Schneider A9F94102 Miniature Circuit Breaker (MCB), Acti9 iC60L, 1P C2A 15kA
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric A9F94102 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60L range, rated at 2 A with a C tripping curve. It provides thermomagnetic overcurrent protection with a high breaking capacity of 15 kA at 230 V AC, suitable for both AC and DC networks.
Technical specifications:
- Commercial reference: A9F94102
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 iC60
- Short device name: iC60L
- Number of poles: 1P
- Number of protected poles: 1
- Rated current: 2 A
- Tripping curve: C
- Network type: AC / DC
- Protection unit technology: Thermomagnetic
- Breaking capacity (Icn): 15 kA at 230 V AC 50/60 Hz per EN/IEC 60898-1
- Breaking capacity (Icu): 100 kA at 220-240 V AC 50/60 Hz per EN/IEC 60947-2
- Breaking capacity (Icu): 25 kA at 12-48 V DC per EN/IEC 60947-2
- Service breaking capacity (Ics): 100 kA at 220-240 V AC per EN/IEC 60947-2
- Limitation class: 3 per EN/IEC 60898-1
- Rated insulation voltage (Ui): 500 V AC 50/60 Hz
- Rated impulse withstand voltage (Uimp): 6 kV
- Overcurrent limiting: 8 x In +/- 20%
- Mounting: DIN rail
- Width: 18 mm (2 rows of 9 mm)
- Height: 85 mm
- Depth: 78.5 mm
- Weight: 0.215 kg
- IP rating: IP20 per IEC/EN 60529
- Operating temperature: -35 to 70 °C
- Storage temperature: -40 to 85 °C
- Relative humidity: 95% at 55 °C
- Overvoltage category: IV
- Connection: Single terminal block (top or bottom), 1-25 mm² rigid / 1-16 mm² flexible
- Strip length: 14 mm
- Tightening torque: 2 N.m
- Mechanical endurance: 20,000 cycles
- Electrical endurance: 10,000 cycles
- Warranty: 18 months
Features and benefits:
- High breaking capacity of 100 kA Icu at 220-240 V AC for use in demanding industrial installations
- Suitable for both AC and DC networks, offering installation flexibility
- Limitation class 3 reduces the let-through energy during fault conditions, protecting downstream equipment
- Compatible with comb busbar distribution blocks from top or bottom, simplifying panel wiring
- Contact position indicator and trip indicator provide clear local status signalling
- Suitable for isolation per EN/IEC 60898-1 and EN/IEC 60947-2
Applications:
- Final distribution boards in residential and commercial buildings
- Protection of low-current circuits such as control wiring and sensitive instrumentation
- Industrial control panels and automation enclosures requiring high breaking capacity
- DC circuit protection in renewable energy or battery-backed systems
- Switchboards where space-saving 18 mm modular devices are required
Compliant with EN/IEC 60898-1 and EN/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.
Also known as: Schneider A9F94102, Schneider Electric A9F94102, iC60L 1P C2A MCB, Acti9 miniature circuit breaker 2A.
When sold out, you can still preorder by requesting a quote below.
Important
The images shown are for illustration purposes only and may not be an exact
representation of the product.