Schneider Electric A9N18357 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 C120N range, rated at 80 A with a C tripping characteristic. It provides thermomagnetic protection for AC distribution systems with a breaking capacity of 10 kA at 230-400 V AC, making it suitable for high-demand electrical distribution applications.
Technical specifications:
- Commercial reference: A9N18357
- Manufacturer: Schneider Electric
- Series / range: Acti 9 C120
- Product type: Miniature Circuit Breaker (MCB)
- Number of poles: 1P
- Number of protected poles: 1
- Rated current [In]: 80 A at 30°C
- Tripping curve: C
- Network type: AC
- Protection unit technology: Thermomagnetic
- Rated voltage [Ue]: 220-240 V AC / 380-415 V AC 50/60 Hz; 125 V DC / up to 144 V DC
- Breaking capacity [Icu]: 10 kA at 220-240 V AC; 3 kA at 380-415 V AC (IT network); 10 kA Icn at 230-400 V AC per EN/IEC 60898-1
- Rated insulation voltage [Ui]: 500 V AC 50/60 Hz
- Rated impulse withstand voltage [Uimp]: 6 kV
- Overcurrent protection range: 5-10 x In
- Mounting: 35 mm symmetrical DIN rail, clip-on
- Connection type: Tunnel terminals, 1-50 mm² solid / 1.5-35 mm² flexible
- Tightening torque: 3.5 N.m
- Strip length: 15 mm
- Dimensions (WxHxD): 27 x 81 x 73 mm
- Weight: 0.205 kg
- IP rating: IP20 per IEC 60529
- Operating temperature: -25 to 70°C
- Storage temperature: -40 to 85°C
- Operating altitude: up to 2000 m
- Standards: EN/IEC 60898-1, EN/IEC 60947-2
- Certification: EAC
- Warranty: 18 months
Features and benefits:
- Thermomagnetic protection for reliable overload and short-circuit tripping
- C curve characteristic suitable for loads with moderate inrush currents
- Compatible with comb busbar distribution blocks for efficient panel wiring
- Handle sealable with 0.7 mm cable diameter in ON or OFF position for tamper protection
- Suitable for isolation per IEC 60947-2, enabling safe maintenance procedures
- Mechanical endurance of 20,000 cycles; electrical endurance of 5,000 cycles
Applications:
- Final distribution boards in commercial and industrial electrical installations
- Protection of distribution circuits in industrial control panels
- AC and DC distribution systems requiring high breaking capacity
- Installations requiring circuit isolation capability per IEC 60947-2
Compliant with EN/IEC 60898-1 and EN/IEC 60947-2. Part of the Schneider Electric Acti 9 C120 range.
Also known as: Schneider A9N18357, Schneider Electric A9N18357, Acti9 C120N 1P 80A MCB, Schneider 80A miniature circuit breaker.
When sold out, you can still preorder by requesting a quote below.
Important
The images shown are for illustration purposes only and may not be an exact
representation of the product.