Schneider A9F74163 Acti9 iC60N MCB 1P 63 A C Curve 10kA
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric A9F74163 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 63 A with a C tripping curve for thermomagnetic overload and short-circuit protection. Compatible with both AC and DC networks, it delivers a breaking capacity of 10 kA at 220-240 V AC per IEC 60947-2.
Technical specifications:
- Commercial reference: A9F74163
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 iC60
- Product type: Miniature circuit breaker (MCB)
- Number of poles: 1P
- Rated current: 63 A
- Tripping curve: C
- Network type: AC / DC
- Protection technology: Thermomagnetic
- Breaking capacity (Icn): 6000 A at 230 V AC 50/60 Hz (IEC/EN 60898-1)
- Breaking capacity (Icu): 10 kA at 220-240 V AC; 36 kA at 12-60 V AC; 15 kA at 12-60 V DC; 10 kA at 72 V DC (IEC/EN 60947-2)
- Service breaking capacity (Ics): 7.5 kA at 220-240 V AC; 27 kA at 12-60 V AC (IEC/EN 60947-2)
- Limitation class: 3
- Rated insulation voltage: 500 V AC 50/60 Hz (IEC/EN 60947-2)
- Rated impulse withstand voltage: 6 kV (IEC/EN 60947-2)
- Overcurrent protection limit: 8 x In +/- 20%
- Use category: A (IEC/EN 60947-2)
- Mounting: DIN rail, fixed
- Dimensions (WxHxD): 18 x 85 x 78.5 mm
- Weight: 0.215 kg
- IP protection: IP20 (IEC/EN 60529)
- Pollution degree: 3 (IEC/EN 60947-2)
- Overvoltage category: IV
- Operating temperature: -35 to 70°C
- Storage temperature: -40 to 85°C
- Connection: 1-35 mm² rigid / 1-25 mm² flexible; strip length 14 mm; tightening torque 3.5 N.m
- Mechanical endurance: 20,000 cycles
- Electrical endurance: 10,000 cycles
- Standards: IEC/EN 60898-1, IEC/EN 60947-2
Features and benefits:
- Thermomagnetic protection technology responds reliably to both sustained overloads and short-circuit faults
- Rated for use as an isolating device per IEC/EN 60898-1 and IEC/EN 60947-2
- Comb busbar compatible (upper or lower connection) for straightforward distribution board assembly
- Limitation class 3 reduces let-through energy, protecting downstream components and wiring
- Contact position indicator and trip indicator provide clear local circuit status monitoring
- Suitable for DC networks including up to 72 V DC, broadening installation flexibility
Applications:
- Final distribution boards in residential and commercial buildings
- Industrial switchboards and control panels
- DC power distribution in renewable energy and battery storage systems
- Installations requiring overvoltage category IV and pollution degree 3 compliance
- Circuits where class 3 energy limitation is needed to safeguard sensitive downstream equipment
Compliant with IEC/EN 60898-1 and IEC/EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.