked in the OFF position for safe isolation\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator enable quick visual status checks\u003c\/li\u003e\n  \u003cli\u003eClick-on DIN rail mounting and comb busbar compatibility simplify panel assembly\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-30 to 70°C) suits both indoor and harsh-environment enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal and sub-distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in main distribution panels\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery storage installations\u003c\/li\u003e\n  \u003cli\u003eMotor and equipment protection in industrial automation panels\u003c\/li\u003e\n  \u003cli\u003eHigh-fault-level environments requiring elevated breaking capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 NG125 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 18637, Schneider Electric 18637, Schneider NG125N 40A 3P MCB, Acti9 NG125N 40A circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065313718536,"sku":"SCH18637","price":92.21,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/18637-miniature-circuit-breaker-mcb-acti9-ng125n-3p-40a-c-curve-25ka-iecen-60947-2-162200.jpg?v=1735224427"},{"product_id":"28900-switch-disconnector-compact-ins40-40-a-standard-version-with-black-rotary-handle-3-poles","title":"Schneider 28900 switch disconnector","description":"\u003cp\u003eThe Schneider Electric 28900 is a 3-pole Compact INS40 switch disconnector rated at 40 A, designed for isolation and switching of AC and DC circuits. It provides safe electrical isolation with contact position indication and suits applications requiring reliable load disconnection. The device operates across a wide voltage range up to 500 V AC and 125 V DC.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 28900\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Compact INS\u003c\/li\u003e\n  \u003cli\u003eProduct group: Compact\u003c\/li\u003e\n  \u003cli\u003eProduct type: Switch disconnector\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated current (AC-22A): 40 A at 220\/240 V, 380\/415 V, 440\/480 V, 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated current (AC-23A): 40 A at 220\/240 V, 380\/415 V, 440\/480 V AC; 32 A at 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated current (DC-22A\/DC-23A): 40 A at 125 V DC (2 poles in series)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 8 kV\u003c\/li\u003e\n  \u003cli\u003eThermal current [Ith]: 40 A at 60°C\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit making capacity [Icm]: 15 kA (standalone) \/ 75 kA (with protective breaker) at 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current [Icw]: 3 kA for 1 s \/ 1.73 kA for 3 s \/ 0.67 kA for 20 s \/ 0.55 kA for 30 s per IEC 60947-3\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 500 V AC 50\/60 Hz \/ 125 V DC\u003c\/li\u003e\n  \u003cli\u003eMaximum power (AC-23): 22 kW at 440 V \/ 20 kW at 380\/415 V \/ 18.5 kW at 500\/525 V \/ 11 kW at 220\/240 V AC\u003c\/li\u003e\n  \u003cli\u003eCable cross-section: 1.5 - 50 mm²\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 1,500 cycles (AC-22A and AC-23A across all voltages)\u003c\/li\u003e\n  \u003cli\u003eControl type: Rotary handle\u003c\/li\u003e\n  \u003cli\u003eHandle colour: Black\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed\u003c\/li\u003e\n  \u003cli\u003eMounting support: DIN rail \/ panel\u003c\/li\u003e\n  \u003cli\u003eTerminal connection (top\/bottom): Front\u003c\/li\u003e\n  \u003cli\u003eWidth: 90 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 62.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP40 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eIK protection: IK07 per EN 50102\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -50 to 85°C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eCertifications: KEMA-KEUR, CCC\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-1, IEC 60947-3\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eContact position indicator provides clear visual confirmation of open or closed state\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation duty, enabling safe maintenance disconnection of circuits\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks for versatile panel integration\u003c\/li\u003e\n  \u003cli\u003eHigh short-circuit making capacity of 75 kA when used with a protective circuit breaker\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-25 to 70°C) supports harsh industrial environments\u003c\/li\u003e\n  \u003cli\u003eDIN rail and panel mounting options allow flexible installation in enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial control panels requiring safe isolation of motor or load circuits up to 40 A\u003c\/li\u003e\n  \u003cli\u003eMain or sub-distribution boards in commercial and light industrial installations\u003c\/li\u003e\n  \u003cli\u003eMachine building applications where visible disconnection and load switching are required\u003c\/li\u003e\n  \u003cli\u003eDC circuit isolation in photovoltaic or battery-backed systems at 125 V DC\u003c\/li\u003e\n  \u003cli\u003eSwitchgear assemblies requiring IEC 60947-3 compliant disconnector devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-1 and IEC 60947-3. Part of the Schneider Electric Compact INS range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 28900, Schneider Electric 28900, Compact INS40 switch disconnector, 40 A 3-pole disconnector.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065314275592,"sku":"SCH28900","price":40.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/28900-switch-disconnector-compact-ins40-40-a-standard-version-with-black-rotary-handle-3-poles-129297.jpg?v=1735225499"},{"product_id":"28902-switch-disconnector-compact-ins63-63-a-standard-version-with-black-rotary-handle-3-poles","title":"Schneider 28902 switch disconnector","description":"\u003cp\u003eThe Schneider Electric 28902 is a Compact INS63 3-pole switch disconnector rated at 63 A, designed to safely isolate AC and DC electrical circuits. With a rated insulation voltage of 690 V AC and an impulse withstand voltage of 8 kV, it suits demanding industrial distribution and control applications. A contact position indicator and rotary handle provide clear status feedback and reliable manual operation.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 28902\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Compact INS\u003c\/li\u003e\n  \u003cli\u003eProduct type: Switch disconnector\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated current [Ie]: 63 A AC-22A\/AC-23A at 220\/240 V, 380\/415 V, 440\/480 V; 40 A AC-23A at 500 V\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 500 V AC 50\/60 Hz; 125 V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 8 kV\u003c\/li\u003e\n  \u003cli\u003ePermissible thermal current [Ith]: 63 A at 60°C\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit making capacity [Icm]: 15 kA standalone \/ 75 kA with protective circuit breaker at 500 V AC\u003c\/li\u003e\n  \u003cli\u003eCable cross-section: 1.5...50 mm²\u003c\/li\u003e\n  \u003cli\u003eMaximum power (AC-23): 30 kW at 380\/415 V AC\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eControl type: Rotary handle (black)\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed; panel or DIN rail\u003c\/li\u003e\n  \u003cli\u003eTerminal connection: Front (upper and lower)\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 90 x 85 x 62.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP40 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eIK protection: IK07 (EN 50102)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -50...85°C\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-1, IEC 60947-3\u003c\/li\u003e\n  \u003cli\u003eCertifications: CCC, KEMA-KEUR\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation duty, enabling safe circuit disconnection for maintenance and servicing\u003c\/li\u003e\n  \u003cli\u003eContact position indicator provides visual confirmation of open or closed switch state\u003c\/li\u003e\n  \u003cli\u003eWide cable acceptance from 1.5 to 50 mm² supports flexible panel wiring configurations\u003c\/li\u003e\n  \u003cli\u003eHigh short-circuit making capacity of 75 kA when used with a protective circuit breaker\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks for versatile installation across different system types\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain supply isolation in industrial control panels and distribution boards\u003c\/li\u003e\n  \u003cli\u003eMotor feeder circuit isolation in manufacturing and process automation\u003c\/li\u003e\n  \u003cli\u003eGeneral AC distribution isolation in commercial and industrial buildings up to 500 V\u003c\/li\u003e\n  \u003cli\u003ePanel or DIN rail installations requiring reliable 63 A manual isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-1 and IEC 60947-3. Part of the Schneider Electric Compact INS range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 28902, Schneider Electric 28902, INS63 3P switch disconnector, Compact INS 63A disconnector.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065314406664,"sku":"SCH28902","price":30.48,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/28902-switch-disconnector-compact-ins63-63-a-standard-version-with-black-rotary-handle-3-poles-607394.jpg?v=1735225499"},{"product_id":"28904-switch-disconnector-compact-ins80-80-a-standard-version-with-black-rotary-handle-3-poles","title":"Schneider 28904 switch disconnector","description":"\u003cp\u003eThe Schneider Electric 28904 is a Compact INS80 3-pole switch disconnector rated at 80 A, designed for safe isolation of electrical circuits in AC and DC networks. With a rated insulation voltage of 690 V AC and an impulse withstand voltage of 8 kV, it provides reliable disconnection for industrial and commercial power distribution applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 28904\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Compact INS\u003c\/li\u003e\n  \u003cli\u003eProduct type: Switch disconnector\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated current (AC-22A): 80 A at 220\/240 V, 380\/415 V, 440\/480 V, 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated current (AC-23A): 80 A at 220\/240 V; 72 A at 380\/415 V; 63 A at 440\/480 V; 40 A at 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated current (DC-22A \/ DC-23A): 80 A at 125 V DC (2 poles in series)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 8 kV\u003c\/li\u003e\n  \u003cli\u003eConventional free-air thermal current [Ith]: 80 A at 60°C\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit making capacity [Icm]: 15 kA (disconnector alone, 500 V AC); 75 kA (with protective circuit breaker, 500 V AC)\u003c\/li\u003e\n  \u003cli\u003eShort-time withstand current [Icw]: 3 kA for 1 s; 1.73 kA for 3 s; 0.67 kA for 20 s; 0.55 kA for 30 s (per IEC 60947-3)\u003c\/li\u003e\n  \u003cli\u003eMaximum power (AC-23): 37 kW at 380\/415 V and 440 V; 22 kW at 220\/240 V and 500\/525 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eCable cross-section: 1.5...50 mm²\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 operating cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 1,500 cycles (AC-22A and AC-23A at all rated voltages)\u003c\/li\u003e\n  \u003cli\u003eControl type: Rotary handle (black)\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, on DIN rail or mounting plate\u003c\/li\u003e\n  \u003cli\u003eConnection: Front upper and front lower terminals\u003c\/li\u003e\n  \u003cli\u003eWidth: 90 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 62.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP40 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eIK protection rating: IK07 per EN 50102\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -50...85°C\u003c\/li\u003e\n  \u003cli\u003eCertifications: CCC, KEMA-KEUR\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-3, IEC 60947-1\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation duty - safely isolates circuits for maintenance and testing\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks, offering flexibility across installation types\u003c\/li\u003e\n  \u003cli\u003eHigh short-circuit making capacity of up to 75 kA when used with a protective circuit breaker\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25...70°C supports use in demanding environments\u003c\/li\u003e\n  \u003cli\u003eDIN rail and panel mounting options simplify installation in standard enclosures\u003c\/li\u003e\n  \u003cli\u003eContact position indicator provides clear visual confirmation of open or closed state\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eIsolation of motor circuits and industrial machinery in manufacturing plants\u003c\/li\u003e\n  \u003cli\u003eMain or section isolators in commercial and industrial power distribution boards\u003c\/li\u003e\n  \u003cli\u003eDC circuit disconnection in renewable energy or battery system installations\u003c\/li\u003e\n  \u003cli\u003eIsolation switching in automation panels and machine control cabinets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-3 and IEC 60947-1. Part of the Schneider Electric Compact INS range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 28904, Schneider Electric 28904, Compact INS80 switch disconnector, 80A 3-pole disconnector.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065314537736,"sku":"SCH28904","price":42.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/28904-switch-disconnector-compact-ins80-80-a-standard-version-with-black-rotary-handle-3-poles-771385.jpg?v=1735225496"},{"product_id":"28908-switch-disconnector-compact-ins100-100-a-standard-version-with-black-rotary-handle-3-poles","title":"Schneider 28908 switch disconnector","description":"\u003cp\u003eThe Schneider Electric 28908 is a 3-pole Compact INS100 switch disconnector rated at 100 A, designed for safe isolation of AC and DC circuits in industrial and commercial electrical installations. It supports rated voltages up to 690 V AC and 125 V DC, with a rated insulation voltage of 800 V AC and a withstand impulse voltage of 8 kV.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 28908\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Compact INS\u003c\/li\u003e\n  \u003cli\u003eProduct type: Switch disconnector\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated current (AC-22A): 100 A at 220\/240 V, 380\/415 V, 440\/480 V, 500 V, 660\/690 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated current (AC-23A): 100 A up to 500 V; 63 A at 660\/690 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated current (DC-22A \/ DC-23A): 100 A at 125 V DC (2 poles in series)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 800 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 8 kV\u003c\/li\u003e\n  \u003cli\u003eThermal current in air [Ith]: 100 A at 60 °C\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit making capacity [Icm]: 154 kA with circuit breaker at 690 V AC; 20 kA stand-alone at 690 V AC\u003c\/li\u003e\n  \u003cli\u003eShort-time withstand current [Icw]: 5.5 kA for 1 s; 3.175 kA for 3 s; 1.23 kA for 20 s; 1 kA for 30 s (IEC 60947-3)\u003c\/li\u003e\n  \u003cli\u003eMaximum power (AC-23): 22 kW at 220\/240 V; 45 kW at 380\/415 V; 55 kW at 440-690 V AC\u003c\/li\u003e\n  \u003cli\u003eRated duty cycle: Continuous\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 15,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 1,500 cycles (AC-22A and AC-23A at all rated voltages)\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, on plate or DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Front (top and bottom)\u003c\/li\u003e\n  \u003cli\u003eControl type: Rotary handle (black)\u003c\/li\u003e\n  \u003cli\u003eDimensions (HxWxD): 100 x 135 x 62.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.8 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP40 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eIK protection: IK07 (EN 50102)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -50...85 °C\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-3, IEC 60947-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: CCC, KEMA-KEUR\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation duty, with clear contact position indicator\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks across a wide voltage range up to 690 V AC\u003c\/li\u003e\n  \u003cli\u003eHigh short-circuit making capacity of 154 kA when combined with a circuit breaker\u003c\/li\u003e\n  \u003cli\u003eFlexible mounting on DIN rail or mounting plate with front connection terminals\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25 to 70 °C for demanding industrial environments\u003c\/li\u003e\n  \u003cli\u003eIP40 enclosure protection with IK07 mechanical impact resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain or sub-circuit isolation in industrial control panels and distribution boards\u003c\/li\u003e\n  \u003cli\u003eMotor feeder disconnection in machinery and process automation systems\u003c\/li\u003e\n  \u003cli\u003eSafe isolation in commercial and industrial AC distribution up to 690 V\u003c\/li\u003e\n  \u003cli\u003eDC circuit isolation in photovoltaic or battery systems at 125 V DC (2 poles in series)\u003c\/li\u003e\n  \u003cli\u003eLoad disconnection and maintenance isolation in manufacturing facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-3 and IEC 60947-1. Part of the Schneider Electric Compact INS range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 28908, Schneider Electric 28908, Compact INS100 switch disconnector, 100 A 3-pole isolator switch.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065314668808,"sku":"SCH28908","price":51.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/28908-switch-disconnector-compact-ins100-100-a-standard-version-with-black-rotary-handle-3-poles-266729.jpg?v=1735225497"},{"product_id":"28910-switch-disconnector-compact-ins125-125-a-standard-version-with-black-rotary-handle-3-poles","title":"Schneider 28910 switch disconnector","description":"\u003cp\u003eThe Schneider Electric 28910 is a Compact INS125 3-pole switch disconnector rated at 125 A, designed to safely isolate electrical circuits in industrial and commercial power distribution systems. It operates on both AC networks up to 690 V (50\/60 Hz) and DC circuits, with a rated insulation voltage of 800 V AC and a rated impulse withstand voltage of 8 kV.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 28910\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Compact INS (Compact group)\u003c\/li\u003e\n  \u003cli\u003eProduct type: Switch disconnector\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated current (Ie): AC-22A 125 A at 220\/240 V to 690 V AC; AC-23A 125 A up to 500 V AC, 80 A at 660\/690 V AC; DC-22A\/DC-23A 125 A at 125 V DC (2 poles in series)\u003c\/li\u003e\n  \u003cli\u003eRated voltage (Ue): 690 V AC 50\/60 Hz; 125 V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 800 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 8 kV\u003c\/li\u003e\n  \u003cli\u003eConventional thermal current (Ith): 125 A at 60°C\u003c\/li\u003e\n  \u003cli\u003eMaking capacity (Icm): 20 kA standalone \/ 154 kA with protective circuit breaker at 690 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eShort-time withstand current (Icw): 5.5 kA for 1 s \/ 3.175 kA for 3 s \/ 1.23 kA for 20 s \/ 1 kA for 30 s per IEC 60947-3\u003c\/li\u003e\n  \u003cli\u003eMaximum switched power (AC-23): 75 kW at 660\/690 V AC; 75 kW at 500\/525 V AC; 55 kW at 380\/415 V and 440 V AC; 37 kW at 220\/240 V AC\u003c\/li\u003e\n  \u003cli\u003eRated duty: Continuous; intermittent duty class 120 - 60%\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 15,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 1,500 cycles at AC-22A and AC-23A across all rated voltages\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation: Yes\u003c\/li\u003e\n  \u003cli\u003eContact position indicator: Yes\u003c\/li\u003e\n  \u003cli\u003eVisible break: No\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eControl type: Rotary handle (black)\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed; DIN rail or panel\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Front upper and front lower\u003c\/li\u003e\n  \u003cli\u003eConnection spacing: 30 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 135 x 100 x 62.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.8 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP40 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eIK protection: IK07 per EN 50102\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -50 to 85°C\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-1, IEC 60947-3\u003c\/li\u003e\n  \u003cli\u003eCertifications: CCC, KEMA-KEUR\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eApproved for use as an isolator, enabling safe maintenance isolation of downstream circuits\u003c\/li\u003e\n  \u003cli\u003eIntegrated contact position indicator gives clear visual confirmation of switch state\u003c\/li\u003e\n  \u003cli\u003eRated for AC networks up to 690 V and DC circuits, covering a broad range of installation types\u003c\/li\u003e\n  \u003cli\u003eFixed-mount design accommodates both DIN rail and panel mounting for flexible installation\u003c\/li\u003e\n  \u003cli\u003eHigh mechanical endurance of 15,000 cycles ensures long service life in demanding applications\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25 to 70°C suits harsh industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain isolation duty in industrial power distribution and switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eMotor circuit isolation and safe maintenance switching in machine building\u003c\/li\u003e\n  \u003cli\u003eIsolation switching in commercial and industrial electrical distribution boards\u003c\/li\u003e\n  \u003cli\u003eAC and DC power system isolation in automation and process control panels\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty isolation in controlgear and busbar-fed distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-1 and IEC 60947-3. Part of the Schneider Electric Compact INS range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 28910, Schneider Electric 28910, Compact INS125 switch disconnector, 125 A 3-pole isolator switch.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065314930952,"sku":"SCH28910","price":55.37,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/28910-switch-disconnector-compact-ins125-125-a-standard-version-with-black-rotary-handle-3-poles-470846.jpg?v=1735225495"},{"product_id":"28912-switch-disconnector-compact-ins160-160-a-standard-version-with-black-rotary-handle-3-poles","title":"Schneider 28912 switch disconnector","description":"\u003cp\u003eThe Schneider Electric 28912 is a 3-pole switch disconnector from the Compact INS range, rated at 160 A for AC networks up to 690 V and DC networks at 125 V. Designed for safe circuit isolation in industrial applications, it uses a rotary handle mechanism and supports mounting on DIN rail or a fixed plate.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 28912\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Compact INS\u003c\/li\u003e\n  \u003cli\u003eProduct type: Switch disconnector\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current [Ie]: 160 A AC-22A\/AC-23A; 160 A DC-22A at 125 V DC\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 690 V AC 50\/60 Hz; 125 V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 800 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 8 kV\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit making capacity [Icm]: 154 kA (with protective breaker, 690 V AC); 20 kA (standalone, 690 V AC)\u003c\/li\u003e\n  \u003cli\u003eThermal current in air [Ith]: 160 A at 60°C\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 15,000 cycles\u003c\/li\u003e\n  \u003cli\u003eControl type: Rotary handle (black)\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail or plate\u003c\/li\u003e\n  \u003cli\u003eConnection: Front (upper and lower), 30 mm\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP40 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eIK protection: IK07 (EN 50102)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 135 x 100 x 62.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.8 kg\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-3, IEC 60947-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: CCC, KEMA-KEUR\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for both AC networks (up to 690 V) and DC networks (125 V), offering broad application flexibility\u003c\/li\u003e\n  \u003cli\u003eContact position indicator provides clear visual confirmation of the open or closed circuit state\u003c\/li\u003e\n  \u003cli\u003eHigh rated short-circuit making capacity of 154 kA when used with a protective circuit breaker\u003c\/li\u003e\n  \u003cli\u003eRated for 15,000 mechanical cycles, ensuring long-term reliable operation in demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain isolator in industrial control panels and motor control centers\u003c\/li\u003e\n  \u003cli\u003eSafe circuit disconnection during maintenance on installations up to 690 V AC\u003c\/li\u003e\n  \u003cli\u003eDC circuit isolation in industrial systems operating at 125 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-3 and IEC 60947-1. Part of the Schneider Electric Compact INS range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 28912, Schneider Electric 28912, Compact INS160 switch disconnector, 160 A isolator switch.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065315160328,"sku":"SCH28912","price":76.31,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/28912-switch-disconnector-compact-ins160-160-a-standard-version-with-black-rotary-handle-3-poles-752487.jpg?v=1735225495"},{"product_id":"28943-right-side-rotary-handle-ins-40-160-black-handle","title":"Schneider 28943 Right side rotary handle INS 40..160 - black handle","description":"\u003cp\u003eThe Schneider Electric 28943 is a right-side rotary handle accessory for the INS 40 to 160 switch range. Featuring an extended arm in lateral mounting configuration, it provides ergonomic panel door operation with a black handle and matching black front plate. The handle locks in the OFF position, supporting safe isolation and lockout procedures.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 28943\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: INS40...160\u003c\/li\u003e\n  \u003cli\u003eProduct type: Rotary handle accessory\u003c\/li\u003e\n  \u003cli\u003eAccessory type: Accessory\u003c\/li\u003e\n  \u003cli\u003eHandle color: Black\u003c\/li\u003e\n  \u003cli\u003eFront plate color: Black\u003c\/li\u003e\n  \u003cli\u003eMounting type: Extended\u003c\/li\u003e\n  \u003cli\u003eHandle position: Lateral (side-mounted)\u003c\/li\u003e\n  \u003cli\u003eLocking: Lockable in OFF position\u003c\/li\u003e\n  \u003cli\u003eUnit weight: 258 g\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRight-side lateral mounting suits panel door assemblies where the switch must be operated from the side\u003c\/li\u003e\n  \u003cli\u003eExtended rotary arm provides comfortable reach and controlled switch operation\u003c\/li\u003e\n  \u003cli\u003eLockable in the OFF position to support lockout\/tagout safety and maintenance isolation\u003c\/li\u003e\n  \u003cli\u003eBlack handle and black front plate give a consistent, professional appearance to panel doors\u003c\/li\u003e\n  \u003cli\u003eDedicated accessory engineered specifically for INS 40 to 160 series switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial switchgear and distribution panels requiring rotary door-mounted switch operation\u003c\/li\u003e\n  \u003cli\u003eMotor control centers and machine control enclosures\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial electrical installations with lockout\/tagout safety requirements\u003c\/li\u003e\n  \u003cli\u003ePanel assemblies where lateral access to INS series switches is necessary\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePart of the Schneider Electric INS40...160 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 28943, Schneider Electric 28943, rotary handle INS 40-160, extended side rotary handle black.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065315324168,"sku":"SCH28943","price":19.26,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/28943-right-side-rotary-handle-ins-40160-black-handle-807245.jpg?v=1735225494"},{"product_id":"28949-terminal-blocks-4-x-25-mm2-set-of-3","title":"Schneider 28949 Terminal Block 4x25mm2 Power Connection Set 3","description":"\u003cp\u003eThe Schneider Electric 28949 is a cable connector set for 4 x 25 mm² cables, supplied as a set of 3. This power connection accessory is compatible with the Compact INS and Compact INSE circuit breaker ranges, supporting rated currents from 0 to 160 A. It is designed to provide secure, reliable cable termination in low-voltage distribution and control panel applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 28949\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Compact INS, Compact INSE\u003c\/li\u003e\n  \u003cli\u003eProduct type: Cable connector (connection accessory)\u003c\/li\u003e\n  \u003cli\u003eCable cross-section: 4 x 25 mm²\u003c\/li\u003e\n  \u003cli\u003eQuantity per set: 3\u003c\/li\u003e\n  \u003cli\u003eRated current: 0-160 A\u003c\/li\u003e\n  \u003cli\u003eUnit package weight: 126 g\u003c\/li\u003e\n  \u003cli\u003eUnit package dimensions (HxWxL): 3 x 12 x 20 cm\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned for direct compatibility with Compact INS and Compact INSE circuit breakers, ensuring correct fit and performance\u003c\/li\u003e\n  \u003cli\u003eAccepts cable cross-sections up to 4 x 25 mm², suitable for high-current power cable termination\u003c\/li\u003e\n  \u003cli\u003eSupplied as a set of 3, reducing sourcing time and ensuring matched components for three-phase installations\u003c\/li\u003e\n  \u003cli\u003eRated for currents from 0 to 160 A, covering a broad range of distribution requirements\u003c\/li\u003e\n  \u003cli\u003eRoHS compliant - free of toxic heavy metals and mercury\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cable termination on Compact INS and Compact INSE series circuit breakers\u003c\/li\u003e\n  \u003cli\u003eIncoming supply cable connection in industrial and commercial low-voltage distribution boards\u003c\/li\u003e\n  \u003cli\u003eThree-phase panel assembly requiring 25 mm² cable terminations rated to 160 A\u003c\/li\u003e\n  \u003cli\u003eSwitchgear and control panel wiring where matched accessory sets are required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRoHS compliant with exceptions. Part of the Schneider Electric Compact range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 28949, Schneider Electric 28949, Compact INS cable connector set, 25mm2 terminal connection accessory.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065315848456,"sku":"SCH28949","price":31.66,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/28949-terminal-blocks-4-x-25-mm2-set-of-3-256769.jpg?v=1735225495"},{"product_id":"28957-terminal-shields-compact-ins40-to-80-insulation-accessories-3-and-4-poles-set-of-2-parts","title":"Schneider 28957 Terminal Shield for Distribution Boards","description":"\u003cp\u003eThe Schneider Electric 28957 is a terminal cover accessory for the Compact INS range, supplied as a set of 2 covers compatible with 3P and 4P configurations on INS40 to INS80 switches. Designed as an installation accessory, it provides IP40 protection to exposed connection terminals, reducing the risk of accidental contact in distribution board assemblies.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 28957\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Compact INS\u003c\/li\u003e\n  \u003cli\u003eProduct type: Terminal cover\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P \/ 4P\u003c\/li\u003e\n  \u003cli\u003eCompatible with: Compact INS40 to INS80\u003c\/li\u003e\n  \u003cli\u003eQuantity per set: 2\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP40\u003c\/li\u003e\n  \u003cli\u003ePackage weight: 72.0 g\u003c\/li\u003e\n  \u003cli\u003ePackage dimensions: 78 x 40 x 62 mm\u003c\/li\u003e\n  \u003cli\u003ePVC-free: Yes\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides IP40 protection to exposed connection terminals on Compact INS switches\u003c\/li\u003e\n  \u003cli\u003eCompatible with both 3P and 4P pole configurations in a single set\u003c\/li\u003e\n  \u003cli\u003eCovers the full INS40 to INS80 model range within the Compact INS family\u003c\/li\u003e\n  \u003cli\u003eSupplied as a set of 2 covers for straightforward panel installation\u003c\/li\u003e\n  \u003cli\u003ePVC-free construction in line with Schneider Electric environmental commitments\u003c\/li\u003e\n  \u003cli\u003eLightweight at 72.0 g per set, minimising added load in panel assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eTerminal protection in low-voltage distribution boards and switchgear enclosures\u003c\/li\u003e\n  \u003cli\u003eIndustrial and commercial electrical panel assemblies using Compact INS switches\u003c\/li\u003e\n  \u003cli\u003eInstallation alongside INS40 to INS80 disconnector switches requiring IP40 terminal shielding\u003c\/li\u003e\n  \u003cli\u003eSwitchgear build-outs where exposed terminal safety compliance is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInstallation accessory for the Schneider Electric Compact INS range. Part of the Schneider Electric Compact product family.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 28957, Schneider Electric 28957, Compact INS terminal cover, INS terminal shield.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065315946760,"sku":"SCH28957","price":9.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/28957-terminal-shields-compact-ins40-to-80-insulation-accessories-3-and-4-poles-set-of-2-parts-614382.jpg?v=1735225495"},{"product_id":"29450-standard-auxiliary-contact-circuit-breaker-status-of-sd-sde-sdv-1-changeover-contact-type-screwless-spring-terminals","title":"Schneider 29450 standard auxiliary contact","description":"\u003cp\u003eThe Schneider Electric 29450 is a standard auxiliary contact carrying short device designations OF, SD, SDE, and SDV. It is designed for circuit breaker status monitoring and provides a 1 NO\/NC signal contact that installs via a click-on system. Compatible with the Compact NS, EasyPact CVS, and PowerPact Multistandard circuit breaker families, it delivers a permitted thermal current of 5 A.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 29450\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Compact NS \/ EasyPact CVS \/ PowerPact Multistandard\u003c\/li\u003e\n  \u003cli\u003eProduct type: Auxiliary contact\u003c\/li\u003e\n  \u003cli\u003eShort device designation: OF \/ SD \/ SDE \/ SDV\u003c\/li\u003e\n  \u003cli\u003eApplication: Circuit breaker status monitoring\u003c\/li\u003e\n  \u003cli\u003eSignal contact composition: 1 NO\/NC\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contact type: Standard\u003c\/li\u003e\n  \u003cli\u003eMounting: Click-on system\u003c\/li\u003e\n  \u003cli\u003ePermitted thermal current [Ith]: 5 A\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity AC-12: 6 A at 24 V to 660\/690 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity AC-15: 6 A at 24 V AC, 0.1 A at 660\/690 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity DC-12: 6 A at 24 V DC, 0.3 A at 250 V DC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity DC-14: 1 A at 24 V DC, 0.03 A at 250 V DC\u003c\/li\u003e\n  \u003cli\u003eMinimum load: 100 mA at 24 V DC\u003c\/li\u003e\n  \u003cli\u003eConnection terminal: Spring, 0.5...1.5 mm² (AWG 20 to AWG 16)\u003c\/li\u003e\n  \u003cli\u003eWeight: 16.9 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e1 NO\/NC contact for flexible open or closed circuit breaker status monitoring\u003c\/li\u003e\n  \u003cli\u003eClick-on mounting enables fast, tool-free installation onto compatible circuit breakers\u003c\/li\u003e\n  \u003cli\u003eLocal signalization with ON\/OFF status reading, fault trip indicator, and electrical fault indication\u003c\/li\u003e\n  \u003cli\u003eWide voltage coverage from 24 V to 690 V AC across AC-12 and AC-15 utilization categories\u003c\/li\u003e\n  \u003cli\u003eCompatible with Compact NS630b...1600, NS1600b...3200, NSX, INS, INV, and NSX DC variants\u003c\/li\u003e\n  \u003cli\u003eSpring connection terminals accept 0.5...1.5 mm² conductors for reliable, vibration-resistant wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eStatus monitoring of Compact NS630b to NS3200 molded case circuit breakers\u003c\/li\u003e\n  \u003cli\u003eAuxiliary signaling in Compact NSX and Compact NSX DC installations\u003c\/li\u003e\n  \u003cli\u003eIntegration with EasyPact CVS and PowerPact Multistandard circuit breaker assemblies\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring remote ON\/OFF and fault trip status signals\u003c\/li\u003e\n  \u003cli\u003eSpare part replacement for existing Compact NS630b...1600 and NS1600b...3200 assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EU RoHS directive and REACh regulation. Part of the Schneider Electric Compact NS and EasyPact CVS auxiliary accessory range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 29450, Schneider Electric 29450, Compact NS auxiliary contact, OF SD SDE SDV auxiliary contact.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065316372744,"sku":"SCH29450","price":13.88,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/29450-standard-auxiliary-contact-circuit-breaker-status-ofsdsdesdv-1-changeover-contact-type-screwless-spring-terminals-433737.jpg?v=1735225547"},{"product_id":"31053-extended-rotary-handle-front-control-compact-ins-inv-320-to-630-compact-insj400-red-handle-on-yellow-front","title":"Schneider 31053 extended rotary handle","description":"\u003cp\u003eThe Schneider Electric 31053 is a front-mounted extended rotary handle accessory for INS\/INV320...630 and INSJ400 series switches. Featuring a red handle and yellow front plate, it delivers clear visual status indication in panel installations. The handle supports locking in the OFF position, enabling safe isolation during maintenance.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 31053\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: INS320...630, INV320...630, INSJ400\u003c\/li\u003e\n  \u003cli\u003eProduct type: Rotary handle accessory\u003c\/li\u003e\n  \u003cli\u003eHandle color: Red\u003c\/li\u003e\n  \u003cli\u003eFront plate color: Yellow\u003c\/li\u003e\n  \u003cli\u003eMounting type: Extended, front-mounted\u003c\/li\u003e\n  \u003cli\u003eLocking position: Lockable in OFF position\u003c\/li\u003e\n  \u003cli\u003ePackage dimensions (L x W x H): 49.0 x 9.6 x 8.0 cm\u003c\/li\u003e\n  \u003cli\u003ePackage weight: 1.284 kg\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRed handle provides immediate visual identification of switch state on the panel front\u003c\/li\u003e\n  \u003cli\u003eYellow front plate ensures high-contrast visibility in distribution enclosures\u003c\/li\u003e\n  \u003cli\u003eExtended front-mounted design allows operation through enclosure doors\u003c\/li\u003e\n  \u003cli\u003eLockable in the OFF position to support safe isolation and lockout procedures\u003c\/li\u003e\n  \u003cli\u003ePurpose-built accessory for INS\/INV320...630 and INSJ400 series, ensuring correct fit and reliable operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial switchgear panels and distribution boards using INS\/INV320...630 switches\u003c\/li\u003e\n  \u003cli\u003eElectrical enclosures where switch actuation through a closed door is required\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring lockable isolation for maintenance and service access\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial control panels specifying the INSJ400 series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePart of the Schneider Electric INS\/INV320...630 and INSJ400 series accessories range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 31053, Schneider Electric 31053, Schneider rotary handle INS630, Schneider extended rotary handle accessory.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065317060872,"sku":"SCH31053","price":44.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/31053-extended-rotary-handle-front-control-compact-insinv-320-to-630-compact-insj400-red-handle-on-yellow-front-427991.jpg?v=1735225815"},{"product_id":"31106-switch-disconnector-compact-ins250-250-a-standard-version-with-black-rotary-handle-3-poles","title":"Schneider 31106 switch disconnector","description":"\u003cp\u003eThe Schneider Electric 31106 is a 3-pole Compact INS250 switch disconnector rated at 250 A, designed for safe isolation and load switching in industrial and commercial electrical installations. With a rated insulation voltage of 800 V AC and compatibility with both AC and DC networks, it covers a wide voltage range up to 690 V AC, making it suitable for demanding distribution applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 31106\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Compact INS\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current [Ie]: 250 A (AC-22A \/ AC-23A at 220\/240 V to 660\/690 V AC 50\/60 Hz; DC-22A \/ DC-23A at 125 V DC)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 800 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 690 V AC 50\/60 Hz \/ 125 V DC\u003c\/li\u003e\n  \u003cli\u003eThermal current [Ith]: 250 A at 60°C\u003c\/li\u003e\n  \u003cli\u003eMaking capacity [Icm]: 30 kA standalone \/ 330 kA with circuit breaker at 690 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eShort-time withstand current [Icw]: 8.5 kA for 1 s per IEC 60947-3\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 15,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 1,500 cycles\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail or panel\u003c\/li\u003e\n  \u003cli\u003eConnection: Front (upper and lower), 35 mm\u003c\/li\u003e\n  \u003cli\u003eControl: Direct front rotary handle (black)\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 140 x 136 x 96 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 2 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP40 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eIK protection: IK07 per EN 50102\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-3, IEC 60947-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: KEMA-KEUR, CCC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eApproved for isolation duty, enabling safe electrical disconnection of downstream circuits\u003c\/li\u003e\n  \u003cli\u003eBuilt-in contact position indicator for clear ON\/OFF status at a glance\u003c\/li\u003e\n  \u003cli\u003ePollution degree 3 rating ensures reliable performance in industrial environments\u003c\/li\u003e\n  \u003cli\u003eContinuous duty cycle supports uninterrupted load switching in distribution applications\u003c\/li\u003e\n  \u003cli\u003eHigh making capacity of 330 kA when used in combination with a circuit breaker\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC networks up to 690 V and DC applications at 125 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain switch disconnector in industrial distribution boards and motor control centers\u003c\/li\u003e\n  \u003cli\u003eIsolation of motor loads up to 210 kW at 660\/690 V AC\u003c\/li\u003e\n  \u003cli\u003eIncoming isolation in commercial and manufacturing facility control panels\u003c\/li\u003e\n  \u003cli\u003eMachine tool and automation system main disconnect\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-3 and IEC 60947-1. Part of the Schneider Electric Compact INS range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 31106, Schneider Electric 31106, Compact INS250 switch disconnector, 250 A 3-pole disconnector.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065317814536,"sku":"SCH31106","price":134.71,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/31106-switch-disconnector-compact-ins250-250-a-standard-version-with-black-rotary-handle-3-poles-1085532.jpg?v=1757426814"},{"product_id":"31108-switch-disconnector-compact-ins320-320-a-standard-version-with-black-rotary-handle-3-poles","title":"Schneider 31108 switch disconnector","description":"\u003cp\u003eThe Schneider Electric 31108 is a Compact INS320 3-pole switch disconnector rated at 320 A for AC systems up to 690 V and DC at 125 V, designed for safe circuit isolation in industrial power distribution and motor control panels. It features a direct front rotary handle and a contact position indicator for reliable operational status confirmation.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 31108\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Compact INS\u003c\/li\u003e\n  \u003cli\u003eProduct type: Switch disconnector\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated current [Ie]: 320 A AC-22A\/AC-23A (220-690 V AC); 320 A DC-22A\/DC-23A (125 V DC, 2 poles in series)\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 690 V AC 50\/60 Hz \/ 125 V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 800 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 8 kV (IEC 60947-3)\u003c\/li\u003e\n  \u003cli\u003eConventional thermal current [Ith]: 320 A at 60°C\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit making capacity [Icm]: 330 kA (with protective CB, 690 V AC) \/ 50 kA standalone\u003c\/li\u003e\n  \u003cli\u003eShort-time withstand current [Icw]: 20 kA for 1 s \/ 11.5 kA for 3 s (IEC 60947-3)\u003c\/li\u003e\n  \u003cli\u003eMaximum switched power: 250 kW at 660\/690 V AC (AC-23)\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eControl: Direct front rotary handle, black\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, plate or DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Front top and bottom, 45 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 185 x 205 x 120 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 4.6 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP40 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eIK protection: IK07 (EN 50102)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-1, IEC 60947-3\u003c\/li\u003e\n  \u003cli\u003eCertifications: CCC, KEMA-KEUR\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation: Yes\u003c\/li\u003e\n  \u003cli\u003eContact position indicator: Yes\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eApproved for safe isolation per IEC 60947-3, protecting personnel during maintenance and service\u003c\/li\u003e\n  \u003cli\u003eContact position indicator gives instant visual confirmation of open or closed circuit state\u003c\/li\u003e\n  \u003cli\u003e330 kA short-circuit making capacity (with protective CB) for demanding fault conditions\u003c\/li\u003e\n  \u003cli\u003eWide -25...70°C operating temperature range suitable for harsh industrial environments\u003c\/li\u003e\n  \u003cli\u003eFlexible installation on plate or DIN rail with front-access top and bottom connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain isolation switching in industrial switchboards and motor control centers\u003c\/li\u003e\n  \u003cli\u003ePower distribution panels in manufacturing plants and process control facilities\u003c\/li\u003e\n  \u003cli\u003eDisconnection of large motor loads up to 250 kW at 660\/690 V AC\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems at 125 V in industrial automation installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-1 and IEC 60947-3. Part of the Schneider Electric Compact INS range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 31108, Schneider Electric 31108, Compact INS320 switch disconnector, 320 A isolator switch.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065318076680,"sku":"SCH31108","price":227.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/31108-switch-disconnector-compact-ins320-320-a-standard-version-with-black-rotary-handle-3-poles-324231.jpg?v=1735225847"},{"product_id":"31110-switch-disconnector-compact-ins400-400-a-standard-version-with-black-rotary-handle-3-poles","title":"Schneider 31110 switch disconnector","description":"\u003cp\u003eThe Schneider Electric 31110 is the Compact INS400 3-pole switch disconnector rated at 400 A, designed for reliable circuit isolation in industrial power distribution and motor control applications. Operating on AC and DC networks up to 690 V AC at 50\/60 Hz, it features a rated insulation voltage of 800 V AC and a rated impulse withstand voltage of 8 kV.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 31110\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Compact INS\u003c\/li\u003e\n  \u003cli\u003eProduct type: Switch disconnector\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current: 400 A (AC-22A \/ AC-23A)\u003c\/li\u003e\n  \u003cli\u003eRated voltage: 690 V AC 50\/60 Hz \/ 125 V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 800 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 8 kV (IEC 60947-3)\u003c\/li\u003e\n  \u003cli\u003eShort-circuit making capacity: 330 kA with protective circuit breaker at 690 V AC \/ 50 kA standalone\u003c\/li\u003e\n  \u003cli\u003eShort-time withstand current: 20 kA for 1 s \/ 11.5 kA for 3 s (IEC 60947-3)\u003c\/li\u003e\n  \u003cli\u003eMaximum motor power: 400 kW at 660\/690 V AC (AC-23)\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 1,500 cycles at 690 V AC\u003c\/li\u003e\n  \u003cli\u003eControl type: Direct front rotary handle\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed - plate or DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Front terminals (top and bottom), 45 mm pitch\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 185 x 205 x 120 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 4.6 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP40 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eIK rating: IK07 (EN 50102)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -50...85°C\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-1, IEC 60947-3\u003c\/li\u003e\n  \u003cli\u003eCertifications: KEMA-KEUR, CCC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCertified for isolation duty per IEC 60947-3 for safe de-energisation of circuits\u003c\/li\u003e\n  \u003cli\u003eContact position indicator provides clear visual confirmation of open or closed state\u003c\/li\u003e\n  \u003cli\u003eHigh short-circuit making capacity of 330 kA when combined with a protective circuit breaker\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks at 50\/60 Hz across a wide voltage range\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25...70°C suited to demanding industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain circuit isolation in industrial distribution boards and motor control centres\u003c\/li\u003e\n  \u003cli\u003eDisconnection and isolation of large motors up to 400 kW at 690 V AC\u003c\/li\u003e\n  \u003cli\u003ePower isolation in switchgear panels and manufacturing plant installations\u003c\/li\u003e\n  \u003cli\u003eAC and DC circuit isolation in process plant electrical systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-1 and IEC 60947-3. Part of the Schneider Electric Compact INS range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 31110, Schneider Electric 31110, Compact INS400 switch disconnector, 400 A 3-pole disconnector.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065318437128,"sku":"SCH31110","price":198.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/31110-switch-disconnector-compact-ins400-400-a-standard-version-with-black-rotary-handle-3-poles-323585.jpg?v=1735225847"},{"product_id":"a9a26476-shunt-trip-release-acti9-imx-voltage-release-100-415-v-ac","title":"Schneider A9A26476 Acti9 iMX Shunt Trip Release 110-415 VAC","description":"\u003cp\u003eThe A9A26476 is an Acti9 iMX shunt trip release from Schneider Electric, designed to trip a compatible Acti9 circuit breaker remotely when a control voltage is applied to its coil.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9A26476\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: iMX\u003c\/li\u003e\n\u003cli\u003eType: Shunt trip release\u003c\/li\u003e\n\u003cli\u003eRated voltage: 110–415 VAC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065320665352,"sku":"SCHA9A26476","price":32.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9a26476-shunt-trip-release-acti9-imx-voltage-release-100415-v-ac-926357.jpg?v=1735229659"},{"product_id":"a9a26927-auxiliary-contact-acti9-isd-1oc-ac-dc","title":"Schneider A9A26927 Acti9 iSD Auxiliary Contact 1OC AC\/DC","description":"\u003cp\u003eThe Schneider Electric A9A26927 is an auxiliary contact for the Acti9 iSD (switch-disconnector) range, used to report contact position on AC or DC control circuits.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9A26927\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: iSD (switch-disconnector)\u003c\/li\u003e\n\u003cli\u003eType: Auxiliary contact\u003c\/li\u003e\n\u003cli\u003eContact configuration: 1OC (1 normally open contact)\u003c\/li\u003e\n\u003cli\u003eSupply compatibility: AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065321124104,"sku":"SCHA9A26927","price":7.77,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9a26927-auxiliary-contact-acti9-isd-1oc-acdc-228612.jpg?v=1735229659"},{"product_id":"a9d20610-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1p-n-10a-c-curve-6000a-ac-type-30ma","title":"Schneider A9D20610 Acti9 DPN Vigi K RCBO 1P+N C 10A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric Acti 9 DPN Vigi K (A9D20610) is a 1P+N residual current breaker with overcurrent protection (RCBO) from the Acti 9 range, combining earth-fault and overcurrent protection in a single device for final circuit protection in residential and commercial installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D20610\u003c\/li\u003e\n\u003cli\u003eModel: Acti 9 DPN Vigi K\u003c\/li\u003e\n\u003cli\u003eType: RCBO (residual current breaker with overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 10 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 220–240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA, type AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 220–240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065326006536,"sku":"SCHA9D20610","price":24.76,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9d20610-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1pn-10a-c-curve-6000a-ac-type-30ma-349862.jpg?v=1745440437"},{"product_id":"a9d20616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1p-n-16a-c-curve-6000a-ac-type-30ma","title":"Schneider A9D20616 Acti9 DPN Vigi K RCBO 1P+N C 16A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric Acti 9 A9D20616 DPN Vigi K is a 1P+N RCBO (residual current circuit breaker with integral overcurrent protection) from the Acti 9 range, providing combined protection of final circuits against overcurrents and earth faults in residential and commercial installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D20616\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: DPN Vigi K\u003c\/li\u003e\n\u003cli\u003eType: RCBO (residual current circuit breaker with overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 16 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 220–240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity (IdN): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 220–240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065326104840,"sku":"SCHA9D20616","price":27.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d20616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1pn-16a-c-curve-6000a-ac-type-30ma-630831.jpg?v=1735229809"},{"product_id":"a9d20620-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1p-n-20a-c-curve-6000a-ac-type-30ma","title":"Schneider A9D20620 Acti9 DPN Vigi K RCBO 1P+N C 20A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric Acti9 DPN Vigi K (A9D20620) is a 1P+N RCBO combining overcurrent and residual-current protection in a single device, part of the Acti 9 modular range for residential and commercial distribution boards.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D20620\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: DPN Vigi K\u003c\/li\u003e\n\u003cli\u003eType: RCBO (Residual Current Breaker with Overcurrent Protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 20 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 220–240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eResidual-current sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 220–240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065326235912,"sku":"SCHA9D20620","price":24.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d20620-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1pn-20a-c-curve-6000a-ac-type-30ma-953303.jpg?v=1735229810"},{"product_id":"a9d22616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1p-n-16a-b-curve-6000a-ac-type-30ma","title":"Schneider A9D22616 Acti9 DPN Vigi K RCBO 1P+N B 16A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric A9D22616 is a 1P+N RCBO (residual current circuit breaker with overcurrent protection) from the Acti 9 DPN Vigi K range, providing combined overload, short-circuit, and earth-fault protection on single-phase circuits in residential and commercial installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D22616\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: DPN Vigi K\u003c\/li\u003e\n\u003cli\u003eType: RCBO (residual current circuit breaker with overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 16 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: B\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 220...240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 220...240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065326399752,"sku":"SCHA9D22616","price":29.81,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d22616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1pn-16a-b-curve-6000a-ac-type-30ma-382724.jpg?v=1735229809"},{"product_id":"a9d22620-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1p-n-20a-b-curve-6000a-ac-type-30ma","title":"Schneider A9D22620 Acti9 DPN Vigi K RCBO 1P+N B 20A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric Acti9 DPN Vigi K (A9D22620) is a 1P+N RCBO that combines overcurrent protection and residual-current protection in a single module, for use in final circuits of single-phase 220–240 V AC domestic and light commercial installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D22620\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: DPN Vigi K\u003c\/li\u003e\n\u003cli\u003eType: RCBO (Residual Current Circuit Breaker with Overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 20 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: B\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 220...240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 220...240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065326498056,"sku":"SCHA9D22620","price":24.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d22620-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1pn-20a-b-curve-6000a-ac-type-30ma-526488.jpg?v=1735229811"},{"product_id":"a9d31606-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1p-n-6a-c-curve-6000a-ac-type-30ma","title":"Schneider A9D31606 Acti9 iDPN N Vigi RCBO 1P+N 6A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric A9D31606 is an Acti9 iDPN N Vigi RCBO (residual current circuit breaker with overcurrent protection), combining overload, short-circuit, and earth-leakage protection in a compact 1P+N format for single-phase circuits.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D31606\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: iDPN N Vigi\u003c\/li\u003e\n\u003cli\u003eType: RCBO (residual current circuit breaker with overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 6 A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 230–240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: Type AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230–240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065326661896,"sku":"SCHA9D31606","price":38.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d31606-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1pn-6a-c-curve-6000a-ac-type-30ma-519343.jpg?v=1735229811"},{"product_id":"a9d31610-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1p-n-10a-c-curve-6000a-ac-type-30ma","title":"Schneider A9D31610 Acti9 iDPN N Vigi RCBO 1P+N 10A 6kA 30mA AC","description":"\u003cp\u003eThe Schneider Electric A9D31610 is a 1P+N RCBO from the Acti 9 range, combining overcurrent and residual-current protection in a single module for single-phase circuits in residential and commercial distribution boards.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D31610\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iDPN N Vigi\u003c\/li\u003e\n\u003cli\u003eType: RCBO (residual-current circuit breaker with overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P + N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 10 A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 230...240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eResidual-current sensitivity (IΔn): 30 mA, Type AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230...240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065326792968,"sku":"SCHA9D31610","price":36.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d31610-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1pn-10a-c-curve-6000a-ac-type-30ma-365929.jpg?v=1735229809"},{"product_id":"a9d31616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1p-n-16a-c-curve-6000a-ac-type-30ma","title":"Schneider A9D31616 Acti9 iDPN N Vigi RCBO 1P+N 16A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric A9D31616 is an Acti 9 iDPN N Vigi RCBO (residual current circuit breaker with overcurrent protection), combining residual current and overcurrent protection in a single 1P+N module for single-phase 230–240 V AC installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D31616\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iDPN N Vigi\u003c\/li\u003e\n\u003cli\u003eType: RCBO (residual current circuit breaker with overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P + N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 16 A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IdN): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 230–240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230–240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065326891272,"sku":"SCHA9D31616","price":36.81,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d31616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1pn-16a-c-curve-6000a-ac-type-30ma-797662.jpg?v=1735229810"},{"product_id":"a9d56610-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1p-n-10a-b-curve-6000a-a-type-30ma","title":"Schneider A9D56610 Acti9 iDPN N Vigi RCBO 1P+N B 10A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric Acti9 iDPN N Vigi (A9D56610) is a 1P+N RCBO combining overcurrent and residual-current protection in a single device. Part of the Acti 9 range, it is designed for protection of final circuits in residential and commercial distribution boards.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D56610\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iDPN N Vigi\u003c\/li\u003e\n\u003cli\u003eType: RCBO (Residual Current Breaker with Overcurrent Protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P + N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 10 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: B\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 230–240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230–240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065327055112,"sku":"SCHA9D56610","price":41.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d56610-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1pn-10a-b-curve-6000a-a-type-30ma-497048.jpg?v=1735229949"},{"product_id":"a9d56616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1p-n-16a-b-curve-6000a-a-type-30ma","title":"Schneider A9D56616 Acti9 iDPN N Vigi RCBO 1P+N B 16A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric A9D56616 is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) from the Acti 9 range, designed to protect single-phase circuits against both overcurrent and earth-leakage faults.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D56616\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iDPN N Vigi\u003c\/li\u003e\n\u003cli\u003eType: RCBO (residual current circuit breaker with overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P + N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 16 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: B\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 230–240 V AC 50 Hz, per EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003cli\u003eResidual-current sensitivity (IΔn): 30 mA, Type A\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230–240 V AC 50 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065327153416,"sku":"SCHA9D56616","price":39.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d56616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1pn-16a-b-curve-6000a-a-type-30ma-127430.jpg?v=1735229948"},{"product_id":"a9d56620-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1p-n-20a-b-curve-6000a-a-type-30ma","title":"Schneider A9D56620 Acti9 iDPN N Vigi RCBO 1P+N 20A B 6000A 30mA Type A","description":"\u003cp\u003eThe Schneider Electric Acti9 iDPN N Vigi (A9D56620) is a 1P+N RCBO (residual current circuit breaker with overcurrent protection) from the Acti9 range, combining overload and short-circuit protection with residual current earth fault detection in a single compact device.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D56620\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: iDPN N Vigi\u003c\/li\u003e\n\u003cli\u003eType: RCBO (Residual Current Circuit Breaker with Overcurrent Protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current: 20A\u003c\/li\u003e\n\u003cli\u003eTripping curve: B\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6000A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity: 30mA\u003c\/li\u003e\n\u003cli\u003eRCD type: Type A\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065327218952,"sku":"SCHA9D56620","price":40.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d56620-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1pn-20a-b-curve-6000a-a-type-30ma-593628.jpg?v=1735229948"},{"product_id":"a9d56625-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1p-n-25a-b-curve-6000a-a-type-30ma","title":"Schneider A9D56625 Acti9 iDPN N Vigi RCBO 1P+N 25A B 6kA 30mA Type A","description":"\u003cp\u003eThe Schneider Electric Acti9 iDPN N Vigi (A9D56625) is a 1P+N RCBO (residual current circuit breaker with overcurrent protection) from the Acti9 range, combining miniature circuit breaker and residual current device protection in a single unit. It provides overcurrent protection via a B trip curve alongside earth-fault protection at 30mA Type A sensitivity, rated at 25A with a 6000A breaking capacity.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D56625\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: iDPN N Vigi\u003c\/li\u003e\n\u003cli\u003eType: RCBO (residual current circuit breaker with overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current: 25A\u003c\/li\u003e\n\u003cli\u003eTrip curve: B\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6000A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity: 30mA\u003c\/li\u003e\n\u003cli\u003eRCD type: Type A\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065327317256,"sku":"SCHA9D56625","price":48.69,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d56625-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1pn-25a-b-curve-6000a-a-type-30ma-796119.jpg?v=1735229949"},{"product_id":"a9dc3610-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40n-1p-n-10a-c-curve-6000a-a-type-30ma","title":"Schneider A9DC3610 Acti9 iCV40N RCBO 1P+N 10A C 6000A Type A 30mA","description":"\u003cp\u003eThe Schneider Electric A9DC3610 is a 1P+N residual current breaker with overcurrent protection (RCBO) from the Acti9 iCV40N range, combining overcurrent and earth fault protection in a single device.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9DC3610\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: iCV40N\u003c\/li\u003e\n\u003cli\u003eType: Residual current breaker with overcurrent protection (RCBO)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current: 10 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6000 A\u003c\/li\u003e\n\u003cli\u003eRCD type: A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity: 30 mA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065327546632,"sku":"SCHA9DC3610","price":33.76,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9dc3610-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40n-1pn-10a-c-curve-6000a-a-type-30ma-996412.jpg?v=1735229990"},{"product_id":"a9dc3616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40n-1p-n-16a-c-curve-6000a-a-type-30ma","title":"Schneider A9DC3616 Acti9 iCV40N RCBO 1P+N 16A C 6kA Type A 30mA","description":"\u003cp\u003eThe Schneider Electric A9DC3616 is an Acti9 iCV40N residual current breaker with overcurrent protection (RCBO), rated 1P+N 16A. It combines earth fault and overcurrent protection in a single device, providing protection against earth leakage, overloads, and short circuits.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9DC3616\u003c\/li\u003e\n\u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: iCV40N\u003c\/li\u003e\n\u003cli\u003eType: Residual current breaker with overcurrent protection (RCBO)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current: 16A\u003c\/li\u003e\n\u003cli\u003eTripping curve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6000A\u003c\/li\u003e\n\u003cli\u003eRCD type: A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity: 30mA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065327710472,"sku":"SCHA9DC3616","price":47.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9dc3616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40n-1pn-16a-c-curve-6000a-a-type-30ma-745699.jpg?v=1735229992"},{"product_id":"a9dc3620-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40n-1p-n-20a-c-curve-6000a-a-type-30ma","title":"Schneider A9DC3620 Acti9 iCV40N RCBO 1P+N 20A C 6kA 30mA Type A","description":"\u003cp\u003eThe Schneider Electric A9DC3620 is an Acti9 iCV40N residual current breaker with overcurrent protection (RCBO), providing combined overcurrent and residual current protection in a 1P+N configuration.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9DC3620\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: iCV40N\u003c\/li\u003e\n\u003cli\u003eType: RCBO (residual current breaker with overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current: 20A\u003c\/li\u003e\n\u003cli\u003eTripping curve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6000A\u003c\/li\u003e\n\u003cli\u003eRCD type: A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity: 30mA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065327808776,"sku":"SCHA9DC3620","price":52.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9dc3620-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40n-1pn-20a-c-curve-6000a-a-type-30ma-844700.jpg?v=1735229991"},{"product_id":"a9dc3625-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40n-1p-n-25a-c-curve-6000a-a-type-30ma","title":"Schneider A9DC3625 Acti9 iCV40N RCBO 1P+N 25A C 6kA 30mA Type A","description":"\u003cp\u003eThe Schneider Electric A9DC3625 is a residual current breaker with overcurrent protection (RCBO) from the Acti9 range, model iCV40N. It provides combined overcurrent and earth-fault protection in a 1P+N configuration.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9DC3625\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: iCV40N\u003c\/li\u003e\n\u003cli\u003eType: Residual current breaker with overcurrent protection (RCBO)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current: 25A\u003c\/li\u003e\n\u003cli\u003eCurve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6,000A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity: 30mA\u003c\/li\u003e\n\u003cli\u003eRCD type: Type A\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065327907080,"sku":"SCHA9DC3625","price":58.97,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9dc3625-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40n-1pn-25a-c-curve-6000a-a-type-30ma-897655.jpg?v=1735229989"},{"product_id":"a9df3616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40n-1p-n-16a-c-curve-6000a-a-si-type-30ma","title":"Schneider A9DF3616 Acti9 iCV40N RCBO 1P+N 16A C 6000A A-SI 30mA","description":"\u003cp\u003eThe Schneider Electric A9DF3616 is a residual current breaker with overcurrent protection (RCBO) from the Acti9 range, model iCV40N, combining overcurrent and earth fault protection in a single 1P+N device.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9DF3616\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: iCV40N\u003c\/li\u003e\n\u003cli\u003eType: Residual current breaker with overcurrent protection (RCBO)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current: 16A\u003c\/li\u003e\n\u003cli\u003eCurve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6000A\u003c\/li\u003e\n\u003cli\u003eRCD type: A-SI\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity: 30mA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065328005384,"sku":"SCHA9DF3616","price":34.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9df3616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40n-1pn-16a-c-curve-6000a-a-si-type-30ma-8580694.jpg?v=1757426812"},{"product_id":"a9e18073-linear-switch-issw-1-c-o-20a-250-v-ac-3-positions","title":"Schneider A9E18073 Acti9 iSSW Changeover Switch 1P 20A 250V AC","description":"\u003cp\u003eThe Schneider Electric A9E18073 is an iSSW selector switch from the Acti9 range, designed for changeover switching applications. It provides a single-pole changeover contact with three selector positions, rated for use at 20 A and 250 V AC 50\/60 Hz.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9E18073\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: iSSW\u003c\/li\u003e\n\u003cli\u003eType: Changeover switch (selector switch)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P\u003c\/li\u003e\n\u003cli\u003eContact configuration: 1 C\/O\u003c\/li\u003e\n\u003cli\u003ePositions: 3\u003c\/li\u003e\n\u003cli\u003eRated current (Ie): 20 A\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 250 V AC 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065328070920,"sku":"SCHA9E18073","price":7.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9e18073-schneider-electric-linear-switch-issw-1-co-20a-250-v-ac-3-positions-5730213.jpg?v=1757426811"},{"product_id":"a9l20600-iprd20-modular-surge-arrester-3p-n-350v","title":"Schneider A9L20600 Acti9 iPRD20 SPD 3P+N 350V","description":"\u003cp\u003eThe Schneider Electric A9L20600 is an Acti 9 iPRD20 withdrawable modular surge protection device (SPD) in a 3P+N configuration, designed for overvoltage protection in three-phase plus neutral AC installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9L20600\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eProduct name: Acti 9 iPRD\u003c\/li\u003e\n\u003cli\u003eModel: iPRD20\u003c\/li\u003e\n\u003cli\u003eType: Withdrawable surge protection device (SPD)\u003c\/li\u003e\n\u003cli\u003ePoles: 3P + N\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230\/400 V AC (±10%) at 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065330397448,"sku":"SCHA9L20600","price":76.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9l20600-iprd20-modular-surge-arrester-3p-n-350v-177090.jpg?v=1735231017"},{"product_id":"a9l40400-iprd40-modular-surge-arrester-4p-350v","title":"Schneider A9L40400 Acti9 iPRD40 SPD 4P 350V","description":"\u003cp\u003eThe Schneider Electric A9L40400 is a 4-pole withdrawable modular surge protection device (SPD) from the Acti9 iPRD range, designed to protect low-voltage electrical installations against transient overvoltages on 230\/400 V AC networks.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9L40400\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: iPRD40\u003c\/li\u003e\n\u003cli\u003eType: Withdrawable surge protection device (SPD)\u003c\/li\u003e\n\u003cli\u003ePoles: 4P\u003c\/li\u003e\n\u003cli\u003eMaximum continuous operating voltage (Uc): 350 V\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230\/400 V AC (±10%) at 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065330528520,"sku":"SCHA9L40400","price":66.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9l40400-iprd40-modular-surge-arrester-4p-350v-395076.jpg?v=1735231017"},{"product_id":"a9l40600-iprd40-modular-surge-arrester-3p-n-350v","title":"Schneider A9L40600 Acti9 iPRD40 SPD 3P+N 350V","description":"\u003cp\u003eThe Schneider Electric A9L40600 is an iPRD40 withdrawable surge protection device (SPD) from the Acti 9 range, designed to protect three-phase electrical installations against transient overvoltages.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9L40600\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eProduct name: Acti 9 iPRD\u003c\/li\u003e\n\u003cli\u003eModel: iPRD40\u003c\/li\u003e\n\u003cli\u003eType: Withdrawable surge protection device (SPD)\u003c\/li\u003e\n\u003cli\u003ePoles: 3P + N\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230\/400 V AC (±10%) at 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065330626824,"sku":"SCHA9L40600","price":70.88,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9l40600-iprd40-modular-surge-arrester-3p-n-350v-874978.jpg?v=1735231016"},{"product_id":"a9n18364-miniature-circuit-breaker-mcb-acti9-c120n-3p-63a-c-curve-10000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9N18364 Acti9 C120N MCB 3P C 63A 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18364 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 C120 range, intended for overcurrent protection in industrial and commercial distribution boards.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9N18364\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: C120N\u003c\/li\u003e\n\u003cli\u003eType: Miniature circuit breaker (MCB)\u003c\/li\u003e\n\u003cli\u003ePoles: 3P\u003c\/li\u003e\n\u003cli\u003eRated current (In): 63 A at 30 °C\u003c\/li\u003e\n\u003cli\u003eTripping curve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10,000 A at 230–400 V AC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): ≤ 375 V DC\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065331380488,"sku":"SCHA9N18364","price":62.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18364-miniature-circuit-breaker-mcb-acti9-c120n-3p-63a-c-curve-10000a-iecen-60898-1-10ka-iecen-60947-2-706526.jpg?v=1735231069"},{"product_id":"a9n18365-miniature-circuit-breaker-mcb-acti9-c120n-3p-80a-c-curve-10000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9N18365 Acti9 C120N MCB 3P C 80A 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18365 is a C120N miniature circuit breaker (MCB) from the Acti 9 range, providing overcurrent and short-circuit protection with a C tripping curve.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9N18365\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: C120N\u003c\/li\u003e\n\u003cli\u003eType: Miniature circuit breaker (MCB)\u003c\/li\u003e\n\u003cli\u003ePoles: 3P\u003c\/li\u003e\n\u003cli\u003eRated current In: 80 A at 30 °C\u003c\/li\u003e\n\u003cli\u003eTripping curve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity Icn: 10,000 A at 230–400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n\u003cli\u003eRated voltage Ue: ≤ 375 V DC\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065331413256,"sku":"SCHA9N18365","price":96.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18365-miniature-circuit-breaker-mcb-acti9-c120n-3p-80a-c-curve-10000a-iecen-60898-1-10ka-iecen-60947-2-886409.jpg?v=1735231075"},{"product_id":"a9n18367-miniature-circuit-breaker-mcb-acti9-c120n-3p-100a-c-curve-10000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9N18367 Acti9 C120N MCB 3P C 100A 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18367 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 C120 range, providing overcurrent protection in AC and DC distribution systems.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9N18367\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: C120N\u003c\/li\u003e\n\u003cli\u003eType: Miniature circuit breaker (MCB)\u003c\/li\u003e\n\u003cli\u003ePoles: 3P\u003c\/li\u003e\n\u003cli\u003eRated current (In): 100 A at 30 °C\u003c\/li\u003e\n\u003cli\u003eTripping curve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10000 A at 230...400 V AC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): ≤375 V DC\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065331478792,"sku":"SCHA9N18367","price":99.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18367-miniature-circuit-breaker-mcb-acti9-c120n-3p-100a-c-curve-10000a-iecen-60898-1-10ka-iecen-60947-2-466654.jpg?v=1735231075"},{"product_id":"a9n18369-miniature-circuit-breaker-mcb-acti9-c120n-3p-125a-c-curve-10000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9N18369 Acti9 C120N MCB 3P C 125A 10kA","description":"\u003cp\u003eThe Schneider Electric Acti9 C120N (A9N18369) is a 3-pole miniature circuit breaker from the Acti9 range, designed for overcurrent protection in commercial and industrial low-voltage distribution boards.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9N18369\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: C120N\u003c\/li\u003e\n\u003cli\u003eType: Miniature circuit breaker (MCB)\u003c\/li\u003e\n\u003cli\u003ePoles: 3P\u003c\/li\u003e\n\u003cli\u003eRated current (In): 125 A at 30 °C\u003c\/li\u003e\n\u003cli\u003eTripping curve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10 kA at 230–400 V AC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): ≤ 375 V DC\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065332494600,"sku":"SCHA9N18369","price":155.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18369-miniature-circuit-breaker-mcb-acti9-c120n-3p-125a-c-curve-10000a-iecen-60898-1-10ka-iecen-60947-2-676520.jpg?v=1735231075"},{"product_id":"a9n26476-mx-shunt-trip-415vac-110-130vdc","title":"Schneider A9N26476 Acti9 MX Shunt Trip Release 415VAC 110-130VDC","description":"\u003cp\u003eThe Schneider Electric A9N26476 is an MX shunt trip release in the Acti9 range, rated at 415VAC and 110-130VDC for electrically tripping compatible Acti9 devices.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9N26476\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: MX\u003c\/li\u003e\n\u003cli\u003eType: Shunt trip release\u003c\/li\u003e\n\u003cli\u003eRated voltage AC: 415 VAC\u003c\/li\u003e\n\u003cli\u003eRated voltage DC: 110-130 VDC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065332592904,"sku":"SCHA9N26476","price":30.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n26476-mx-shunt-trip-415vac-110-130vdc-118126.jpg?v=1735231202"},{"product_id":"a9r21225-residual-current-circuit-breaker-rccb-acti9-iid-2p-25a-a-type-30ma","title":"Schneider A9R21225 Acti9 iID RCCB 2P 25A 30mA Type A","description":"\u003cp\u003eThe Schneider Electric A9R21225 is a 2-pole residual current circuit breaker (RCCB) from the Acti 9 range, providing earth-fault protection in residential and commercial installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9R21225\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iID\u003c\/li\u003e\n\u003cli\u003eType: RCCB (residual current circuit breaker)\u003c\/li\u003e\n\u003cli\u003ePoles: 2P\u003c\/li\u003e\n\u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: Type A\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 220...240 V AC 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333018888,"sku":"SCHA9R21225","price":32.68,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r21225-residual-current-circuit-breaker-rccb-acti9-iid-2p-25a-a-type-30ma-517757.jpg?v=1735231322"},{"product_id":"a9r21440-residual-current-circuit-breaker-rccb-acti9-iid-4p-40a-a-type-30ma","title":"Schneider A9R21440 Acti9 iID RCCB 4P 40A 30mA Type A","description":"\u003cp\u003eThe Schneider Electric A9R21440 is a 4-pole residual current circuit breaker (RCCB) from the Acti 9 range, providing personal protection against earth leakage faults in three-phase AC installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9R21440\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iID\u003c\/li\u003e\n\u003cli\u003eType: RCCB (Residual Current Circuit Breaker)\u003c\/li\u003e\n\u003cli\u003ePoles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: Type A\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 380...415 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333149960,"sku":"SCHA9R21440","price":53.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r21440-residual-current-circuit-breaker-rccb-acti9-iid-4p-40a-a-type-30ma-169712.jpg?v=1735231322"},{"product_id":"a9r41225-residual-current-circuit-breaker-rccb-acti9-iid-2p-25a-ac-type-30ma","title":"Schneider A9R41225 Acti9 iID RCCB 2P 25A 30mA AC","description":"\u003cp\u003eThe Schneider Electric A9R41225 is an Acti 9 iID residual current circuit breaker (RCCB), providing 30 mA earth leakage protection in a 2-pole configuration for circuits rated 220–240 V AC 50\/60 Hz.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9R41225\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iID\u003c\/li\u003e\n\u003cli\u003eType: Residual current circuit breaker (RCCB)\u003c\/li\u003e\n\u003cli\u003ePoles: 2P\u003c\/li\u003e\n\u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 220...240 V AC 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333248264,"sku":"SCHA9R41225","price":29.77,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r41225-residual-current-circuit-breaker-rccb-acti9-iid-2p-25a-ac-type-30ma-469002.jpg?v=1735231385"},{"product_id":"a9r41240-residual-current-circuit-breaker-rccb-acti9-iid-2p-40a-ac-type-30ma","title":"Schneider A9R41240 Acti9 iID RCCB 2P 40A 30mA AC Type","description":"\u003cp\u003eThe Schneider Electric Acti9 iID (reference A9R41240) is a 2-pole residual current circuit breaker (RCCB) from the Acti9 range, providing earth-leakage protection in residential and commercial low-voltage installations. It offers no overcurrent protection and must be used in conjunction with a suitable overcurrent protective device.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9R41240\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: iID\u003c\/li\u003e\n\u003cli\u003eType: RCCB (residual current circuit breaker, no overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 2P\u003c\/li\u003e\n\u003cli\u003eRated current In: 40 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity IΔn: 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage Ue: 220...240 V AC 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333313800,"sku":"SCHA9R41240","price":30.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r41240-residual-current-circuit-breaker-rccb-acti9-iid-2p-40a-ac-type-30ma-375306.jpg?v=1735231385"},{"product_id":"a9r41425-residual-current-circuit-breaker-rccb-acti9-iid-4p-25a-ac-type-30ma","title":"Schneider A9R41425 Acti9 iID RCCB 4P 25A 30mA AC","description":"\u003cp\u003eThe A9R41425 is a 4-pole RCCB from the Schneider Electric Acti 9 iID range, providing residual-current earth-fault protection for three-phase and neutral AC installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9R41425\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iID\u003c\/li\u003e\n\u003cli\u003eType: RCCB (Residual Current Circuit Breaker)\u003c\/li\u003e\n\u003cli\u003ePoles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 380...415 V AC 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333379336,"sku":"SCHA9R41425","price":41.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r41425-residual-current-circuit-breaker-rccb-acti9-iid-4p-25a-ac-type-30ma-348688.jpg?v=1735231384"},{"product_id":"a9r41440-residual-current-circuit-breaker-rccb-acti9-iid-4p-40a-ac-type-30ma","title":"Schneider A9R41440 Acti9 iID RCCB 4P 40A 30mA AC","description":"\u003cp\u003eThe Schneider Electric A9R41440 is an Acti 9 iID 4-pole residual current circuit breaker (RCCB) providing earth-fault and personnel protection in three-phase installations. It offers residual-current tripping without integrated overcurrent protection.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9R41440\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iID\u003c\/li\u003e\n\u003cli\u003eType: RCCB (residual current circuit breaker)\u003c\/li\u003e\n\u003cli\u003ePoles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 380...415 V AC 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333412104,"sku":"SCHA9R41440","price":40.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r41440-residual-current-circuit-breaker-rccb-acti9-iid-4p-40a-ac-type-30ma-862931.jpg?v=1735231384"},{"product_id":"a9s60120-acti9-isw-switch-1-pole-20-a-250v","title":"Schneider A9S60120 Acti9 iSW Switch-Disconnector 1P 20A 250V","description":"\u003cp\u003eThe Schneider Electric A9S60120 is a 1-pole iSW switch-disconnector from the Acti 9 range, designed for the safe isolation of electrical circuits at 250 V AC.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9S60120\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iSW\u003c\/li\u003e\n\u003cli\u003eType: Switch-disconnector\u003c\/li\u003e\n\u003cli\u003ePoles: 1P\u003c\/li\u003e\n\u003cli\u003eRated current (Ie): 20 A\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 250 V AC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eUtilisation category: AC-22A\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333543176,"sku":"SCHA9S60120","price":3.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9s60120-acti9-isw-switch-1-pole-20-a-250v-193178.jpg?v=1735231384"}],"url":"https:\/\/gabbyelectric.com\/en-ca\/collections\/circuit-protection.oembed?page=82","provider":"Gabby Electric","version":"1.0","type":"link"}