{"product_id":"a9f83110-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-1p-10a-b-curve-10ka","title":"Schneider A9F83110 Miniature Circuit Breaker (MCB), Acti9 iC60H, 1P 10A B curve","description":"\u003cp\u003eSchneider Electric A9F83110 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60H series, rated at 10A with a B tripping curve. It provides thermal-magnetic overcurrent protection for both AC and DC networks, with a high breaking capacity of 10,000A (Icn) at 230V AC per IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F83110\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60H\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 10A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 10,000A at 230V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUltimate breaking capacity (Icu): 15 kA at 220-240V AC; 42 kA at 12-60V AC; 15 kA at 72V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7,500A (75%) at 230V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60898-1, EN 60898-1, IEC 60947-2, EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003eTrip indicator for local fault signalling\u003c\/li\u003e\n  \u003cli\u003eB curve for sensitive loads requiring earlier tripping at lower overcurrent multiples\u003c\/li\u003e\n  \u003cli\u003ePollution degree 3 rating suitable for industrial environments\u003c\/li\u003e\n  \u003cli\u003eTropicalization class 2 per IEC 60068-1 for humid environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial installations\u003c\/li\u003e\n  \u003cli\u003eProtection of sensitive loads such as lighting circuits and measuring equipment\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery systems\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring AC and DC overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eDistribution of electrical energy in low-voltage switchgear assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F83110, Schneider Electric A9F83110, Acti9 iC60H 1P 10A B curve MCB, Schneider 10A B-curve miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53477171888392,"sku":"SCHA9F83110","price":4.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/schneider-a9f83110-miniature-circuit-breaker-mcb-acti9-ic60h-1p-10a-b-curve-4032024.jpg?v=1779036894","url":"https:\/\/gabbyelectric.com\/cs\/products\/a9f83110-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-1p-10a-b-curve-10ka","provider":"Gabby Electric","version":"1.0","type":"link"}