{"product_id":"r9ra1263-schneider-electric-residual-current-circuit-breaker-rccb-resi9-xe-id-2p-63a-30ma-a-type","title":"Schneider R9RA1263 Residual Current Circuit Breaker (RCCB), Resi9 XE ID, 2P 63A","description":"\u003cp\u003eThe Schneider Electric R9RA1263 is a 2-pole residual current circuit breaker (RCCB) from the Resi9 XE ID range, rated at 63 A with 30 mA earth-leakage sensitivity. Designed for Type A protection, it provides instantaneous tripping against both AC and pulsating DC residual currents, making it suitable for modern electrical installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: R9RA1263\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Resi9 XE ID\u003c\/li\u003e\n  \u003cli\u003eProduct type: Residual current circuit breaker (RCCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNeutral position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 63 A at 30 °C (conforming to EN\/IEC 61008)\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage [Ue]: 230 V AC 50 Hz (-15...+10%)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eEarth-leakage sensitivity: 30 mA (conforming to EN\/IEC 61008)\u003c\/li\u003e\n  \u003cli\u003eEarth-leakage protection class: Type A\u003c\/li\u003e\n  \u003cli\u003eEarth-leakage protection time delay: Instantaneous\u003c\/li\u003e\n  \u003cli\u003eRated breaking and making capacity: Im 630 A (conforming to EN 61008-2-1)\u003c\/li\u003e\n  \u003cli\u003eRated conditional short-circuit current: Inc 3000 A with 100 A gG (Resi9 MCB)\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 36 mm (4 x 9 mm pitches)\u003c\/li\u003e\n  \u003cli\u003eHeight: 83 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 68 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 185 g\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20, IP40 (in modular enclosure)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...40 °C\u003c\/li\u003e\n  \u003cli\u003eConnection type: Tunnel type terminals - 1...25 mm² rigid \/ 1...16 mm² flexible \/ 1...16 mm² flexible with ferrule\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eControl type: Toggle\u003c\/li\u003e\n  \u003cli\u003eColour: White (RAL 9003)\u003c\/li\u003e\n  \u003cli\u003eMechanical \/ electrical durability: 2000 cycles\u003c\/li\u003e\n  \u003cli\u003eCertifications: CE, CEBEC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType A earth-leakage protection detects both sinusoidal AC and pulsating DC residual currents for enhanced safety in modern installations.\u003c\/li\u003e\n  \u003cli\u003eInstantaneous tripping response minimises exposure time during earth-leakage faults.\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and ON\/OFF local signalling provide clear visual status at a glance.\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting simplifies installation and panel assembly.\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25...40 °C ensures reliable performance across varied environments.\u003c\/li\u003e\n  \u003cli\u003eElectromagnetic impulse withstand of 3000 A (8\/20 µs) provides resilience against transient surge events.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential final distribution boards requiring earth-leakage protection for circuits up to 63 A.\u003c\/li\u003e\n  \u003cli\u003eCommercial electrical panels where Type A protection is required for electronic and mixed loads.\u003c\/li\u003e\n  \u003cli\u003eModular enclosure installations demanding IP40 protection in conjunction with an enclosure.\u003c\/li\u003e\n  \u003cli\u003eRetrofit or upgrade projects replacing existing 2P RCCBs on standard DIN rail systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 61008-1 and EN\/IEC 61008-2-1. Part of the Schneider Electric Resi9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider R9RA1263, Schneider Electric R9RA1263, Schneider 2P 63A 30mA Type A RCCB, Resi9 XE ID residual current device.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53107741982984,"sku":"SCHR9RA1263","price":110.12,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/r9ra1263-schneider-electric-residual-current-circuit-breaker-rccb-resi9-xe-id-2p-63a-30ma-a-type-1136151.png?v=1768101371","url":"https:\/\/gabbyelectric.com\/cs\/products\/r9ra1263-schneider-electric-residual-current-circuit-breaker-rccb-resi9-xe-id-2p-63a-30ma-a-type","provider":"Gabby Electric","version":"1.0","type":"link"}