{"product_id":"schneider-gv5p220h-tesys-gv5-motor-circuit-breaker-3p-220a-70ka","title":"Schneider GV5P220H TeSys GV5 Motor Circuit Breaker 3P 220A 70kA","description":"\u003cp\u003eThe Schneider Electric GV5P220H is a TeSys GV5 3-pole motor circuit breaker rated 220 A at 65 °C, with a breaking capacity of 70 kA Icu at 400\/415 V AC. It suits motors of 90 to 110 kW at 400\/415 V, is operated by a direct rotary handle, and is suitable for isolation to EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: GV5P220H\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: 3606489915438\u003c\/li\u003e\n  \u003cli\u003eRange: TeSys GV5\u003c\/li\u003e\n  \u003cli\u003eProduct type: Motor circuit breaker\u003c\/li\u003e\n  \u003cli\u003eDevice application: Motor protection\u003c\/li\u003e\n  \u003cli\u003ePoles description: 3P\u003c\/li\u003e\n  \u003cli\u003e[In] rated current: 220 A at 65 °C\u003c\/li\u003e\n  \u003cli\u003eMotor power: 90...110 kW at 400\/415 V AC 50\/60 Hz; 110 kW at 500 V AC 50\/60 Hz; 110...132 kW at 660\/690 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 70 kA Icu at 400\/415 V AC 50\/60 Hz conforming to IEC 60947-2; 50 kA Icu at 500 V AC 50\/60 Hz conforming to IEC 60947-2; 10 kA Icu at 660\/690 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping current: 3300 A\u003c\/li\u003e\n  \u003cli\u003eRated conditional short-circuit current: 60 kA at 440 V\u003c\/li\u003e\n  \u003cli\u003e[Ue] rated operational voltage: 690 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003e[Ui] rated insulation voltage: 800 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003e[Uimp] rated impulse withstand voltage: 8 kV\u003c\/li\u003e\n  \u003cli\u003eUtilisation category: Category A conforming to IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eControl type: Direct rotary handle\u003c\/li\u003e\n  \u003cli\u003ePhase failure sensitivity: Yes conforming to IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eSuitability for isolation: Yes conforming to EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eConnections: Bars; Lugs\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 15 N.m M8 screw type\u003c\/li\u003e\n  \u003cli\u003ePower dissipation per pole: 17.6 W\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 5000 cycles for AC-3 at 415 V opening; 5000 cycles for AC-3 at 415 V closing\u003c\/li\u003e\n  \u003cli\u003eHeight: 161 mm\u003c\/li\u003e\n  \u003cli\u003eWidth: 105 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 155 mm\u003c\/li\u003e\n  \u003cli\u003eNet weight: 2.6 kg\u003c\/li\u003e\n  \u003cli\u003eColour: Anthracite (RAL 7016)\u003c\/li\u003e\n  \u003cli\u003eIP degree of protection: IP40 conforming to IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70 °C\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-1, EN\/IEC 60947-2, EN\/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":58920157675784,"sku":"SCHGV5P220H","price":341.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/SCHGV5P220H.png?v=1790687870","url":"https:\/\/gabbyelectric.com\/cs\/products\/schneider-gv5p220h-tesys-gv5-motor-circuit-breaker-3p-220a-70ka","provider":"Gabby Electric","version":"1.0","type":"link"}