{"title":"1 Pole MCB","description":"\u003cp\u003eProtect your circuits with our \u003cstrong data-start=\"253\" data-end=\"267\"\u003e1 pole MCB\u003c\/strong\u003e range, engineered for precision and safety in single-phase applications. These compact miniature circuit breakers guard against overloads and short circuits, making them ideal for residential, commercial, and light industrial use. Built by top-tier brands, each 1 pole breaker combines durability, easy installation, and international safety compliance - ensuring reliable performance for your electrical system.\u003c\/p\u003e","products":[{"product_id":"a9n18369-miniature-circuit-breaker-mcb-acti9-c120n-3p-125a-c-curve-10000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9N18369 Acti9 C120N MCB 1P 6 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18369 is a 3-pole 125 A Miniature Circuit Breaker (MCB) from the Acti 9 C120N range, designed for electrical power distribution. Featuring a C tripping curve and thermomagnetic protection unit, it delivers a rated breaking capacity of 10 kA Icn at 230...400 V AC per EN\/IEC 60898-1 and up to 20 kA Icu at 220...240 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9N18369\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 C120\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current: 125 A at 30°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eRated voltage: 220...440 V AC 50\/60 Hz; up to 375 V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 10 kA at 230...400 V AC - EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220...240 V AC; 10 kA at 380...415 V AC; 6 kA at 440 V AC - EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm symmetrical DIN rail, clip-on\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals, 1...50 mm² solid \/ 1.5...35 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 81 x 81 x 73 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.615 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-2, EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertification: EAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC tripping curve with 5...10 x In range, suitable for loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting for fast, tool-free installation in distribution boards\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks for efficient multi-pole busbar connection\u003c\/li\u003e\n  \u003cli\u003eLockable handle in ON or OFF position for tamper-proof lockout\/tagout\u003c\/li\u003e\n  \u003cli\u003eON\/OFF contact position indicator for clear local status reading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards and sub-distribution panels in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of cables and equipment in industrial automation and control panels\u003c\/li\u003e\n  \u003cli\u003ePower distribution switchgear assemblies requiring IEC 60947-2 compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2 and EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9N18369, Schneider Electric A9N18369, C120N 3P 125A MCB, Acti9 C120N 125A circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065332494600,"sku":"SCHA9N18369","price":155.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18369-miniature-circuit-breaker-mcb-acti9-c120n-3p-125a-c-curve-10000a-iecen-60898-1-10ka-iecen-60947-2-676520.jpg?v=1735231075"},{"product_id":"a9f73106-miniature-circuit-breaker-mcb-acti9-ic60n-1p-6a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73106 Acti9 iC60N MCB 1P 6 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73106 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 6 A with a B tripping curve. Designed for AC and DC networks, it delivers a rated breaking capacity (Icn) of 6000 A at 230 V AC and an ultimate breaking capacity (Icu) of 10 kA at 220-240 V AC, providing reliable overcurrent protection in power distribution applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73106\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB), iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 6 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 230 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eUltimate breaking capacity (Icu): 10 kA at 220-240 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1-25 mm² rigid \/ 1-16 mm² flexible; strip length 14 mm; tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85 °C\u003c\/li\u003e\n  \u003cli\u003eStandards: EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eTrip indicator for immediate local fault signalling\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower connection\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70 °C for demanding environments\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category IV and pollution degree 3, rated for origin-of-installation use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and socket outlet circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring compact 18 mm wide single-pole protection\u003c\/li\u003e\n  \u003cli\u003eLow-voltage DC distribution systems up to 72 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73106, Schneider Electric A9F73106, iC60N 6A B curve MCB, Acti9 1P miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065504821512,"sku":"SCHA9F73106","price":4.46,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73106-miniature-circuit-breaker-mcb-acti9-ic60n-1p-6a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-140940.jpg?v=1735230349"},{"product_id":"a9f73110-miniature-circuit-breaker-mcb-acti9-ic60n-1p-10a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73110 Acti9 iC60N MCB 1P 10 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73110 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 10 A with a B tripping curve. Designed for electrical energy distribution, it provides thermomagnetic protection on both AC and DC networks, with a breaking capacity of 6,000 A Icn at 230 V AC per EN\/IEC 60898-1 and 10 kA Icu at 220-240 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73110\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current: 10 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 230 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 220-240 V AC 50\/60 Hz \/ 10 kA at 72 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB tripping curve suited to resistive and lighting loads with low inrush currents\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks for flexible application\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block compatible on upper or lower connection\u003c\/li\u003e\n  \u003cli\u003eTrip indicator provides quick local fault signaling\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eHigh mechanical endurance of 20,000 cycles and electrical endurance of 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and resistive load circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and electrical enclosures\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems including low-voltage DC installations\u003c\/li\u003e\n  \u003cli\u003eElectrical installations requiring isolation capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73110, Schneider Electric A9F73110, iC60N 10A B curve MCB, Acti9 1P 10A miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065504919816,"sku":"SCHA9F73110","price":3.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73110-miniature-circuit-breaker-mcb-acti9-ic60n-1p-10a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-457921.jpg?v=1735230353"},{"product_id":"a9f73116-miniature-circuit-breaker-mcb-acti9-ic60n-1p-16a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73116 Acti9 iC60N MCB 1P 16 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73116 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 16 A with a B tripping curve and thermomagnetic protection technology. It delivers overcurrent and short-circuit protection on both AC and DC networks, with a breaking capacity of 6000 A Icn at 230 V AC per EN\/IEC 60898-1 and 10 kA Icu at 220-240 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73116\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current: 16 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 230 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 220-240 V AC 50\/60 Hz; 36 kA at 12-60 V AC; 10 kA at 72 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm | Height: 85 mm | Depth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-25 mm² rigid \/ 1-16 mm² flexible conductors (upper or lower)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB tripping curve provides sensitive overcurrent protection suited to circuits with low inrush currents\u003c\/li\u003e\n  \u003cli\u003eRated for both AC and DC networks, enabling use in photovoltaic and battery-backed systems\u003c\/li\u003e\n  \u003cli\u003eCertified as a disconnecting device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBuilt-in trip indicator allows quick local fault identification without additional instrumentation\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm (2 x 9 mm module) width maximises usable panel space\u003c\/li\u003e\n  \u003cli\u003eTropicalization class 2 per IEC 60068-1 for reliable operation in high-humidity environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and light commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and socket outlet circuits with low inrush loads\u003c\/li\u003e\n  \u003cli\u003eDC distribution in photovoltaic installations and battery storage systems\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and switchgear assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73116, Schneider Electric A9F73116, iC60N 16A B curve MCB, Acti 9 miniature circuit breaker 16A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065504952584,"sku":"SCHA9F73116","price":3.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73116-miniature-circuit-breaker-mcb-acti9-ic60n-1p-16a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-548116.jpg?v=1735230350"},{"product_id":"a9f73120-miniature-circuit-breaker-mcb-acti9-ic60n-1p-20a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73120 Acti9 iC60N MCB 1P 20 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73120 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 20 A with a B tripping curve. Designed for electrical distribution, it offers a breaking capacity of 6000 A at 230 V AC and 10 kA at 240 V AC, with compatibility for both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73120\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current: 20 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 230 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 240 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 72 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 15 kA at 12-60 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for both AC and DC network applications, providing versatile deployment options\u003c\/li\u003e\n  \u003cli\u003eB tripping curve provides sensitive overcurrent protection suited to resistive and light inductive loads\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimizes let-through energy, enhancing downstream equipment protection\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator enable quick local status verification\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible (top or bottom) for streamlined distribution board assembly\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm width maximizes panel space efficiency on DIN rail installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial electrical installations\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and resistive loads requiring sensitive B curve tripping\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery-backed systems up to 72 V DC\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and low-voltage electrical distribution enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73120, Schneider Electric A9F73120, Acti9 iC60N 20A MCB, Schneider 1P 20A B curve circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065505018120,"sku":"SCHA9F73120","price":3.11,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73120-miniature-circuit-breaker-mcb-acti9-ic60n-1p-20a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-270674.jpg?v=1735230356"},{"product_id":"a9f73125-miniature-circuit-breaker-mcb-acti9-ic60n-1p-25a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73125 Acti9 iC60N MCB 1P 25 A B Curve 10kA","description":"\u003cp\u003eSchneider Electric A9F73125 is a 1-pole, 25 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, designed for electrical power distribution. It features a B tripping curve with a breaking capacity of 10 kA at 220-240 V AC and is suitable for both AC and DC network types.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73125\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 25 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 230 V AC 50\/60 Hz per EN\/IEC 60898-1; 10 kA Icu at 220-240 V AC per EN\/IEC 60947-2; 15 kA Icu at 12-60 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 7.5 kA (75%) at 220-240 V AC; 6000 A (100%) at 230 V AC per EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eUtilization category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStripping length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for both AC and DC networks, offering flexibility across different installation types\u003c\/li\u003e\n  \u003cli\u003eB tripping curve provides sensitive overcurrent protection, ideal for loads with low inrush currents\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces energy let-through during fault conditions\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator provide clear local status signalling\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks (top or bottom), simplifying panel wiring\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation duty per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and low-inrush electrical loads\u003c\/li\u003e\n  \u003cli\u003eDC power distribution systems at voltages up to 72 V\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring compact 18 mm DIN rail mounted protection\u003c\/li\u003e\n  \u003cli\u003eElectrical power distribution switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73125, Schneider Electric A9F73125, iC60N 1P 25A B curve MCB, Acti9 miniature circuit breaker 25A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065505083656,"sku":"SCHA9F73125","price":3.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73125-miniature-circuit-breaker-mcb-acti9-ic60n-1p-25a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-530789.jpg?v=1735230350"},{"product_id":"a9f73132-miniature-circuit-breaker-mcb-acti9-ic60n-1p-32a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73132 Acti9 iC60N MCB 1P 32 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73132 is a 1-pole, 32 A Miniature Circuit Breaker from the Acti 9 iC60N series, designed for electrical energy distribution. It combines a B tripping curve with thermomagnetic protection, delivering 6,000 A Icn at 230 V AC per IEC 60898-1 and 10 kA Icu at 220-240 V AC per IEC 60947-2. Rated for both AC and DC networks, it provides reliable overcurrent and short-circuit protection.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73132\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current: 32 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70 °C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1...35 mm² rigid \/ 1...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60898-1, IEC 60947-2, EN 60898-1, EN 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection with B tripping curve for reliable overcurrent and short-circuit disconnection\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection threshold at 4 x In +\/-20% per the product specifications\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks, offering broad installation flexibility\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting with comb busbar distribution block compatibility, upper or lower connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and light commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of circuits in low-voltage electrical installations\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in low-voltage DC distribution systems\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and low-voltage distribution switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, IEC 60947-2, EN 60898-1, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73132, Schneider Electric A9F73132, iC60N 1P 32A B curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065505509640,"sku":"SCHA9F73132","price":4.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73132-miniature-circuit-breaker-mcb-acti9-ic60n-1p-32a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-823003.jpg?v=1735230349"},{"product_id":"a9f73140-miniature-circuit-breaker-mcb-acti9-ic60n-1p-40a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73140 Acti9 iC60N MCB 1P 40 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73140 is a single-pole miniature circuit breaker from the Acti9 iC60N range, rated 40 A with B tripping curve. It provides overload and short-circuit protection for final circuits in distribution boards, rated 6000A under IEC\/EN 60898-1 and 10kA under IEC\/EN 60947-2. Mounts on 35mm DIN rail in 18mm module widths per pole.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePart number: A9F73140\u003c\/li\u003e\n\u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli\u003eSeries: Acti9 iC60N\u003c\/li\u003e\n\u003cli\u003ePoles: 1P\u003c\/li\u003e\n\u003cli\u003eRated current: 40 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: B\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (IEC 60898-1): 6000A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (IEC 60947-2): 10kA\u003c\/li\u003e\n\u003cli\u003eRated voltage: 230V AC (line to neutral)\u003c\/li\u003e\n\u003cli\u003eMounting: 35mm DIN rail, 18mm\/pole\u003c\/li\u003e\n\u003cli\u003eStandards: IEC\/EN 60898-1, IEC\/EN 60947-2, CE\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eB curve - suited to general wiring protection where low-inrush loads such as resistive heating, lighting, and cable protection are involved\u003c\/li\u003e\n\u003cli\u003eActi9 system - compatible with Vigi RCD blocks, auxiliary contacts, shunt trips, and Acti9 comb busbars\u003c\/li\u003e\n\u003cli\u003e18mm\/pole width - standard Acti9 pitch, slots into any Multi 9 distribution board row\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection in domestic, commercial, and industrial distribution boards\u003c\/li\u003e\n\u003cli\u003eSub-distribution panels and MCB boards using 18mm DIN rail modules\u003c\/li\u003e\n\u003cli\u003eActi9 assemblies with Vigi RCD blocks for combined MCB+RCD protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Schneider A9F73140, Acti9 iC60N 1P 40 A B curve MCB, A9F73140 miniature circuit breaker 40 A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065505575176,"sku":"SCHA9F73140","price":5.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73140-miniature-circuit-breaker-mcb-acti9-ic60n-1p-40a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-100297.jpg?v=1735230357"},{"product_id":"a9f73163-miniature-circuit-breaker-mcb-acti9-ic60n-1p-63a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73163 Acti9 iC60N MCB 1P 63 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73163 is a 1-pole Miniature Circuit Breaker (MCB) from the Acti 9 iC60N range, rated at 63 A with a B tripping curve. Suitable for both AC and DC networks, it delivers a breaking capacity of 6,000 A (Icn) at 230 V AC and 10 kA (Icu) at 220-240 V AC, making it well suited for electrical energy distribution applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73163\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current: 63 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 230 V AC 50\/60 Hz per IEC\/EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 220-240 V AC 50\/60 Hz per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7.5 kA at 220-240 V AC 50\/60 Hz per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: single terminal block, 1-35 mm² rigid \/ 1-25 mm² flexible, tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for use as an isolating device per IEC\/EN 60898-1 and IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eBuilt-in trip indicator for rapid fault identification without opening the enclosure\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003eRated for overvoltage category IV and pollution degree 3, suitable for demanding environments\u003c\/li\u003e\n  \u003cli\u003eTropicalized per IEC 60068-1, with 95% relative humidity tolerance at 55°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection in electrical energy distribution panels\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery system installations\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring overvoltage category IV protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 60898-1 and IEC\/EN 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73163, Schneider Electric A9F73163, iC60N 63A B curve MCB, Acti9 1-pole 63A miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065505673480,"sku":"SCHA9F73163","price":8.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73163-miniature-circuit-breaker-mcb-acti9-ic60n-1p-63a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-614030.jpg?v=1735230357"},{"product_id":"a9f74102-miniature-circuit-breaker-mcb-acti9-ic60n-1p-2a-c-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F74102 Acti9 iC60N MCB 1P 2 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74102 is a 1-pole miniature circuit breaker from the Acti 9 iC60N range, rated at 2 A with a C tripping curve. It provides thermomagnetic protection for AC and DC networks, with a breaking capacity of 6000 A Icn at 230 V AC per EN\/IEC 60898-1 and up to 50 kA Icu per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74102\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current: 2 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 230 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 50 kA at 220-240 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eQuality mark: NF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection covers overload and short-circuit conditions on both AC and DC networks.\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimises energy let-through, protecting downstream equipment and wiring.\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible on upper or lower connection, simplifying distribution panel assembly.\u003c\/li\u003e\n  \u003cli\u003eTrip indicator and contact position indicator provide clear local status monitoring.\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings.\u003c\/li\u003e\n  \u003cli\u003eCircuit protection in industrial low-voltage switchgear assemblies.\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems and solar PV installations.\u003c\/li\u003e\n  \u003cli\u003eControl panels requiring compact, high-performance overcurrent protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74102, Schneider Electric A9F74102, iC60N 2A C curve MCB, Acti9 1-pole miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065511473416,"sku":"SCHA9F74102","price":6.71,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74102-miniature-circuit-breaker-mcb-acti9-ic60n-1p-2a-c-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-467085.jpg?v=1735230350"},{"product_id":"a9f74104-miniature-circuit-breaker-mcb-acti9-ic60n-1p-4a-c-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"A9F74104 Schneider MCB, Acti9 iC60N, 1P, 4A, C curve, 6000A 50kA","description":"\u003cp\u003eThe Schneider Electric A9F74104 is a 1-pole miniature circuit breaker from the Acti 9 iC60N series, rated 4A with a C tripping curve. Its thermomagnetic protection unit delivers a breaking capacity of 6000A at 230V AC (EN\/IEC 60898-1) and 50 kA at 220-240V AC (EN\/IEC 60947-2), compatible with both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74104\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current: 4A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000A at 230V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 50 kA at 220-240V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at up to 72V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eUsage category: A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for clear local signaling\u003c\/li\u003e\n  \u003cli\u003eUpper or lower comb busbar connection supported for flexible wiring\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 for effective energy limiting during short-circuit events\u003c\/li\u003e\n  \u003cli\u003eNF quality certified for assured compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCircuit protection in residential and commercial final distribution boards\u003c\/li\u003e\n  \u003cli\u003eIndustrial control and automation panels on AC networks\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery-backed systems\u003c\/li\u003e\n  \u003cli\u003eCompact DIN rail switchboards and distribution panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74104, Schneider Electric A9F74104, iC60N 1P 4A C curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065512685832,"sku":"SCHA9F74104","price":5.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74104-miniature-circuit-breaker-mcb-acti9-ic60n-1p-4a-c-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-506698.jpg?v=1735230356"},{"product_id":"a9f74106-ic60n-miniature-circuit-breaker-1p-6a-c-curve","title":"Schneider A9F74106 Acti9 iC60N MCB 1P 6 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74106 is a 1-pole 6 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, with a C tripping curve and thermomagnetic trip technology for protection on both AC and DC distribution networks. Breaking capacity is 6,000 A Icn at 230 V AC per EN\/IEC 60898-1 and 10 kA Icu at 220-240 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74106\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 6 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6,000 A at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 7,500 A (75%) at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (upper or lower), 1-25 mm² rigid \/ 1-16 mm² flexible; strip length 14 mm; torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic trip unit provides reliable protection against both overload and short-circuit faults\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003eTrip indicator and contact position indicator allow quick local fault diagnosis\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimises let-through energy during short-circuit events\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and light commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting, socket-outlet, and small appliance circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and switchboard assemblies\u003c\/li\u003e\n  \u003cli\u003eDC distribution in renewable energy and battery storage systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74106, Schneider Electric A9F74106, iC60N 6A C curve MCB, Acti9 1P 6A miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065512882440,"sku":"SCHA9F74106","price":3.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74106-ic60n-miniature-circuit-breaker-1p-6a-c-curve-298514.jpg?v=1735230349"},{"product_id":"a9f74110-miniature-circuit-breaker-mcb-acti9-ic60n-1p-10a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74110 Acti9 iC60N MCB 1P 10 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74110 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, designed for electrical power distribution. It provides thermomagnetic protection with a C tripping curve and a rated current of 10 A, suitable for both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74110\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 10 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 72 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 15 kA at 12-60 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-2, EN 60947-2, EN 60898-1, IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection with C curve for reliable overload and short-circuit detection\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks, offering installation flexibility\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible from top or bottom for simplified distribution board wiring\u003c\/li\u003e\n  \u003cli\u003eTrip position indicator and handle-operated control for clear status visibility\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70 °C for demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial electrical installations\u003c\/li\u003e\n  \u003cli\u003eProtection of circuits in industrial control panels and switchgear\u003c\/li\u003e\n  \u003cli\u003eDC applications in photovoltaic and battery-backed systems (up to 72 V DC)\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting, socket, and small power circuits\u003c\/li\u003e\n  \u003cli\u003eLow-voltage panel assemblies requiring compact DIN rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-2, EN 60947-2, EN 60898-1, and IEC 60898-1. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74110, Schneider Electric A9F74110, Acti9 iC60N 10A MCB, Schneider 1-pole 10A C-curve circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065513701640,"sku":"SCHA9F74110","price":3.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74110-miniature-circuit-breaker-mcb-acti9-ic60n-1p-10a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-181659.jpg?v=1735230355"},{"product_id":"a9f74116-miniature-circuit-breaker-mcb-acti9-ic60n-1p-16a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74116 Acti9 iC60N MCB 1P 16 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74116 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 16 A with a C tripping curve. It delivers thermomagnetic overcurrent protection for AC and DC networks, achieving 6,000 A Icn at 230 V AC per EN\/IEC 60898-1 and 10 kA Icu at 220-240 V AC per EN\/IEC 60947-2. Approved for use as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74116\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current: 16 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1-25 mm² solid \/ 1-16 mm² flexible (upper or lower)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStandards: EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection unit delivers reliable overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eC tripping curve designed for loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eApproved as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting with comb busbar connection block support (upper or lower)\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance of 20,000 cycles and electrical endurance of 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection in electrical distribution panels\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in solar and battery storage installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74116, Schneider Electric A9F74116, Acti9 iC60N 16A MCB, 1-pole C curve miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065513767176,"sku":"SCHA9F74116","price":2.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74116-miniature-circuit-breaker-mcb-acti9-ic60n-1p-16a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-504841.jpg?v=1735230353"},{"product_id":"a9f74120-ic60n-miniature-circuit-breaker-1p-20a-c-curve","title":"Schneider A9F74120 Acti9 iC60N MCB 1P 20 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74120 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 20 A with a C tripping curve. It provides thermomagnetic overcurrent protection for AC and DC networks, with a breaking capacity of 6,000 A Icn at 230 V AC per EN\/IEC 60898-1 and 10 kA Icu at 220-240 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74120\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 20 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 230 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 220-240 V AC 50\/60 Hz; 36 kA at 12-60 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1-25 mm² rigid \/ 1-16 mm² flexible; tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles; electrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection unit operates across both AC and DC networks\u003c\/li\u003e\n  \u003cli\u003eTrip indicator enables quick local fault identification\u003c\/li\u003e\n  \u003cli\u003eContact position indicator provides clear open\/closed status at a glance\u003c\/li\u003e\n  \u003cli\u003eCompatible with upper or lower comb busbar distribution blocks\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy and protects downstream equipment\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control and automation panels with AC or DC supply\u003c\/li\u003e\n  \u003cli\u003eLow-voltage electrical energy distribution systems\u003c\/li\u003e\n  \u003cli\u003eDIN rail enclosures requiring compact single-pole circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74120, Schneider Electric A9F74120, iC60N 20A C curve MCB, Acti9 1-pole 20A miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065513898248,"sku":"SCHA9F74120","price":2.97,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74120-ic60n-miniature-circuit-breaker-1p-20a-c-curve-205914.jpg?v=1735230354"},{"product_id":"a9f74125-miniature-circuit-breaker-mcb-acti9-ic60n-1p-25a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74125 Acti9 iC60N MCB 1P 25 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74125 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 25 A with a C tripping curve. It provides thermal-magnetic protection for AC and DC distribution circuits with a breaking capacity of 10 kA at 220-240 V AC under IEC\/EN 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74125\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 25 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 230 V AC 50\/60 Hz (EN\/IEC 60898-1); 10 kA Icu at 220-240 V AC 50\/60 Hz (EN\/IEC 60947-2); 10 kA Icu at 72 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve thermal-magnetic trip unit suitable for loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks (top or bottom)\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for quick visual diagnostics\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm width optimises space in distribution boards\u003c\/li\u003e\n  \u003cli\u003eRated for both AC and DC networks, expanding installation flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal circuit protection in residential and commercial electrical distribution boards\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and socket outlet circuits in buildings\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery storage installations\u003c\/li\u003e\n  \u003cli\u003eIndustrial panel boards requiring compact DIN rail mounted overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74125, Schneider Electric A9F74125, iC60N 1P 25A C curve MCB, Acti9 miniature circuit breaker 25A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065514651912,"sku":"SCHA9F74125","price":3.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74125-miniature-circuit-breaker-mcb-acti9-ic60n-1p-25a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-783447.jpg?v=1735230357"},{"product_id":"a9f74132-ic60n-miniature-circuit-breaker-1p-32a-c-curve","title":"Schneider A9F74132 Acti9 iC60N MCB 1P 32 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74132 is a single-pole 32 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, providing thermomagnetic overcurrent protection with a C tripping characteristic. It delivers a breaking capacity of 10 kA at 220-240 V AC per IEC 60947-2, making it suitable for high-demand distribution applications. Compatible with both AC and DC networks, it is certified as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74132\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 32 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTripping unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eOvercurrent trip threshold: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-35 mm² rigid \/ 1-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection delivers reliable overload and short-circuit response in a single compact device.\u003c\/li\u003e\n  \u003cli\u003eApproved as an isolating device, eliminating the need for a separate isolator in many installations.\u003c\/li\u003e\n  \u003cli\u003eVisual trip indicator and contact position indicator provide immediate local fault status feedback.\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block compatible at top or bottom, simplifying multi-circuit panel wiring.\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 design reduces let-through energy, protecting downstream equipment from thermal stress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings.\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and socket-outlet circuits in low-voltage panels.\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection in industrial control and automation panels.\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery-backed systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74132, Schneider Electric A9F74132, iC60N 32A C curve MCB, Acti9 1P 32A breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515143432,"sku":"SCHA9F74132","price":4.07,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74132-ic60n-miniature-circuit-breaker-1p-32a-c-curve-947496.jpg?v=1735230349"},{"product_id":"a9f74140-miniature-circuit-breaker-mcb-acti9-ic60n-1p-40a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74140 Acti9 iC60N MCB 1P 40 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74140 is a 1-pole, 40 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, designed for electrical distribution on AC and DC networks. Its thermomagnetic C tripping curve and ultimate breaking capacity (Icu) of 10 kA at 220-240 V AC per IEC 60947-2 make it a reliable solution for general-purpose circuit protection in residential and commercial installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74140\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P; rated current: 40 A; tripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC; protection technology: thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 230 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 220-240 V AC 50\/60 Hz; 10 kA at 72 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7.5 kA at 220-240 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1); use category: A (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz; impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed; dimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg; color: white; IP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70°C; storage temperature: -40...85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1...35 mm² rigid \/ 1...25 mm² flexible; strip length: 14 mm; tightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV; pollution degree: 3; tropicalization: 2 (IEC 60068-1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve thermomagnetic protection suited to loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eDual AC and DC network compatibility in a single device\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimizes let-through energy, protecting downstream equipment\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator enables fast local fault identification\u003c\/li\u003e\n  \u003cli\u003eUpper or lower comb busbar block compatibility for flexible panel wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems up to 72 V\u003c\/li\u003e\n  \u003cli\u003eCircuits requiring overvoltage category IV protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74140, Schneider Electric A9F74140, iC60N 40A C curve MCB, Acti9 1-pole 40 amp circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515176200,"sku":"SCHA9F74140","price":5.06,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74140-miniature-circuit-breaker-mcb-acti9-ic60n-1p-40a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-631908.jpg?v=1735230349"},{"product_id":"a9f74150-miniature-circuit-breaker-mcb-acti9-ic60n-1p-50a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74150 Acti9 iC60N MCB 1P 50 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74150 is a 1-pole 50 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, equipped with a C tripping curve and thermomagnetic protection technology. It delivers a breaking capacity of 10 kA at 220-240 V AC per IEC 60947-2 and is rated for both AC and DC network applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74150\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current: 50 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 230 V AC 50\/60 Hz (IEC 60898-1); 10 kA Icu at 220-240 V AC 50\/60 Hz (IEC 60947-2); 15 kA Icu at 12-60 V DC (IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-35 mm² rigid \/ 1-25 mm² flexible; strip length 14 mm; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60898-1, IEC 60947-2, EN 60898-1, EN 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eApproved for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with busbar comb distribution systems, upper or lower connection, 9 mm pitch\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator for clear local fault signalling\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category IV and pollution degree 3 for demanding industrial environments\u003c\/li\u003e\n  \u003cli\u003eTropicalization class 2 per IEC 60068-1 for high-humidity conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eSub-distribution and industrial panels requiring high breaking capacity\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery storage systems\u003c\/li\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection for cables and connected equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, IEC 60947-2, EN 60898-1, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74150, Schneider Electric A9F74150, iC60N 1P 50A MCB, 1-pole 50 A C curve miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515241736,"sku":"SCHA9F74150","price":8.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74150-miniature-circuit-breaker-mcb-acti9-ic60n-1p-50a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-384202.jpg?v=1735230357"},{"product_id":"a9f74163-ic60n-miniature-circuit-breaker-1p-63a-c-curve","title":"Schneider A9F74163 Acti9 iC60N MCB 1P 63 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74163 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 63 A with a C tripping curve for thermomagnetic overload and short-circuit protection. Compatible with both AC and DC networks, it delivers a breaking capacity of 10 kA at 220-240 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74163\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current: 63 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 230 V AC 50\/60 Hz (IEC\/EN 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 220-240 V AC; 36 kA at 12-60 V AC; 15 kA at 12-60 V DC; 10 kA at 72 V DC (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7.5 kA at 220-240 V AC; 27 kA at 12-60 V AC (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC 50\/60 Hz (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eUse category: A (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3 (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-35 mm² rigid \/ 1-25 mm² flexible; strip length 14 mm; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection technology responds reliably to both sustained overloads and short-circuit faults\u003c\/li\u003e\n  \u003cli\u003eRated for use as an isolating device per IEC\/EN 60898-1 and IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible (upper or lower connection) for straightforward distribution board assembly\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy, protecting downstream components and wiring\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator provide clear local circuit status monitoring\u003c\/li\u003e\n  \u003cli\u003eSuitable for DC networks including up to 72 V DC, broadening installation flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial switchboards and control panels\u003c\/li\u003e\n  \u003cli\u003eDC power distribution in renewable energy and battery storage systems\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring overvoltage category IV and pollution degree 3 compliance\u003c\/li\u003e\n  \u003cli\u003eCircuits where class 3 energy limitation is needed to safeguard sensitive downstream equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 60898-1 and IEC\/EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74163, Schneider Electric A9F74163, iC60N 1P 63A C curve MCB, Acti9 miniature circuit breaker 63A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515307272,"sku":"SCHA9F74163","price":9.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74163-ic60n-miniature-circuit-breaker-1p-63a-c-curve-289156.jpg?v=1735230426"},{"product_id":"a9k01106-miniature-circuit-breaker-mcb-acti9-k60n-1p-6a-b-curve-6000a-iec-en-60898-1","title":"Schneider A9K01106 Acti9 K60N MCB 1P 6 A B Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K01106 is a 1-pole, 6 A miniature circuit breaker (MCB) from the Acti 9 K60N range with a B tripping curve. It delivers thermomagnetic overcurrent protection for AC circuits, with a breaking capacity of 6000 A at 230 V AC per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K01106\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current: 6 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 230 V AC\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 6000 A (100%) at 230 V AC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -25...85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals, 0.5...35 mm² rigid \/ 0.5...25 mm² flexible, tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical \/ electrical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: VDE, OVE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection guards against both thermal overload and short-circuit faults in a single device\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics) equals Icn at 100%, ensuring full performance is maintained throughout service life\u003c\/li\u003e\n  \u003cli\u003eApproved for use as an isolating device per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm width enables space-efficient DIN rail panel layouts\u003c\/li\u003e\n  \u003cli\u003eWide operating range of -25...70°C suits installation in demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and light commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting, socket, and resistive load branch circuits\u003c\/li\u003e\n  \u003cli\u003eCable protection in low-voltage AC distribution and control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1, certified by VDE and OVE. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K01106, Schneider Electric A9K01106, Acti9 K60N 6A B curve MCB, K60N 1P miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065528021256,"sku":"SCHA9K01106","price":1.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k01106-miniature-circuit-breaker-mcb-acti9-k60n-1p-6a-b-curve-6000a-iecen-60898-1-859330.jpg?v=1735230866"},{"product_id":"a9k01110-miniature-circuit-breaker-mcb-acti9-k60n-1p-10a-b-curve-6000a-iec-en-60898-1","title":"Schneider A9K01110 Acti9 K60N MCB 1P 10 A B Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K01110 is a 1-pole, 10 A miniature circuit breaker (MCB) from the Acti 9 K60N range, featuring a B tripping curve and a breaking capacity of 6000 A Icn at 230 V AC 50\/60 Hz. It uses thermomagnetic protection technology on AC networks and is approved for isolation duty per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K01110\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eDevice type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 10 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 230 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 230 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 3...5 x In\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail (fixed)\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type, 0.5...35 mm² rigid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical \/ electrical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: VDE, OVE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB curve tripping characteristic delivers sensitive protection for resistive and lighting circuits with low inrush currents.\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity equals rated breaking capacity (Ics = Icn = 6000 A) - no derating required in service conditions.\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy, protecting sensitive downstream equipment during fault events.\u003c\/li\u003e\n  \u003cli\u003eLower double-connection busbar distribution block enables fast comb busbar wiring in multi-circuit panels.\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25...70°C suits demanding installation environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and apartment buildings.\u003c\/li\u003e\n  \u003cli\u003eCommercial electrical panels protecting lighting and socket outlet circuits.\u003c\/li\u003e\n  \u003cli\u003eIndustrial and commercial control cabinets requiring compact branch circuit protection.\u003c\/li\u003e\n  \u003cli\u003eModular DIN rail assemblies in multi-circuit distribution boards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K01110, Schneider Electric A9K01110, K60N 1P 10A B curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065528054024,"sku":"SCHA9K01110","price":1.81,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k01110-miniature-circuit-breaker-mcb-acti9-k60n-1p-10a-b-curve-6000a-iecen-60898-1-577977.jpg?v=1735230871"},{"product_id":"a9k01116-miniature-circuit-breaker-mcb-acti9-k60n-1p-16a-b-curve-6000a-iec-en-60898-1","title":"Schneider A9K01116 Acti9 K60N MCB 1P 16 A B Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K01116 is a 1-pole Miniature Circuit Breaker (MCB) from the Acti 9 K60N series, rated at 16 A with a B tripping curve and 6 kA breaking capacity at 230 V AC. Designed for electrical power distribution on DIN rail, it provides thermomagnetic overcurrent protection for AC networks in residential and light commercial installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K01116\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: K60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 16 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 3...5 x In\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm (1 x 9 mm module)\u003c\/li\u003e\n  \u003cli\u003eHeight: 81 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eConnection terminals (upper\/lower): 0.5...35 mm² rigid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -25...85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: VDE, OVE\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB tripping curve suits resistive and slightly inductive loads with low inrush currents, minimizing nuisance tripping\u003c\/li\u003e\n  \u003cli\u003e6 kA breaking capacity at 230 V AC ensures reliable fault clearance in standard distribution networks\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm (1 module) width maximizes panel space efficiency on DIN rail installations\u003c\/li\u003e\n  \u003cli\u003eDouble connection on lower comb busbar terminal enables flexible wiring configurations\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation duty per EN\/IEC 60898-1, replacing the need for a separate isolation device\u003c\/li\u003e\n  \u003cli\u003eHalogen-free product supporting environmentally responsible installation practices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential buildings for circuit protection of lighting and socket circuits\u003c\/li\u003e\n  \u003cli\u003eLight commercial electrical panels where low inrush loads require B curve protection\u003c\/li\u003e\n  \u003cli\u003eSub-distribution boards in industrial facilities for auxiliary circuit protection\u003c\/li\u003e\n  \u003cli\u003eElectrical power distribution systems requiring DIN rail mounted overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1, Usage Category A per IEC 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K01116, Schneider Electric A9K01116, Acti9 K60N 1P 16A MCB, Schneider 16A B-curve circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065528086792,"sku":"SCHA9K01116","price":1.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k01116-miniature-circuit-breaker-mcb-acti9-k60n-1p-16a-b-curve-6000a-iecen-60898-1-906843.jpg?v=1735230863"},{"product_id":"a9k01120-miniature-circuit-breaker-mcb-acti9-k60n-1p-20a-b-curve-6000a-iec-en-60898-1","title":"Schneider A9K01120 Acti9 K60N MCB 1P 20 A B Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K01120 is a 1-pole Miniature Circuit Breaker (MCB) from the Acti 9 K60N series, rated at 20 A with a B tripping curve. It provides thermomagnetic overcurrent protection with a 6000 A breaking capacity at 230 V AC, making it well suited for final distribution in residential and commercial installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K01120\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 20 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eOvercurrent trip threshold: 3-5 x In\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 230 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 230 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eProtective unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -25...85°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel terminals, 0.5-35 mm² rigid \/ 0.5-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eCertifications: VDE, OVE\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eIcs equals 100% of Icn, providing full-rated breaking capacity for service conditions\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1, allowing use as a disconnect device\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar for streamlined wiring in distribution boards\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm width (2 x 9 mm pitch) conserves panel space\u003c\/li\u003e\n  \u003cli\u003eHalogen-free construction per product environmental profile\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and light commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and socket-outlet circuits\u003c\/li\u003e\n  \u003cli\u003eDIN rail assemblies in switchgear enclosures\u003c\/li\u003e\n  \u003cli\u003eLoad circuits requiring low-inrush B-curve protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 K60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K01120, Schneider Electric A9K01120, Acti9 K60N 1P 20A MCB, single-pole miniature circuit breaker B curve 6kA.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065528217864,"sku":"SCHA9K01120","price":1.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k01120-miniature-circuit-breaker-mcb-acti9-k60n-1p-20a-b-curve-6000a-iecen-60898-1-799921.jpg?v=1735230867"},{"product_id":"a9k01125-miniature-circuit-breaker-mcb-acti9-k60n-1p-25a-b-curve-6000a-iec-en-60898-1","title":"Schneider A9K01125 Acti9 K60N MCB 1P 25 A B Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K01125 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 K60N range, rated at 25 A with a B tripping curve and a breaking capacity of 6000 A at 230 V AC. Designed for electrical energy distribution, it features thermomagnetic protection technology and is approved for use as an isolation device per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K01125\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 25 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 230 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 230 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 18 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type, 0.5...35 mm² rigid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB tripping curve suited to loads where avoiding nuisance tripping is essential\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics) equals 100% of rated breaking capacity (Icn) at 230 V AC - no derating required\u003c\/li\u003e\n  \u003cli\u003eApproved for use as an isolation device per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eDouble connection on lower busbar comb enables flexible distribution wiring\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25 to 70°C suitable for demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and socket outlet circuits\u003c\/li\u003e\n  \u003cli\u003eDIN rail modular distribution panels in industrial and commercial enclosures\u003c\/li\u003e\n  \u003cli\u003eInstallations with sensitive loads requiring a B tripping characteristic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K01125, Schneider Electric A9K01125, Acti9 K60N 25A 1P B curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065528283400,"sku":"SCHA9K01125","price":1.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k01125-miniature-circuit-breaker-mcb-acti9-k60n-1p-25a-b-curve-6000a-iecen-60898-1-912459.jpg?v=1735230869"},{"product_id":"a9k01132-miniature-circuit-breaker-mcb-acti9-k60n-1p-32a-b-curve-6000a-iec-en-60898-1","title":"Schneider A9K01132 Acti9 K60N MCB 1P 32 A B Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K01132 is a 1-pole Miniature Circuit Breaker (MCB) from the Acti 9 K60N range, rated at 32 A with a B tripping curve and a breaking capacity of 6000 A at 230 V AC. Designed for electrical power distribution, it provides thermomagnetic overcurrent protection and is suitable for AC network types on 50\/60 Hz systems.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K01132\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: K60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current: 32 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A (Icn) at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 6000 A, 100% at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 3...5 x In\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation: Yes per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 81 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 70 mm\u003c\/li\u003e\n  \u003cli\u003eProduct weight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -25...85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2 per IEC\/EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: II\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eConnection type: Tunnel terminals - upper and lower, 0.5...35 mm² rigid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm (upper or lower)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m (upper or lower)\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB tripping curve for sensitive protection of circuits with low inrush currents, such as resistive loads and long cable runs\u003c\/li\u003e\n  \u003cli\u003e6000 A breaking capacity with 100% service breaking capacity (Ics = Icn), ensuring reliable fault clearance\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 for high energy limitation, reducing let-through current and protecting downstream equipment\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks for simplified and space-efficient panel wiring\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25...70 °C suitable for demanding installation environments\u003c\/li\u003e\n  \u003cli\u003eHalogen-free product compliant with EU RoHS directive, supporting environmental responsibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings for branch circuit protection\u003c\/li\u003e\n  \u003cli\u003eProtection of resistive loads and lighting circuits where B curve characteristics are required\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring compact 18 mm wide DIN rail mounted protection devices\u003c\/li\u003e\n  \u003cli\u003eElectrical distribution systems on AC networks at 230 V requiring reliable overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1, certified by OVE and VDE. Part of the Schneider Electric Acti 9 K60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K01132, Schneider Electric A9K01132, Acti9 K60N 32A MCB, 1-pole B curve circuit breaker 32A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065528348936,"sku":"SCHA9K01132","price":2.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k01132-miniature-circuit-breaker-mcb-acti9-k60n-1p-32a-b-curve-6000a-iecen-60898-1-199106.jpg?v=1735230863"},{"product_id":"a9k01140-miniature-circuit-breaker-mcb-acti9-k60n-1p-40a-b-curve-6000a-iec-en-60898-1","title":"Schneider A9K01140 Acti9 K60N MCB 1P 40 A B Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K01140 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 K60N series. Rated at 40 A with a B tripping curve and thermomagnetic protection, it provides a breaking capacity of 6 kA at 230 V AC per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K01140\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eMagnetic trip range: 3...5 x In\u003c\/li\u003e\n  \u003cli\u003eRated breaking capacity [Icn]: 6000 A at 230 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 230 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type (upper and lower), 0.5-35 mm² rigid \/ 0.5-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eService breaking capacity (Ics) equals rated breaking capacity (Icn) at 100% - no derating under service conditions\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolation device per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 for effective current limiting during short-circuit events\u003c\/li\u003e\n  \u003cli\u003eWide conductor acceptance: 0.5-35 mm² rigid and 0.5-25 mm² flexible at upper and lower terminals\u003c\/li\u003e\n  \u003cli\u003eRated for 20,000 mechanical cycles and 10,000 electrical switching cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection for lighting circuits and socket outlet groups\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and compact DIN rail enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K01140, Schneider Electric A9K01140, Acti9 K60N 40A MCB, 1-pole 40A B-curve miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065528381704,"sku":"SCHA9K01140","price":2.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k01140-miniature-circuit-breaker-mcb-acti9-k60n-1p-40a-b-curve-6000a-iecen-60898-1-800003.jpg?v=1735230867"},{"product_id":"a9k02104-miniature-circuit-breaker-mcb-acti9-k60n-1p-4a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02104 Acti9 K60N MCB 1P 4 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K02104 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 K60N range, rated at 4 A with a C tripping curve. It provides thermomagnetic overcurrent protection for AC distribution circuits, with a breaking capacity of 6000 A at 230 V AC.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02104\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current: 4 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 230 V AC 50\/60 Hz, per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 6000 A (100%) at 230 V AC 50\/60 Hz, per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5 to 10 x In\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3, per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A, per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm (2 x 9 mm modules)\u003c\/li\u003e\n  \u003cli\u003eHeight: 81 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20, per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals, 0.5 to 35 mm² rigid \/ 0.5 to 25 mm² flexible (top and bottom)\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eCertifications: VDE, OVE\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve characteristic suitable for loads with moderate inrush currents such as resistive and light inductive loads\u003c\/li\u003e\n  \u003cli\u003e100% rated service breaking capacity (Ics = Icn) ensures maximum reliability without derating\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm width minimizes panel space while providing full single-pole protection\u003c\/li\u003e\n  \u003cli\u003eDouble connection on the busbar comb distribution block terminals enables flexible wiring configurations\u003c\/li\u003e\n  \u003cli\u003eHalogen-free construction and minimum 56% recycled plastic content support environmental compliance\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25 to 70 °C suits demanding installation environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and resistive load circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring compact DIN rail-mounted overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eLow-voltage electrical distribution systems operating on AC networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02104, Schneider Electric A9K02104, Acti9 K60N 1P 4A C curve MCB, Schneider 4A miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065531429128,"sku":"SCHA9K02104","price":2.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02104-miniature-circuit-breaker-mcb-acti9-k60n-1p-4a-c-curve-6000a-iecen-60898-1-176091.jpg?v=1735230863"},{"product_id":"a9k02106-miniature-circuit-breaker-mcb-acti9-k60n-1p-6a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02106 Acti9 K60N MCB 1P 6 A C Curve 6kA DIN Rail","description":"\u003cp\u003eSchneider Electric A9K02106 is a 1-pole Miniature Circuit Breaker (MCB) from the Acti 9 K60N series, designed for electrical power distribution. It provides thermomagnetic overcurrent protection with a C tripping curve at 6 A rated current and a breaking capacity of 6000 A at 230 V AC.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02106\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: K60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 6 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 6000 A (100%) at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eLimiting class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 81 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection (upper\/lower): Tunnel terminals 0.5...35 mm² rigid, 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: VDE, OVE\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection technology provides reliable response to both overload and short-circuit conditions\u003c\/li\u003e\n  \u003cli\u003eC curve characteristic suits resistive and low-inductive loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003e100% service breaking capacity (Ics = Icn) ensures consistent performance over the device lifetime\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm width allows high-density installation in distribution boards\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1, enabling safe maintenance procedures\u003c\/li\u003e\n  \u003cli\u003eHalogen-free construction and minimum 56% recycled plastic content support environmental compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and general purpose socket outlet circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring compact DIN rail mounted overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eElectrical power distribution switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 K60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02106, Schneider Electric A9K02106, Acti9 K60N 1P 6A MCB, miniature circuit breaker 6A C curve 6kA.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065531461896,"sku":"SCHA9K02106","price":2.09,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02106-miniature-circuit-breaker-mcb-acti9-k60n-1p-6a-c-curve-6000a-iecen-60898-1-258921.jpg?v=1735230867"},{"product_id":"a9k02110-miniature-circuit-breaker-mcb-acti9-k60n-1p-10a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02110 Acti9 K60N MCB 1P 10 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K02110 is a 1-pole 10 A miniature circuit breaker (MCB) from the Acti 9 K60N series, with a C tripping curve and a breaking capacity of 6000 A at 230 V AC. It provides thermomagnetic overcurrent and short-circuit protection for final AC distribution circuits in residential and commercial installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02110\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 10 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 230 V AC (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A, 100% of Icn at 230 V AC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent trip range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals, 0.5...35 mm² rigid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm; tightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical and electrical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection provides reliable tripping against both overload and short-circuit currents.\u003c\/li\u003e\n  \u003cli\u003eC tripping curve with magnetic trip range of 5 to 10 x In suits loads with moderate inrush currents such as lighting and resistive circuits.\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics) equals 100% of Icn, ensuring consistent protection across the full product lifetime.\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm single-pole width (2 x 9 mm DIN pitch) minimizes space in the distribution board.\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and light commercial buildings.\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and power circuits in consumer units and distribution panels.\u003c\/li\u003e\n  \u003cli\u003eSingle-pole overcurrent protection in low-voltage switchboards and control cabinets.\u003c\/li\u003e\n  \u003cli\u003eIndustrial and commercial electrical installations on 230 V AC systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 K60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02110, Schneider Electric A9K02110, Acti9 K60N 1P 10A C curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065531527432,"sku":"SCHA9K02110","price":1.88,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02110-miniature-circuit-breaker-mcb-acti9-k60n-1p-10a-c-curve-6000a-iecen-60898-1-572643.jpg?v=1735230866"},{"product_id":"a9k02116-miniature-circuit-breaker-mcb-acti9-k60n-1p-16a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02116 Acti9 K60N MCB 1P 16 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K02116 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 K60N range, rated 16 A with a type C tripping curve and a 6 kA breaking capacity at 230 V AC. Thermal-magnetic protection technology and isolation capability per EN\/IEC 60898-1 make it suitable for final circuit protection in AC power distribution.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02116\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 16 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 230 V AC 50\/60 Hz - EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 230 V AC 50\/60 Hz - EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 - EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A - IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 - IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type, 0.5...35 mm² rigid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eMechanical \/ electrical durability: 20,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFull service breaking capacity: Ics equals Icn at 6000 A (100%), no derating required after fault clearing.\u003c\/li\u003e\n  \u003cli\u003eType C tripping curve for loads with moderate inrush current, tripping between 5 and 10 x In.\u003c\/li\u003e\n  \u003cli\u003eIsolation-rated per EN\/IEC 60898-1, usable as a local disconnecting device without a separate isolator.\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm width (2 DIN modules) saves panel space in distribution boards and enclosures.\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25 to 70°C suits demanding installation environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal circuit protection in residential electrical distribution boards.\u003c\/li\u003e\n  \u003cli\u003eLighting and socket outlet circuits in commercial buildings.\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and switchboard branch circuit protection.\u003c\/li\u003e\n  \u003cli\u003eAC power distribution systems operating at 230 V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and certified to OVE and VDE standards. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02116, Schneider Electric A9K02116, K60N 16A MCB, Schneider 16A C-curve circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065532281096,"sku":"SCHA9K02116","price":1.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02116-miniature-circuit-breaker-mcb-acti9-k60n-1p-16a-c-curve-6000a-iecen-60898-1-740796.jpg?v=1735230863"},{"product_id":"a9k02120-miniature-circuit-breaker-mcb-acti9-k60n-1p-20a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02120 Acti9 K60N MCB 1P 20 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K02120 is a 1-pole Miniature Circuit Breaker (MCB) from the Acti 9 K60N range, rated at 20 A with a C tripping curve and 6 kA breaking capacity at 230 V AC. Designed for electrical power distribution, it provides thermomagnetic overcurrent protection for AC networks with reliable performance in residential and commercial installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02120\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: K60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current: 20 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A (Icn) at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 6000 A (100%) at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eDIN rail pitch: 9 mm, 2 modules\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2 per IEC\/EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: II\u003c\/li\u003e\n  \u003cli\u003eControl type: Toggle handle\u003c\/li\u003e\n  \u003cli\u003eConnection (upper\/lower): Tunnel terminals, rigid 0.5...35 mm², flexible 0.5...25 mm²\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC tripping curve suits loads with moderate inrush currents such as lighting circuits and general power distribution\u003c\/li\u003e\n  \u003cli\u003e6 kA breaking capacity (Icn) with 100% service breaking capacity (Ics) at 230 V AC ensures full protection without derating\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy, minimising stress on downstream equipment during fault conditions\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm wide, 1-module design maximises space efficiency in distribution boards\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting with lower double-connection busbar comb compatibility simplifies panel wiring\u003c\/li\u003e\n  \u003cli\u003eHalogen-free construction with 56% minimum recycled plastic content supports sustainability requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings for circuit protection\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and general socket outlet circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring compact DIN rail mounted overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eLow-voltage switchgear assemblies in power distribution applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 K60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02120, Schneider Electric A9K02120, Acti9 K60N 20A MCB, Schneider 1-pole MCB 20A C curve.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065532313864,"sku":"SCHA9K02120","price":1.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02120-miniature-circuit-breaker-mcb-acti9-k60n-1p-20a-c-curve-6000a-iecen-60898-1-641819.jpg?v=1735230871"},{"product_id":"a9k02125-miniature-circuit-breaker-mcb-acti9-k60n-1p-25a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02125 Acti9 K60N MCB 1P 25 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K02125 is a 1-pole 25 A miniature circuit breaker (MCB) from the Acti 9 K60N range, featuring a C tripping curve and a breaking capacity of 6000 A Icn. It provides thermomagnetic protection against overloads and short circuits in AC electrical distribution systems.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02125\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 25 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100% Icn) at 230 V AC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent trip range: 5-10 x In\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type, 0.5-35 mm² rigid \/ 0.5-25 mm² flexible (top and bottom)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 70°C\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve thermomagnetic protection suits loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eIcs equal to 100% Icn ensures full rated breaking performance throughout service life\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm (2-module) DIN rail footprint saves space in distribution boards\u003c\/li\u003e\n  \u003cli\u003eTunnel terminals accept 0.5-35 mm² rigid conductors for flexible wiring on both top and bottom\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as a circuit isolator per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated for operation from -25 to 70°C with 95% relative humidity at 55°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and socket-outlet circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control and automation panels\u003c\/li\u003e\n  \u003cli\u003eAC branch circuits requiring C curve overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02125, Schneider Electric A9K02125, Acti9 K60N 25A 1P MCB, Schneider 25A C curve circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065532379400,"sku":"SCHA9K02125","price":2.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02125-miniature-circuit-breaker-mcb-acti9-k60n-1p-25a-c-curve-6000a-iecen-60898-1-528119.jpg?v=1735230863"},{"product_id":"a9k02132-miniature-circuit-breaker-mcb-acti9-k60n-1p-32a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02132 Acti9 K60N MCB 1P 32 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K02132 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 K60N series, rated at 32 A with a C tripping curve and 6000 A breaking capacity at 230 V AC. Designed for electrical power distribution, it provides thermomagnetic protection for AC networks at 50\/60 Hz.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02132\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current: 32 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 6000 A (100%) at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm (2 x 9 mm modules)\u003c\/li\u003e\n  \u003cli\u003eHeight: 81 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection type: Tunnel terminals, rigid 0.5...35 mm², flexible 0.5...25 mm²\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection technology ensures reliable tripping against both overload and short-circuit conditions\u003c\/li\u003e\n  \u003cli\u003eC curve characteristic suitable for loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003e100% service breaking capacity (Ics = Icn) at 6000 A provides full-rated performance throughout the device lifetime\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm width (2 module) saves space in distribution boards\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks for simplified panel wiring\u003c\/li\u003e\n  \u003cli\u003eHalogen-free product supporting environmental compliance requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal electrical distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and general power circuits in low-voltage panels\u003c\/li\u003e\n  \u003cli\u003eIndustrial control cabinet circuit protection for equipment up to 32 A\u003c\/li\u003e\n  \u003cli\u003eSub-distribution boards requiring compact DIN rail mounted protection devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02132, Schneider Electric A9K02132, Acti9 K60N 32A MCB, Schneider 32A C curve circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065532641544,"sku":"SCHA9K02132","price":2.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02132-miniature-circuit-breaker-mcb-acti9-k60n-1p-32a-c-curve-6000a-iecen-60898-1-435989.jpg?v=1735230867"},{"product_id":"a9k02140-miniature-circuit-breaker-mcb-acti9-k60n-1p-40a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02140 Acti9 K60N MCB 1P 40 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K02140 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 K60N series, rated at 40 A with a C tripping curve and 6000 A breaking capacity at 230 V AC. It provides thermomagnetic overload and short-circuit protection for final distribution circuits and is certified suitable for isolation per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02140\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C, overcurrent range 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 230 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 230 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eConnections: Tunnel terminals 0.5...35 mm² rigid \/ 0.5...25 mm² flexible (upper and lower); strip length 14 mm; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles; electrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFull service breaking capacity - Ics equals Icn at 6000 A, eliminating the need to derate for service conditions\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy during fault events, protecting downstream equipment\u003c\/li\u003e\n  \u003cli\u003eCertified suitable for isolation per EN\/IEC 60898-1, allowing safe circuit de-energization for maintenance\u003c\/li\u003e\n  \u003cli\u003eLower busbar comb double connection supports flexible DIN rail panel assembly\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25 to 70°C suits demanding installation environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and socket outlet groups\u003c\/li\u003e\n  \u003cli\u003eSmall power distribution panels in light industrial installations\u003c\/li\u003e\n  \u003cli\u003eControl cabinets requiring compact DIN rail circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02140, Schneider Electric A9K02140, Acti9 K60N 40A 1-pole C-curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065532707080,"sku":"SCHA9K02140","price":2.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02140-miniature-circuit-breaker-mcb-acti9-k60n-1p-40a-c-curve-6000a-iecen-60898-1-377398.jpg?v=1735230863"},{"product_id":"a9k01113-miniature-circuit-breaker-mcb-acti9-k60n-1p-13a-b-curve-6000a-iec-en-60898-1","title":"Schneider A9K01113 Acti9 K60N MCB 1P 13 A B Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K01113 is a 1-pole Miniature Circuit Breaker (MCB) from the Acti 9 K60N series, rated at 13 A with a B tripping curve and 6 kA breaking capacity at 230 V AC. Designed for electrical power distribution, it provides thermomagnetic protection for AC network applications on DIN rail panels.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K01113\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: K60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 13 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 6000 A (100%) at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 3...5 x In\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm (1 x 9 mm module)\u003c\/li\u003e\n  \u003cli\u003eHeight: 81 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -25...85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2 per IEC\/EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: II\u003c\/li\u003e\n  \u003cli\u003eConnection type: Tunnel terminals (upper and lower), 0.5...35 mm² solid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: VDE, OVE\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB tripping curve provides sensitive overcurrent protection with instantaneous trip at 3-5 x In, suited to resistive and lightly inductive loads\u003c\/li\u003e\n  \u003cli\u003e6 kA breaking capacity (Icn) with 100% service breaking capacity (Ics) ensures reliable fault clearance\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm single-pole design minimises panel space on DIN rail installations\u003c\/li\u003e\n  \u003cli\u003eWide conductor range (0.5-35 mm² solid) simplifies wiring across varied installation sizes\u003c\/li\u003e\n  \u003cli\u003eDual comb busbar connection support on lower terminals enables fast multi-pole busbar assembly\u003c\/li\u003e\n  \u003cli\u003eHalogen-free construction and minimum 56% recycled plastic content support sustainable installation practices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits, socket outlets, and small appliance circuits\u003c\/li\u003e\n  \u003cli\u003eLow-voltage switchgear and panel assemblies requiring DIN rail mounted MCBs\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels with AC loads requiring precise thermomagnetic protection\u003c\/li\u003e\n  \u003cli\u003eSub-distribution in multi-tenant or mixed-use electrical installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K01113, Schneider Electric A9K01113, K60N 1P 13A B curve MCB, Acti9 miniature circuit breaker 13A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075504107784,"sku":"SCHA9K01113","price":1.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k01113-miniature-circuit-breaker-mcb-acti9-k60n-1p-13a-b-curve-6000a-iecen-60898-1-578297.jpg?v=1735230867"},{"product_id":"a9k02102-miniature-circuit-breaker-mcb-acti9-k60n-1p-2a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02102 Acti9 K60N MCB 1P 2 A C Curve 6kA DIN Rail","description":"\u003cp\u003eSchneider Electric A9K02102 is a 1-pole, 2 A miniature circuit breaker (MCB) from the Acti 9 K60N range, featuring a C tripping curve and a breaking capacity of 6000 A at 230 V AC. It delivers thermomagnetic overcurrent protection for AC distribution circuits and is suitable for use as an isolating device per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02102\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 2 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 230 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 18 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel terminals, 0.5...35 mm² rigid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical \/ electrical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eCertifications: VDE, OVE\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1, serving as a local disconnect without a separate isolator\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy, protecting sensitive downstream equipment\u003c\/li\u003e\n  \u003cli\u003eIcs equals Icn at 100% - full service breaking capacity with no derating\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm width occupies just 2 pitches in the 9 mm Acti 9 module system\u003c\/li\u003e\n  \u003cli\u003eWide -25 to 70°C operating range suits demanding industrial and outdoor enclosure applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal circuit overcurrent protection in residential and commercial distribution boards\u003c\/li\u003e\n  \u003cli\u003eLighting and small power outlet circuit protection in low-current installations\u003c\/li\u003e\n  \u003cli\u003eControl panel wiring protection in light industrial and building automation panels\u003c\/li\u003e\n  \u003cli\u003eSub-distribution boards where compact DIN rail MCBs are required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and IEC 60947-2. Part of the Schneider Electric Acti 9 K60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02102, Schneider Electric A9K02102, K60N 1P 2A C curve MCB, 6kA miniature circuit breaker 2A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075504173320,"sku":"SCHA9K02102","price":2.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02102-miniature-circuit-breaker-mcb-acti9-k60n-1p-2a-c-curve-6000a-iecen-60898-1-128270.jpg?v=1735230863"},{"product_id":"a9p54616-miniature-circuit-breaker-mcb-acti9-ic40n-1p-n-16a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9P54616 Acti9 iC40N MCB 1P+N 16A C Curve 10kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9P54616 is a 1P+N miniature circuit breaker from the Acti9 iC40N range, rated 16A C curve, 10kA. The iC40N is a compact 2-module (1P+N) RCBO-capable device that provides line and neutral switching in a single-pole-plus-neutral format for final circuit protection in domestic and commercial boards.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePart number: A9P54616\u003c\/li\u003e\n\u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli\u003eSeries: Acti9 iC40N\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current: 16A\u003c\/li\u003e\n\u003cli\u003eTripping curve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 10kA\u003c\/li\u003e\n\u003cli\u003eMounting: 35mm DIN rail, 18mm pitch\u003c\/li\u003e\n\u003cli\u003eStandards: IEC\/EN 60898-1, CE\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e1P+N in 2 modules - provides line and neutral protection in a compact 36mm width\u003c\/li\u003e\n\u003cli\u003e10kA breaking capacity - higher breaking capacity than standard 6kA devices for demanding circuits\u003c\/li\u003e\n\u003cli\u003eActi9 compatible - fits standard 18mm pitch distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection in domestic and commercial distribution boards requiring 1P+N switching\u003c\/li\u003e\n\u003cli\u003eCircuit protection where separate line and neutral breaking is required in a compact format\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Schneider A9P54616, Acti9 iC40N 1P+N 16A C curve, A9P54616 MCB 10kA 1P+N.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075723981064,"sku":"SCHA9P54616","price":10.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9p54616-miniature-circuit-breaker-mcb-acti9-ic40n-1pn-16a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-916152.jpg?v=1745850579"},{"product_id":"m9f43110-miniature-circuit-breaker-mcb-multi9-c60bp-1p-10a-d-curve-14ka-ul489-10ka-iec-en-60947-2","title":"Schneider M9F43110 Multi9 C60BP Miniature circuit breaker 1P D10A 14kA (UL489)","description":"\u003cp\u003eThe Schneider Electric M9F43110 is a 1-pole, 10 A miniature circuit breaker (MCB) from the Multi9 C60 range, designed for distribution applications with a D tripping curve and thermal-magnetic trip technology. It achieves a breaking capacity of 10 kA Icu at 240 V AC (EN\/IEC 60947-2) and 14 kA AIR at 240 V AC (UL 489), with support for both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: M9F43110\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Multi9 C60\u003c\/li\u003e\n  \u003cli\u003eDevice type: Miniature circuit-breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003ePoles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current: 10 A at 25°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: D\u003c\/li\u003e\n  \u003cli\u003eTrip unit: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage: 240 V \/ 415 V AC 50\/60 Hz; 60 V DC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 10 kA Icu at 240 V AC; 3 kA Icu at 415 V AC; 20 kA Icu at 60 V DC (EN\/IEC 60947-2); 14 kA AIR at 240 V AC (UL 489)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 12 x In +\/- 20% AC; 17 x In +\/- 20% DC\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 18 x 103 x 72 mm\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC 60529); IP40 in modular enclosure\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -30...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel type terminal, top or bottom, 1...25 mm² rigid \/ 1...16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles; electrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-2, UL 489, CSA C22.2 No 5, GB\/T 14048.2\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC, UL, CSA, CCC\u003c\/li\u003e\n  \u003cli\u003eWeight: 119 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eD tripping curve with magnetic threshold at 12 x In (AC) and 17 x In (DC) for demanding distribution circuits\u003c\/li\u003e\n  \u003cli\u003eDual AC\/DC network compatibility, including 60 V DC at 20 kA Icu breaking capacity\u003c\/li\u003e\n  \u003cli\u003ePadlockable toggle handle enabling lockout\/tagout on the installation\u003c\/li\u003e\n  \u003cli\u003eContact position indicator with ON\/OFF local signalling for fast status verification\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60947-2, eliminating the need for a separate isolator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eBranch circuit protection in industrial and commercial distribution switchboards\u003c\/li\u003e\n  \u003cli\u003eDC network protection up to 60 V in distribution panels\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring simultaneous UL 489 and IEC 60947-2 compliance\u003c\/li\u003e\n  \u003cli\u003eDistribution boards built to North American standards (UL 489 \/ CSA C22.2 No 5)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2, UL 489, CSA C22.2 No 5, and GB\/T 14048.2. Part of the Schneider Electric Multi9 C60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider M9F43110, Schneider Electric M9F43110, C60BP 1P D10A MCB, Multi9 miniature circuit breaker 10A D curve.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44106518692104,"sku":"SCHM9F43110","price":10.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/m9f43110-miniature-circuit-breaker-mcb-multi9-c60bp-1p-10a-d-curve-14ka-ul489-10ka-iecen-60947-2-516940.jpg?v=1735251538"},{"product_id":"262700-pl7-c4-1-miniature-circuit-breaker-1p-c4a-10ka","title":"Eaton 262700 PL7-C4\/1 MCB 1P 4 A C Curve 10kA DIN Rail","description":"\u003cp\u003eThe Eaton PL7-C4\/1 is a 1-pole, C-curve miniature circuit breaker from the Eaton Moeller series xPole range, rated 4 A with a 10 kA short-circuit breaking capacity per IEC\/EN 60898-1. Designed for residential and commercial switchgear, it occupies one DIN rail module at 17.6 mm wide and operates across -25 °C to 75 °C.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PL7-C4\/1\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 262700\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082627003\u003c\/li\u003e\n  \u003cli\u003ePoles: 1 (single-pole)\u003c\/li\u003e\n  \u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 4 A\u003c\/li\u003e\n  \u003cli\u003eRated switching capacity (IEC\/EN 60898-1): 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit breaking capacity (Icn) at 230 V: 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit breaking capacity (Icn) at 400 V: 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage (Ue): 230 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: III\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class: 3\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 75 °C\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross-section: 1-25 mm² (solid-core and multi-wired)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 17.6 x 82 x 71 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003ePower loss: 1.5 W\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation, current-dependent: 1.4 W\u003c\/li\u003e\n  \u003cli\u003eWidth: 1 modular spacing\u003c\/li\u003e\n  \u003cli\u003eCompliance: RoHS conform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e10 kA rated switching capacity at both 230 V and 400 V delivers robust short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class 3 minimises fault energy let-through to downstream equipment\u003c\/li\u003e\n  \u003cli\u003eAccepts 1-25 mm² solid-core and multi-wired conductors for flexible wiring\u003c\/li\u003e\n  \u003cli\u003eCompact 1-module width (17.6 mm) maximises DIN rail density in tight enclosures\u003c\/li\u003e\n  \u003cli\u003eEvery 1 °C rise in ambient temperature reduces current carrying capacity by 0.5%, enabling accurate derating\u003c\/li\u003e\n  \u003cli\u003eCompatible with additional accessories and auxiliary equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal circuit protection in residential distribution boards and consumer units\u003c\/li\u003e\n  \u003cli\u003eCommercial switchgear panels and sub-distribution boards\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category III panel assemblies\u003c\/li\u003e\n  \u003cli\u003eProtection of 4 A lighting, socket, and appliance circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 60898-1. Part of the Eaton Moeller series xPole switchgear range for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PL7-C4\/1, Eaton 262700, Eaton catalog 262700, Eaton model PL7-C4\/1, Eaton xPole MCB 4A C-curve, Eaton Moeller PL7 4A.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251471544584,"sku":"ETN262700","price":5.28,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/262700-pl7-c41-miniature-circuit-breaker-1p-c4a-10ka-630693.jpg?v=1735225322"},{"product_id":"262701-pl7-c6-1-miniature-circuit-breaker-1p-c6a-10ka","title":"Eaton 262701 PL7-C6\/1 MCB 1P 6 A C Curve 10kA DIN Rail","description":"\u003cp\u003eThe Eaton PL7-C6\/1 is a single-pole miniature circuit breaker from the Eaton Moeller xPole series, rated at 6 A with tripping characteristic C. It provides a rated switching capacity of 10 kA per IEC\/EN 60898-1, housed in a compact 17.6 mm wide single-module enclosure for residential and commercial distribution panels.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PL7-C6\/1\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 262701\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082627010\u003c\/li\u003e\n  \u003cli\u003ePoles: 1 (single-pole), tripping characteristic C\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 6 A\u003c\/li\u003e\n  \u003cli\u003eRated switching capacity (IEC\/EN 60898-1): 10 kA at 230 V and 400 V\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class: 3\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage (Ue): 230 V AC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V; impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category III, pollution degree 2, IP20\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to +75 °C\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross-section: 1 - 25 mm² (solid-core and multi-wired)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 17.6 x 82 x 71 mm; weight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 70.5 mm; power loss: 1.2 W\u003c\/li\u003e\n  \u003cli\u003eRoHS conform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e10 kA breaking capacity at both 230 V and 400 V delivers dependable short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class 3 reduces let-through energy, protecting downstream equipment\u003c\/li\u003e\n  \u003cli\u003eSingle-module 17.6 mm width conserves valuable DIN rail space in compact panels\u003c\/li\u003e\n  \u003cli\u003eWide -25 °C to +75 °C operating range suits varied installation environments\u003c\/li\u003e\n  \u003cli\u003eAccepts 1 - 25 mm² solid-core and multi-wired conductors for flexible wiring\u003c\/li\u003e\n  \u003cli\u003eCompatible with xPole additional accessories for expanded switchgear functionality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal circuit protection in residential consumer units and distribution boards\u003c\/li\u003e\n  \u003cli\u003eLighting and socket outlet circuits in commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring overvoltage category III devices\u003c\/li\u003e\n  \u003cli\u003eCompact DIN rail switchgear assemblies in offices and retail premises\u003c\/li\u003e\n  \u003cli\u003eSub-distribution boards in multi-occupancy residential developments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 60898-1. Part of the Eaton Moeller xPole switchgear range for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PL7-C6\/1, Eaton 262701, Eaton catalog 262701, Eaton model PL7-C6\/1, Eaton xPole PL7 6A 1-pole MCB.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251471642888,"sku":"ETN262701","price":3.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/262701-pl7-c61-miniature-circuit-breaker-1p-c6a-10ka-758976.jpg?v=1735225322"},{"product_id":"262702-pl7-c10-1-miniature-circuit-breaker-1p-c10a-10ka","title":"Eaton 262702 PL7-C10\/1 MCB 1P 10 A C Curve 10kA DIN Rail","description":"\u003cp\u003eThe Eaton PL7-C10\/1 is a single-pole 10 A type C miniature circuit breaker (MCB) from the Eaton Moeller series xPole range, delivering a rated short-circuit breaking capacity of 10 kA at 230 V AC per IEC\/EN 60898-1. Its compact 17.6 mm single-module housing fits standard DIN rail distribution boards for residential and commercial switchgear.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PL7-C10\/1\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 262702\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082627027\u003c\/li\u003e\n  \u003cli\u003eType: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1 (single-pole)\u003c\/li\u003e\n  \u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 10 A\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage (Ue): 230 V AC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn) at 230 V \/ 400 V: 10 kA\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class: 3\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: III\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to +75 °C\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 17.6 x 82 x 71 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross section: 1-25 mm² (solid-core and multi-wired)\u003c\/li\u003e\n  \u003cli\u003ePower loss: 1.5 W\u003c\/li\u003e\n  \u003cli\u003eCompliance: RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e10 kA breaking capacity at 230 V and 400 V provides robust short-circuit protection in both single- and three-phase systems\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class 3 minimises let-through energy during fault conditions, protecting downstream equipment\u003c\/li\u003e\n  \u003cli\u003eWide ambient temperature range of -25 °C to +75 °C suits demanding installation environments\u003c\/li\u003e\n  \u003cli\u003eSingle-module (17.6 mm) width maximises usable space in compact distribution boards\u003c\/li\u003e\n  \u003cli\u003eCompatible with additional xPole accessories, enabling expanded protection configurations\u003c\/li\u003e\n  \u003cli\u003eRoHS compliant for use in environmentally regulated installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal circuit overcurrent protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial switchgear panels and consumer units\u003c\/li\u003e\n  \u003cli\u003eLighting and socket outlet circuit protection\u003c\/li\u003e\n  \u003cli\u003eBuilding services and facility management installations\u003c\/li\u003e\n  \u003cli\u003eIndustrial control cabinets requiring compact single-pole protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 60898-1. Part of the Eaton Moeller series xPole switchgear range for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PL7-C10\/1, Eaton 262702, Eaton catalog 262702, Eaton model PL7-C10\/1, Eaton xPole MCB 10 A curve C, Eaton Moeller PL7 MCB.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251472003336,"sku":"ETN262702","price":2.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/262702-pl7-c101-miniature-circuit-breaker-1p-c10a-10ka-887138.jpg?v=1735225385"},{"product_id":"262704-pl7-c16-1-miniature-circuit-breaker-1p-c16a-10ka","title":"Eaton 262704 PL7-C16\/1 MCB 1P 16 A C Curve 10kA DIN Rail","description":"\u003cp\u003eThe Eaton PL7-C16\/1 is a single-pole miniature circuit breaker (MCB) from the Eaton Moeller series xPole range, rated at 16 A with a type C tripping characteristic for protection against overload and short-circuit currents. With a rated short-circuit breaking capacity of 10 kA at 230 V and current limiting class 3, it is designed for reliable protection in residential and commercial switchgear installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PL7-C16\/1\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 262704\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082627041\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1 (single-pole)\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 16 A\u003c\/li\u003e\n  \u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit breaking capacity (ICN) at 230 V: 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit breaking capacity (ICN) at 400 V: 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated switching capacity (IEC\/EN 60898-1): 10 kA\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class: 3\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage (UE) max: 230 V AC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (UI): 440 V\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: III\u003c\/li\u003e\n  \u003cli\u003eFrequency rating: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to +75 °C\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross-section (solid-core): 1 - 25 mm²\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross-section (multi-wired): 1 - 25 mm²\u003c\/li\u003e\n  \u003cli\u003eWidth: 1 modular spacing (17.6 mm)\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 17.6 x 82 x 71 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 70.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eEquipment heat dissipation (current-dependent): 2.2 W\u003c\/li\u003e\n  \u003cli\u003ePower loss: 2.3 W\u003c\/li\u003e\n  \u003cli\u003eCompliances: RoHS conform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh 10 kA breaking capacity at 230 V and 400 V ensures safe fault clearance in demanding installations\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class 3 reduces let-through energy, protecting downstream equipment\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25 °C to +75 °C suits diverse installation environments\u003c\/li\u003e\n  \u003cli\u003eSingle modular spacing (17.6 mm) maximises panel density in space-critical enclosures\u003c\/li\u003e\n  \u003cli\u003eCompatible with additional accessories for expanded functionality within the xPole system\u003c\/li\u003e\n  \u003cli\u003eRoHS-compliant design supports environmentally responsible installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal circuit protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eLighting and socket-outlet circuit protection in commercial switchgear panels\u003c\/li\u003e\n  \u003cli\u003eOverload and short-circuit protection on DIN rail assemblies\u003c\/li\u003e\n  \u003cli\u003eSwitchgear for residential and commercial building installations\u003c\/li\u003e\n  \u003cli\u003eProtection of general-purpose AC loads requiring a type C response characteristic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 60898-1. Part of the Eaton Moeller series xPole family of protective devices for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PL7-C16\/1, Eaton 262704, Eaton catalog 262704, Eaton model PL7-C16\/1, Eaton xPole MCB 16A 1P curve C, PL7 C16 1 pole MCB.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251472265480,"sku":"ETN262704","price":3.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/262704-pl7-c161-miniature-circuit-breaker-1p-c16a-10ka-988522.jpg?v=1735225384"},{"product_id":"262705-pl7-c20-1-miniature-circuit-breaker-1p-c20a-10ka","title":"Eaton 262705 PL7-C20\/1 MCB 1P 20 A C Curve 10kA DIN Rail","description":"\u003cp\u003eThe Eaton PL7-C20\/1 is a 20 A single-pole type C miniature circuit breaker from the Eaton Moeller series xPole, rated at 10 kA short-circuit breaking capacity at 230 V (IEC\/EN 60898-1). Its single 17.6 mm module width makes it a compact solution for residential and commercial DIN rail panels.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PL7-C20\/1\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 262705\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082627058\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1 (single-pole)\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 20 A\u003c\/li\u003e\n  \u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n  \u003cli\u003eMax operational voltage (Ue): 230 V AC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eShort-circuit breaking capacity (Icn): 10 kA at 230 V and 400 V\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class: 3\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: III\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003eAmbient temperature: -25 °C to +75 °C\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 17.6 x 82 x 71 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 70.5 mm\u003c\/li\u003e\n  \u003cli\u003eModule width: 1 modular spacing\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eConductor cross section: 1-25 mm² (solid and flexible)\u003c\/li\u003e\n  \u003cli\u003ePower loss: 3.3 W\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation (current-dependent): 3.2 W\u003c\/li\u003e\n  \u003cli\u003eCompliances: RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e10 kA breaking capacity at 230 V with current limiting class 3 reduces let-through energy to downstream devices\u003c\/li\u003e\n  \u003cli\u003eType C tripping characteristic for general-purpose residential and commercial circuit protection\u003c\/li\u003e\n  \u003cli\u003eWide ambient temperature range (-25 °C to +75 °C) suits demanding installation environments\u003c\/li\u003e\n  \u003cli\u003eSingle modular width (17.6 mm) conserves DIN rail space in compact distribution boards\u003c\/li\u003e\n  \u003cli\u003eCompatible with additional xPole accessories for flexible panel configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eBranch circuit protection in residential distribution boards and consumer units\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection in commercial switchgear and DIN rail panels\u003c\/li\u003e\n  \u003cli\u003eLighting and socket outlet circuit protection in residential buildings\u003c\/li\u003e\n  \u003cli\u003eBuilding services installations in offices, retail units, and light commercial premises\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 60898-1. Part of the Eaton Moeller series xPole range for residential and commercial switchgear.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PL7-C20\/1, Eaton 262705, Eaton catalog 262705, Eaton model PL7-C20\/1, xPole MCB 20A type C.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251472331016,"sku":"ETN262705","price":3.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/262705-pl7-c201-miniature-circuit-breaker-1p-c20a-10ka-882258.jpg?v=1735225384"},{"product_id":"262706-pl7-c25-1-miniature-circuit-breaker-1p-c25a-10ka","title":"Eaton 262706 PL7-C25\/1 MCB 1P 25 A C Curve 10kA DIN Rail","description":"\u003cp\u003eThe Eaton PL7-C25\/1 is a 25 A single-pole type C miniature circuit breaker (MCB) from the Moeller series xPole range, rated for residential and commercial switchgear. It provides a rated short-circuit breaking capacity (Icn) of 10 kA at 230 V and current limiting class 3, accepting solid-core and multi-wired conductors from 1 to 25 mm².\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PL7-C25\/1\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 262706\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082627065\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1 (single-pole)\u003c\/li\u003e\n  \u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit breaking capacity (Icn) at 230 V: 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit breaking capacity (Icn) at 400 V: 10 kA\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class: 3\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage (Ue): 230 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: III\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to +75 °C\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross-section (solid-core): 1-25 mm²\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross-section (multi-wired): 1-25 mm²\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 17.6 x 82 x 71 mm\u003c\/li\u003e\n  \u003cli\u003eWidth: 1 modular spacing\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003ePower loss: 2.8 W\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation (current-dependent): 3 W\u003c\/li\u003e\n  \u003cli\u003eCompliances: RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e10 kA rated breaking capacity at 230 V (current limiting class 3) for reliable short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eWide operating range: -25 °C to +75 °C, with 0.5% current derating per 1 °C rise above reference\u003c\/li\u003e\n  \u003cli\u003eSingle modular spacing (17.6 mm wide) minimises panel space consumption\u003c\/li\u003e\n  \u003cli\u003eAccepts both solid-core and multi-wired conductors from 1 to 25 mm² for installation flexibility\u003c\/li\u003e\n  \u003cli\u003eCompatible with additional xPole accessories for extended protection configurations\u003c\/li\u003e\n  \u003cli\u003eRoHS compliant, meeting current environmental requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential distribution boards and consumer units\u003c\/li\u003e\n  \u003cli\u003eCommercial and office building electrical panels\u003c\/li\u003e\n  \u003cli\u003eFinal circuit overcurrent protection in building installations\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounted switchgear requiring overvoltage category III devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 60898-1. Part of the Eaton Moeller series xPole range of protective devices.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PL7-C25\/1, Eaton 262706, Eaton catalog 262706, Eaton model PL7-C25\/1, xPole 25A type C MCB, Eaton Moeller PL7 C25.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251472396552,"sku":"ETN262706","price":3.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/262706-pl7-c251-miniature-circuit-breaker-1p-c25a-10ka-651975.jpg?v=1735225384"},{"product_id":"262707-pl7-c32-1-miniature-circuit-breaker-1p-c32a-10ka","title":"Eaton 262707 PL7-C32\/1 MCB 1P 32 A C Curve 10kA DIN Rail","description":"\u003cp\u003eThe Eaton PL7-C32\/1 is a single-pole miniature circuit breaker from the Eaton Moeller series xPole range, providing reliable overcurrent protection in residential and commercial switchgear. With a rated current of 32 A and tripping characteristic C, it delivers a rated switching capacity of 10 kA per IEC\/EN 60898-1 at both 230 V and 400 V. Its compact single-module width fits standard DIN rail assemblies and supports additional xPole accessories.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PL7-C32\/1\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 262707\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082627072\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eSeries: Eaton Moeller xPole\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1 (single-pole)\u003c\/li\u003e\n  \u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 32 A\u003c\/li\u003e\n  \u003cli\u003eRated switching capacity (IEC\/EN 60898-1): 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit breaking capacity (Icn) at 230 V: 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit breaking capacity (Icn) at 400 V: 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage (Ue): 230 V AC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: III\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class: 3\u003c\/li\u003e\n  \u003cli\u003eFrequency rating: 50-60 Hz\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to +75 °C\u003c\/li\u003e\n  \u003cli\u003eWidth: 17.6 mm (1 modular spacing)\u003c\/li\u003e\n  \u003cli\u003eHeight: 82 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 71 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross-section (solid-core): 1-25 mm²\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross-section (multi-wired): 1-25 mm²\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation (current-dependent): 3.7 W\u003c\/li\u003e\n  \u003cli\u003eCompliances: RoHS conform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e10 kA breaking capacity at 230 V and 400 V ensures robust short-circuit protection across common supply voltages\u003c\/li\u003e\n  \u003cli\u003eCharacteristic C tripping curve handles moderate inrush currents from motors, transformers, and mixed loads\u003c\/li\u003e\n  \u003cli\u003eCompatible with additional xPole accessories for extended functionality within the same modular system\u003c\/li\u003e\n  \u003cli\u003eWide temperature range (-25 °C to +75 °C) suits demanding installation environments\u003c\/li\u003e\n  \u003cli\u003eSingle-module (17.6 mm) footprint maximises usable DIN rail space in compact enclosures\u003c\/li\u003e\n  \u003cli\u003eRoHS-compliant materials support environmental and regulatory requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential distribution boards and consumer units\u003c\/li\u003e\n  \u003cli\u003eCommercial switchgear panels and sub-distribution boards\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection for lighting, heating, and general power outlets\u003c\/li\u003e\n  \u003cli\u003eOffice and retail installation switchgear requiring characteristic C protection\u003c\/li\u003e\n  \u003cli\u003eAuxiliary circuits in industrial control cabinets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 60898-1. Part of the Eaton Moeller xPole series for residential and commercial protective devices.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PL7-C32\/1, Eaton 262707, Eaton catalog 262707, Eaton model PL7-C32\/1, Eaton xPole 32A MCB, Eaton C32 single-pole circuit breaker.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251472757000,"sku":"ETN262707","price":3.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/262707-pl7-c321-miniature-circuit-breaker-1p-c32a-10ka-521731.jpg?v=1735225384"},{"product_id":"286528-pl6-c2-1-miniature-circuit-breaker-1p-c2a-6ka","title":"Eaton 286528 PL6-C2\/1 MCB 1P 2 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Eaton PL6-C2\/1 (catalog number 286528) is a single-pole miniature circuit breaker from the Moeller series xPole PL6 range, providing overcurrent and short-circuit protection for residential and commercial switchgear. Rated at 2 A with tripping characteristic C and a breaking capacity of 6 kA to IEC\/EN 60898-1, it fits in a slim 1-module DIN rail slot of just 17.7 mm wide.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PL6-C2\/1\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 286528\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082865283\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1 (single-pole)\u003c\/li\u003e\n  \u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 2 A\u003c\/li\u003e\n  \u003cli\u003eRated switching capacity (IEC\/EN 60898-1): 6 kA\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage (Ue) max: 230 V AC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class: 3\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: III\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to +75 °C\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 17.7 mm x 73 mm x 85 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 70.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eWidth: 1 modular spacing\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section solid-core: 1-25 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section multi-wired: 1-25 mm²\u003c\/li\u003e\n  \u003cli\u003ePower dissipation: 1.4 W\u003c\/li\u003e\n  \u003cli\u003eCompliances: RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCurrent limiting class 3 provides enhanced downstream protection against high fault currents\u003c\/li\u003e\n  \u003cli\u003eWide conductor cross-section range of 1-25 mm² accepts both solid and multi-wired cables\u003c\/li\u003e\n  \u003cli\u003e1-module width (17.7 mm) conserves panel space in compact DIN rail installations\u003c\/li\u003e\n  \u003cli\u003eBroad operating temperature range from -25 °C to +75 °C suits varied installation environments\u003c\/li\u003e\n  \u003cli\u003eCompatible with additional xPole auxiliary equipment and accessories\u003c\/li\u003e\n  \u003cli\u003eRoHS-compliant construction for environmentally regulated projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal circuit protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial and light-industrial switchgear panels\u003c\/li\u003e\n  \u003cli\u003eLow-voltage consumer unit installations\u003c\/li\u003e\n  \u003cli\u003eDIN rail enclosures requiring compact single-pole overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eProtection of control and signalling circuits in building installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 60898-1. Part of the Eaton Moeller xPole PL6 series for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PL6-C2\/1, Eaton 286528, Eaton catalog 286528, Eaton model PL6-C2\/1, Eaton xPole PL6 2A MCB, Eaton Moeller PL6-C2\/1.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251475345672,"sku":"ETN286528","price":4.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/286528-pl6-c21-miniature-circuit-breaker-1p-c2a-6ka-763280.jpg?v=1735325460"},{"product_id":"286529-pl6-c4-1-miniature-circuit-breaker-1p-c4a-6ka","title":"Eaton 286529 PL6-C4\/1 MCB 1P 4 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Eaton PL6-C4\/1 is a single-pole miniature circuit breaker from the Eaton Moeller series xPole range, designed to protect circuits against overcurrent and short-circuit faults in residential and commercial installations. With a 4 A rated current, tripping characteristic C, and a 6 kA rated switching capacity to IEC\/EN 60898-1, it delivers reliable protection for general wiring and moderate inductive loads.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PL6-C4\/1\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 286529\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082865290\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1 (single-pole)\u003c\/li\u003e\n  \u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 4 A\u003c\/li\u003e\n  \u003cli\u003eRated switching capacity (IEC\/EN 60898-1): 6 kA\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage (Ue): 230 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class: 3\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: III\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n  \u003cli\u003eConductor cross section (solid-core and multi-wired): 1-25 mm²\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to +75 °C\u003c\/li\u003e\n  \u003cli\u003eWidth: 17.7 mm (1 modular spacing)\u003c\/li\u003e\n  \u003cli\u003eHeight: 73 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 85 mm (built-in depth: 70.5 mm)\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation (current-dependent): 1.4 W\u003c\/li\u003e\n  \u003cli\u003ePower loss: 1.5 W\u003c\/li\u003e\n  \u003cli\u003eCompliance: RoHS conform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCompact 1-module width of 17.7 mm maximises usable space on DIN rails in distribution boards\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class 3 minimises let-through energy during short circuits, protecting downstream devices\u003c\/li\u003e\n  \u003cli\u003eWide conductor connection range of 1-25 mm² (solid-core and multi-wired) allows flexible cable sizing\u003c\/li\u003e\n  \u003cli\u003eExtended operating temperature range of -25 °C to +75 °C suits demanding panel environments\u003c\/li\u003e\n  \u003cli\u003eCompatible with additional xPole accessories, expanding installation options without additional hardware\u003c\/li\u003e\n  \u003cli\u003eRoHS compliant materials support environmental and regulatory requirements across European markets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal circuit overcurrent protection in residential consumer units and distribution boards\u003c\/li\u003e\n  \u003cli\u003eLighting and socket circuit protection in commercial buildings and offices\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection for control circuits in light industrial switchgear panels\u003c\/li\u003e\n  \u003cli\u003eProtection of resistive loads such as heating elements and low-power appliances\u003c\/li\u003e\n  \u003cli\u003eSub-distribution panels requiring compact DIN rail MCBs with supplementary accessory support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 60898-1. Part of the Eaton Moeller series xPole range of protective devices for residential and commercial switchgear applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PL6-C4\/1, Eaton 286529, Eaton catalog 286529, Eaton model PL6-C4\/1, Eaton xPole MCB 4A curve C, Moeller PL6 4A single-pole MCB.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251475738888,"sku":"ETN286529","price":4.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/286529-pl6-c41-miniature-circuit-breaker-1p-c4a-6ka-803269.jpg?v=1735225448"},{"product_id":"286530-pl6-c6-1-miniature-circuit-breaker-1p-c6a-6ka","title":"Eaton 286530 PL6-C6\/1 MCB 1P 6 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Eaton PL6-C6\/1 is a single-pole miniature circuit breaker from the Eaton Moeller xPole PL6 series, designed for overcurrent and short-circuit protection in residential and commercial electrical installations. Rated at 6 A with a Type C tripping characteristic, it achieves a rated switching capacity of 6 kA in accordance with IEC\/EN 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PL6-C6\/1\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 286530\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082865306\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1\u003c\/li\u003e\n  \u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 6 A\u003c\/li\u003e\n  \u003cli\u003eRated switching capacity (IEC\/EN 60898-1): 6 kA\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit breaking capacity (Icn) at 230 V: 6 kA\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit breaking capacity (Icn) at 400 V: 6 kA\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage (UE): 230 V AC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (UI): 440 V\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: III\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class: 3\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to +75 °C\u003c\/li\u003e\n  \u003cli\u003eDimensions (H x W x D): 73 x 17.7 x 85 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 70.5 mm\u003c\/li\u003e\n  \u003cli\u003eWidth: 1 modular spacing\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross section (solid-core and multi-wired): 1-25 mm²\u003c\/li\u003e\n  \u003cli\u003eEquipment heat dissipation (current-dependent): 1.5 W\u003c\/li\u003e\n  \u003cli\u003ePower loss: 1.2 W\u003c\/li\u003e\n  \u003cli\u003eCompliances: RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCompact 1-module width (17.7 mm) conserves DIN rail space in tight enclosures\u003c\/li\u003e\n  \u003cli\u003e6 kA rated breaking capacity at both 230 V and 400 V ensures reliable fault clearance\u003c\/li\u003e\n  \u003cli\u003eWide ambient temperature range of -25 °C to +75 °C suits demanding installation environments\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class 3 reduces thermal and mechanical stress on downstream components\u003c\/li\u003e\n  \u003cli\u003eCompatible with additional accessories for expanded functionality\u003c\/li\u003e\n  \u003cli\u003eRoHS compliant construction meets European hazardous substance requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal circuit overcurrent protection in residential consumer units and distribution boards\u003c\/li\u003e\n  \u003cli\u003eLighting circuit protection in commercial and retail premises\u003c\/li\u003e\n  \u003cli\u003eSocket outlet circuit protection in domestic and light commercial installations\u003c\/li\u003e\n  \u003cli\u003eSmall motor and transformer loads requiring a Type C tripping characteristic\u003c\/li\u003e\n  \u003cli\u003eSwitchgear assemblies for residential and commercial building services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 60898-1. Part of the Eaton Moeller xPole switchgear range for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PL6-C6\/1, Eaton 286530, Eaton catalog 286530, Eaton model PL6-C6\/1, Eaton xPole 6 A Type C MCB, Eaton Moeller PL6 C6 1-pole MCB.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251475771656,"sku":"ETN286530","price":2.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/286530-pl6-c61-miniature-circuit-breaker-1p-c6a-6ka-928481.jpg?v=1735225452"},{"product_id":"286531-pl6-c10-1-miniature-circuit-breaker-1p-c10a-6ka","title":"Eaton 286531 PL6-C10\/1 MCB 1P 10 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Eaton PL6-C10\/1 is a 1-pole miniature circuit breaker from the Eaton Moeller series xPole PL6 range, providing overcurrent protection in residential and commercial switchgear. Rated at 10 A with a Type C tripping characteristic, it delivers a 6 kA short-circuit breaking capacity at 230 V and 400 V per IEC\/EN 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PL6-C10\/1\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 286531\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082865313\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1 (single-pole)\u003c\/li\u003e\n  \u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 10 A\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn, IEC\/EN 60898-1): 6 kA at 230 V and 400 V\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage (Ue): 230 V AC max\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class: 3\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 - 60 Hz\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: III\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 75 °C\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor: 1 - 25 mm² (solid-core and multi-wired)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 17.7 x 73 x 85 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 70.5 mm\u003c\/li\u003e\n  \u003cli\u003eWidth: 1 modular spacing\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.12 kg\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation (current-dependent): 1.5 W\u003c\/li\u003e\n  \u003cli\u003eCompliances: RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType C tripping characteristic suits circuits with moderate inrush currents in residential and commercial applications\u003c\/li\u003e\n  \u003cli\u003e6 kA breaking capacity (current limiting class 3) ensures safe fault clearance under short-circuit conditions\u003c\/li\u003e\n  \u003cli\u003eWide ambient operating range of -25 °C to 75 °C for demanding installation environments\u003c\/li\u003e\n  \u003cli\u003eSlim 1-module width (17.7 mm) conserves DIN rail space in compact distribution boards\u003c\/li\u003e\n  \u003cli\u003eCompatible with additional accessories, expanding functionality within the xPole system\u003c\/li\u003e\n  \u003cli\u003eRoHS compliant construction meets environmental requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal circuit protection in residential consumer units and distribution boards\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection in commercial office and retail switchgear panels\u003c\/li\u003e\n  \u003cli\u003eDIN rail installations in light industrial control cabinets\u003c\/li\u003e\n  \u003cli\u003eProtection of general lighting and socket outlet circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 60898-1. Part of the Eaton Moeller series xPole PL6 miniature circuit breaker family.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PL6-C10\/1, Eaton 286531, Eaton catalog 286531, Eaton model PL6-C10\/1, xPole 10A Type C single-pole MCB.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251476033800,"sku":"ETN286531","price":2.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/286531-pl6-c101-miniature-circuit-breaker-1p-c10a-6ka-648688.jpg?v=1735225448"}],"url":"https:\/\/gabbyelectric.com\/en-ca\/collections\/1-pole-mcb.oembed?page=9","provider":"Gabby Electric","version":"1.0","type":"link"}