{"product_id":"schneider-a9f84406-acti9-ic60h-mcb-4p-c6a-10ka-din-rail","title":"Schneider A9F84406 Acti9 iC60H MCB 4P C6A 10kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9F84406 is an Acti9 iC60H miniature circuit breaker, 4-pole, 6 A, C curve. It provides overload and short-circuit protection with a rated breaking capacity of 10000 A (Icn) to EN\/IEC 60898-1 and up to 15 kA (Icu) at 380-415 V AC to EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F84406\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eRange: Acti9\u003c\/li\u003e\n  \u003cli\u003eProduct name: Acti9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60H\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit-breaker\u003c\/li\u003e\n  \u003cli\u003ePoles: 4P (4 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 6 A\u003c\/li\u003e\n  \u003cli\u003eCurve code: C\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 8 x In +\/- 20 %\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage (Ue): 12...133 V AC, 220...240 V AC, 380...415 V AC, 440 V AC, \u0026lt;= 250 V DC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 42 kA Icu at 12...133 V AC 50\/60 Hz conforming to EN\/IEC 60947-2; 30 kA Icu at 220...240 V AC 50\/60 Hz conforming to EN\/IEC 60947-2; 15 kA Icu at 380...415 V AC 50\/60 Hz conforming to EN\/IEC 60947-2; 10 kA Icu at 440 V AC 50\/60 Hz conforming to EN\/IEC 60947-2; 15 kA Icu at \u0026lt;= 250 V DC conforming to EN\/IEC 60947-2; 10000 A Icn at 400 V AC 50\/60 Hz conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz conforming to EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV conforming to EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eUtilisation category: Category A conforming to EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eSuitability for isolation: Yes conforming to EN\/IEC 60947-2 and EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on on 35 mm DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth in 9 mm pitches: 8\u003c\/li\u003e\n  \u003cli\u003eDimensions (HxWxD): 85 mm x 72 mm x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eProduct weight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eColour: White\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eConnections: Single terminal (top or bottom) , for 1 cable(s) , 1…25 mm², rigid, copper\u003c\/li\u003e\n  \u003cli\u003eWire stripping length: 14 mm for top or bottom connection\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m top or bottom\u003c\/li\u003e\n  \u003cli\u003eIP degree of protection: IP20 conforming to IEC 60529\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-2, EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve magnetic trip at 8 x In +\/- 20 % for inductive loads such as motors and transformers\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation to both EN\/IEC 60947-2 and EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible for fast distribution board wiring\u003c\/li\u003e\n  \u003cli\u003eClip-on mounting to 35 mm DIN rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eOverload and short-circuit protection of final circuits in distribution boards\u003c\/li\u003e\n  \u003cli\u003eThree-phase plus neutral circuits at 380-415 V AC\u003c\/li\u003e\n  \u003cli\u003eIndustrial and commercial installations requiring a 10 kA breaking capacity\u003c\/li\u003e\n  \u003cli\u003eCircuits with inductive inrush that would nuisance-trip a B curve device\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConforms to EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider Electric A9F84406.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":58361175539976,"sku":"SCHA9F84406","price":29.61,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/SCHA9F84406.png?v=1785881349","url":"https:\/\/gabbyelectric.com\/cs\/products\/schneider-a9f84406-acti9-ic60h-mcb-4p-c6a-10ka-din-rail","provider":"Gabby Electric","version":"1.0","type":"link"}