{"title":"Thermal Overload Relays","description":"\u003cp\u003eProtect your motors and electrical systems with our reliable \u003cstrong\u003eThermal Overload Relays\u003c\/strong\u003e. These devices are designed to prevent motor damage by detecting and interrupting overcurrent conditions caused by overloads or phase failures.\u003c\/p\u003e\n\u003cp\u003eSourced from globally trusted brands, our thermal overload relays offer precise performance, durability, and compliance with international safety standards. Ideal for industrial and commercial applications, they ensure the safety and longevity of your motors and machinery.\u003c\/p\u003e\n\u003cp\u003eBrowse our in-stock selection and enjoy fast, worldwide shipping to keep your systems protected and running efficiently.\u003c\/p\u003e","products":[{"product_id":"lr2k0301-differential-thermal-overload-relay-tesys-k-0-11-0-16a-class-10a","title":"Schneider LR2K0301 TeSys K Overload Relay 0.11-0.16A Class 10A Direct Mount","description":"\u003cp\u003eThe Schneider Electric LR2K0301 is a TeSys K differential thermal overload relay designed for motor protection. It offers an adjustable thermal overload setting of 0.11 to 0.16 A with tripping class 10A per IEC 60947-4-1, and is compatible with TeSys K contactors including LC1K, LP4K, LP1K, and LC7K, operating on both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LR2K0301\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys K (TeSys LRK)\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eThermal overload adjustment: 0.11 - 0.16 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V per IEC 60947 \/ BS 4941; 750 V per VDE 0110 group C\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003ePermissible thermal current [Ith]: 6 A (signal circuit)\u003c\/li\u003e\n  \u003cli\u003eDissipation power per pole: 2 W\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: Yes, per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eMounting: Under contactor; or on panel\/rail with accessories\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminal blocks, 0.34 - 4 mm²\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.3 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 45 x 58 x 65 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.145 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP2x per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20 to 55 °C (no characteristic change); storage: -40 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947, VDE 0660, NF C 63-650, BS 4941\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL, CSA, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhase loss sensitivity for motor protection per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eYellow trip indicator for local fault signaling\u003c\/li\u003e\n  \u003cli\u003eSelectable manual or automatic reset via front-mounted selector switch\u003c\/li\u003e\n  \u003cli\u003eRed test button for trip function testing; blue button for stop and manual reset\u003c\/li\u003e\n  \u003cli\u003eDirect mount under TeSys K contactors for compact panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor protection in industrial control and automation panels\u003c\/li\u003e\n  \u003cli\u003eCompact motor starter assemblies with TeSys K contactors\u003c\/li\u003e\n  \u003cli\u003eLow-current motor applications in machine building and OEM equipment\u003c\/li\u003e\n  \u003cli\u003eAC and DC motor control systems requiring thermal overload protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-4-1, VDE 0660, NF C 63-650, and BS 4941. Part of the Schneider Electric TeSys K range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LR2K0301, Schneider Electric LR2K0301, TeSys K thermal relay, motor overload relay.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065384661256,"sku":"SCHLR2K0301","price":23.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lr2k0301-differential-thermal-overload-relay-tesys-k-011016a-class-10a-303199.jpg?v=1735247201"},{"product_id":"lr2k0302-differential-thermal-overload-relay-tesys-k-0-16-0-23a-class-10a","title":"Schneider LR2K0302 TeSys K Overload Relay 0.16-0.23A Class 10A Direct Mount","description":"\u003cp\u003eThe Schneider Electric LR2K0302 is a TeSys K differential thermal overload relay for motor protection in AC and DC networks. With an adjustable current range of 0.16 to 0.23 A and Class 10A tripping per IEC 60947-4-1, it protects small motors from overload damage. Designed to mount directly below TeSys K contactors (LC1K, LP4K, LP1K, LC7K) for compact motor starter assemblies.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LR2K0302\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys K (TeSys LRK)\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eThermal overload adjustment: 0.16...0.23 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V per IEC 60947 \/ BS 4941; 750 V per VDE 0110 group C; 600 V per CSA C22.2 No 14\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003ePermissible thermal current [Ith]: 6 A (control circuit)\u003c\/li\u003e\n  \u003cli\u003eAssociated fuse: 6 A gG (control circuit)\u003c\/li\u003e\n  \u003cli\u003ePower dissipation per pole: 2 W\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminal blocks, 1.5...4 mm² solid \/ 0.75...4 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.3 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 45 x 58 x 65 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.145 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP2x per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...55°C without characteristic change per IEC 60947\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70°C\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947, VDE 0660, NF C 63-650, BS 4941\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL, CSA, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhase loss sensitivity per IEC 60947-4-1 for enhanced motor protection\u003c\/li\u003e\n  \u003cli\u003eYellow trip indicator for clear local fault signalling\u003c\/li\u003e\n  \u003cli\u003eSelectable manual or automatic reset via front-panel selector switch\u003c\/li\u003e\n  \u003cli\u003eRed test button to verify trip function without disconnecting the circuit\u003c\/li\u003e\n  \u003cli\u003eDirect mounting below TeSys K contactors for space-saving panel design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor protection in industrial automation and control panels\u003c\/li\u003e\n  \u003cli\u003eDirect-on-line motor starters assembled with TeSys K contactors\u003c\/li\u003e\n  \u003cli\u003eSmall pump and fan motor protection\u003c\/li\u003e\n  \u003cli\u003eLow-current motor circuits in AC and DC installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-4-1, VDE 0660, NF C 63-650, and BS 4941. Part of the Schneider Electric TeSys K range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LR2K0302, Schneider Electric LR2K0302, TeSys K thermal overload relay, motor protection relay.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065384759560,"sku":"SCHLR2K0302","price":22.12,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lr2k0302-differential-thermal-overload-relay-tesys-k-016023a-class-10a-160439.jpg?v=1735247200"},{"product_id":"lr2k0303-differential-thermal-overload-relay-tesys-k-0-23-0-36a-class-10a","title":"Schneider LR2K0303 TeSys K Overload Relay 0.23-0.36A Class 10A Direct Mount","description":"\u003cp\u003eThe Schneider Electric LR2K0303 is a TeSys K differential thermal overload relay for motor protection, with a thermal overload setting of 0.23 to 0.36 A and Class 10A tripping characteristic per IEC 60947-4-1. Compatible with LC1K, LC7K, LP1K, and LP4K contactors, it mounts directly below the contactor for compact panel assembly.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LR2K0303\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys K\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 0.23...0.36 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A (IEC 60947-4-1)\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: up to 400 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 690 V (IEC 60947), 600 V (CSA)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: Yes (IEC 60947-4-1)\u003c\/li\u003e\n  \u003cli\u003eDissipation power per pole: 2 W\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminal blocks, 1.5...4 mm² solid \/ 0.75...4 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.3 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 45 x 58 x 65 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.145 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP2x (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...55°C without characteristic change (IEC 60947)\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70°C\u003c\/li\u003e\n  \u003cli\u003eOperating altitude: up to 2000 m without characteristic change\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL, CSA, UKCA\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947, VDE 0660, BS 4941, NF C 63-650\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect mounting below TeSys K contactors eliminates additional wiring for compact panel assemblies\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity per IEC 60947-4-1 prevents motor damage from single-phase running conditions\u003c\/li\u003e\n  \u003cli\u003eYellow trip indicator provides clear local fault signaling at the device\u003c\/li\u003e\n  \u003cli\u003eRed test button verifies trip function; blue button enables stop and manual reset\u003c\/li\u003e\n  \u003cli\u003eSelector switch allows choice between manual or automatic reset mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor overload protection in industrial automation control panels\u003c\/li\u003e\n  \u003cli\u003eSmall motor protection paired with TeSys K contactors in machine tool circuits\u003c\/li\u003e\n  \u003cli\u003ePump and HVAC motor protection in building services installations\u003c\/li\u003e\n  \u003cli\u003eMotor control assemblies on production lines and conveyor systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-4-1, VDE 0660, BS 4941, and NF C 63-650. Part of the Schneider Electric TeSys K range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LR2K0303, Schneider Electric LR2K0303, TeSys K overload relay, thermal overload relay 0.23-0.36A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065384923400,"sku":"SCHLR2K0303","price":22.12,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lr2k0303-differential-thermal-overload-relay-tesys-k-023036a-class-10a-997569.jpg?v=1735247199"},{"product_id":"lr2k0304-differential-thermal-overload-relay-tesys-k-0-36-0-54a-class-10a","title":"Schneider LR2K0304 TeSys K Overload Relay 0.36-0.54A Class 10A Direct Mount","description":"\u003cp\u003eThe Schneider Electric LR2K0304 is a TeSys K series differential thermal overload relay designed for motor protection. It provides adjustable thermal overload protection from 0.36 to 0.54 A with trip class 10A per IEC 60947-4-1, and is compatible with LP1K, LC1K, LC7K, and LP4K contactors for AC and DC network applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LR2K0304\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys K\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eApplication: Motor protection\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 0.36...0.54 A\u003c\/li\u003e\n  \u003cli\u003eTrip class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 690 V (IEC 60947), 750 V (VDE 0110 group C)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003ePermissible thermal current (ith): 6 A for control circuit\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: Yes per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor; on plate or rail with accessory\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminal blocks, 0.34...4 mm² solid or flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.3 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 45 x 58 x 65 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.145 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP2x per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...55 °C (no change in characteristics)\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70 °C\u003c\/li\u003e\n  \u003cli\u003eOperating altitude: 2000 m without change in characteristics\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947, NF C 63-650, VDE 0660, BS 4941\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL, CSA, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhase loss detection per IEC 60947-4-1 for comprehensive motor protection\u003c\/li\u003e\n  \u003cli\u003eYellow trip indicator provides clear local fault signaling\u003c\/li\u003e\n  \u003cli\u003eRed test button allows verification of the trip function without disconnecting load\u003c\/li\u003e\n  \u003cli\u003eBlue button for motor stop and manual reset; selector switch for manual or automatic reset mode\u003c\/li\u003e\n  \u003cli\u003eDirect mounting below TeSys K contactors simplifies panel assembly and reduces wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor protection in industrial control and automation panels\u003c\/li\u003e\n  \u003cli\u003eDirect-on-line starter assemblies with TeSys K series contactors\u003c\/li\u003e\n  \u003cli\u003eAC and DC motor drive protection in machine control panels\u003c\/li\u003e\n  \u003cli\u003eLow-power motor control applications requiring Class 10A trip protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947, NF C 63-650, VDE 0660, and BS 4941. Part of the Schneider Electric TeSys K range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LR2K0304, Schneider Electric LR2K0304, TeSys K overload relay, thermal overload relay 0.36-0.54A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065384988936,"sku":"SCHLR2K0304","price":22.12,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lr2k0304-differential-thermal-overload-relay-tesys-k-036054a-class-10a-198791.jpg?v=1735247200"},{"product_id":"lr2k0305-differential-thermal-overload-relay-tesys-k-0-54-0-8a-class-10a","title":"Schneider LR2K0305 TeSys K Overload Relay 0.54-0.8A Class 10A Direct Mount","description":"\u003cp\u003eThe Schneider Electric LR2K0305 is a TeSys K differential thermal overload relay designed for motor protection, with a thermal overload setting range of 0.54 to 0.8 A and Class 10A trip characteristics per IEC 60947-4-1. It mounts directly below TeSys K contactors (LC1K, LP4K, LP1K, LC7K) and is suitable for both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LR2K0305\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys K (TeSys LRK)\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eApplication: Motor protection\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 0.54...0.8 A\u003c\/li\u003e\n  \u003cli\u003eTrip class: Class 10A (IEC 60947-4-1)\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 690 V (IEC 60947); 750 V (VDE 0110 group C); 600 V (CSA C22.2 No 14)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003ePermissible thermal current (control circuit): 6 A\u003c\/li\u003e\n  \u003cli\u003eDissipation power per pole: 2 W\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: Yes (IEC 60947-4-1)\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor; panel or DIN rail with accessories\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminals, 1.5...4 mm² solid \/ 0.75...4 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.3 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 45 x 58 x 65 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.145 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP2x (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...55 °C without characteristic change (IEC 60947)\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70 °C\u003c\/li\u003e\n  \u003cli\u003eOperating altitude: up to 2000 m without characteristic change\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947, NF C 63-650, VDE 0660, BS 4941\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL, CSA, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhase loss sensitivity provides enhanced motor protection per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eYellow trip indicator enables clear local signaling of overload events\u003c\/li\u003e\n  \u003cli\u003eRed test button for trip function testing, blue button for stop and manual reset, plus manual\/automatic reset selector\u003c\/li\u003e\n  \u003cli\u003eDirect mounting below TeSys K contactors enables compact motor starter assemblies\u003c\/li\u003e\n  \u003cli\u003eWide network frequency tolerance up to 400 Hz for demanding industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor protection in industrial control panels and automation systems\u003c\/li\u003e\n  \u003cli\u003eCompact direct-on-line motor starter assemblies with TeSys K contactors\u003c\/li\u003e\n  \u003cli\u003eAC and DC motor protection in manufacturing and process equipment\u003c\/li\u003e\n  \u003cli\u003ePanel-mounted or DIN rail control cabinet installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-4-1, NF C 63-650, VDE 0660, and BS 4941. Part of the Schneider Electric TeSys K range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LR2K0305, Schneider Electric LR2K0305, TeSys K thermal overload relay, motor protection relay.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065385021704,"sku":"SCHLR2K0305","price":24.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lr2k0305-differential-thermal-overload-relay-tesys-k-05408a-class-10a-828754.jpg?v=1735247200"},{"product_id":"lr2k0306-differential-thermal-overload-relay-tesys-k-0-8-1-2a-class-10a","title":"Schneider LR2K0306 TeSys K Overload Relay 0.8-1.2A Class 10A Direct Mount","description":"\u003cp\u003eThe Schneider Electric LR2K0306 is a TeSys K differential thermal overload relay designed for motor protection, with an adjustable current setting range of 0.8 to 1.2 A and Class 10A trip classification per IEC 60947-4-1. It mounts directly below LC1K, LC7K, LP4K, and LP1K contactors, delivering integrated overload protection in compact motor starter assemblies on both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LR2K0306\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys K (TeSys LRK)\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eRelay function: Motor protection\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 0.8...1.2 A\u003c\/li\u003e\n  \u003cli\u003eTrip class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 690 V (IEC 60947 \/ BS 4941), 750 V (VDE 0110 group C), 600 V (CSA C22.2 No 14)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eThermal current - signal circuit: 6 A\u003c\/li\u003e\n  \u003cli\u003eSignal circuit voltage: 690 V AC (AC-15), 250 V DC (DC-13)\u003c\/li\u003e\n  \u003cli\u003ePower dissipation per pole: 2 W\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: Yes (IEC 60947-4-1)\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: up to 400 Hz\u003c\/li\u003e\n  \u003cli\u003eConnection type: Screw terminal blocks, 1.5...4 mm² solid \/ 0.75...4 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.3 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 45 x 58 x 65 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.145 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP2x (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...55 °C without characteristic change (IEC 60947)\u003c\/li\u003e\n  \u003cli\u003eOperating altitude: up to 2000 m without characteristic change\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL, CSA, UKCA\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947, NF C 63-650, BS 4941, VDE 0660\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhase loss sensitivity detects single-phasing conditions, protecting motors from overheating and damage\u003c\/li\u003e\n  \u003cli\u003eYellow trip indicator gives clear local visual signaling when the relay has operated\u003c\/li\u003e\n  \u003cli\u003eRed test button allows functional verification of the trip mechanism without disconnecting the circuit\u003c\/li\u003e\n  \u003cli\u003eBlue stop button and front selector switch enable either manual or automatic reset after tripping\u003c\/li\u003e\n  \u003cli\u003eDirect under-contactor mounting for LC1K, LC7K, LP4K, and LP1K reduces panel wiring and footprint\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor overload protection in industrial control panels and machine tools\u003c\/li\u003e\n  \u003cli\u003eDirect-on-line and reversing starter assemblies using TeSys K contactors\u003c\/li\u003e\n  \u003cli\u003ePump, fan, and compressor protection in building services installations\u003c\/li\u003e\n  \u003cli\u003eCompact OEM motor starters requiring contactor-mounted thermal protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-4-1, NF C 63-650, BS 4941, and VDE 0660. Part of the Schneider Electric TeSys K range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LR2K0306, Schneider Electric LR2K0306, TeSys K thermal overload relay, motor overload relay 1.2A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065385120008,"sku":"SCHLR2K0306","price":22.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lr2k0306-differential-thermal-overload-relay-tesys-k-0812a-class-10a-158539.jpg?v=1735247200"},{"product_id":"lr2k0307-differential-thermal-overload-relay-tesys-k-1-2-1-8a-class-10a","title":"Schneider LR2K0307 TeSys K Overload Relay 1.2-1.8A Class 10A Direct Mount","description":"\u003cp\u003eThe Schneider Electric LR2K0307 is a TeSys K differential thermal overload relay designed for motor protection, with an adjustable thermal overload range of 1.2 to 1.8 A and Class 10A tripping characteristic per IEC 60947-4-1. It is compatible with LC1K, LP1K, LP4K, and LC7K contactors and mounts directly below the contactor for compact motor starter assemblies on AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LR2K0307\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys K (TeSys LRK)\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eRelay application: Motor protection\u003c\/li\u003e\n  \u003cli\u003eThermal overload adjustment: 1.2-1.8 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: up to 400 Hz\u003c\/li\u003e\n  \u003cli\u003eCompatible contactors: LC1K, LP1K, LP4K, LC7K\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V (IEC 60947 \/ BS 4941), 750 V (VDE 0110 group C), 600 V (CSA C22.2 No 14)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contact: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eThermal current [Ith]: 6 A (signal circuit)\u003c\/li\u003e\n  \u003cli\u003eDissipation power per pole: 2 W\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor; panel or DIN rail mounting with accessories\u003c\/li\u003e\n  \u003cli\u003eConnection type: Screw terminal blocks, 1.5-4 mm² (solid), 0.75-4 mm² (flexible)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.3 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 45 x 58 x 65 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.145 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP2x per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20 to 55°C (without change of characteristics) per IEC 60947\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 70°C\u003c\/li\u003e\n  \u003cli\u003eOperating altitude: up to 2000 m without change of characteristics\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947, NF C 63-650, VDE 0660, BS 4941\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL, CSA, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhase loss sensitivity for protection against single-phasing per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eYellow trip indicator lamp for rapid local fault identification\u003c\/li\u003e\n  \u003cli\u003eRed test button allows trip function verification without load disconnection\u003c\/li\u003e\n  \u003cli\u003eBlue stop button with manual reset; selector switch for manual or automatic reset mode\u003c\/li\u003e\n  \u003cli\u003eWide conductor compatibility - accepts solid and flexible cables from 0.75 to 4 mm²\u003c\/li\u003e\n  \u003cli\u003eFlame resistance rated V1 per UL 94 and fire resistance to 850°C per IEC 60695-2-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor protection in industrial motor control centers and control panels\u003c\/li\u003e\n  \u003cli\u003eDirect mounting on TeSys K contactor assemblies for compact starters\u003c\/li\u003e\n  \u003cli\u003ePump, fan, and conveyor motor circuits requiring overload and phase-loss protection\u003c\/li\u003e\n  \u003cli\u003eHVAC and building automation motor control applications\u003c\/li\u003e\n  \u003cli\u003eLight industrial and commercial motor starter combinations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947, NF C 63-650, VDE 0660, and BS 4941. Part of the Schneider Electric TeSys K range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LR2K0307, Schneider Electric LR2K0307, TeSys K thermal relay 1.8A, motor overload relay LR2K0307.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065385152776,"sku":"SCHLR2K0307","price":22.12,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lr2k0307-differential-thermal-overload-relay-tesys-k-1218a-class-10a-930974.jpg?v=1735247200"},{"product_id":"lr2k0308-differential-thermal-overload-relay-tesys-k-1-8-2-6a-class-10a","title":"Schneider LR2K0308 TeSys K Overload Relay 1.8-2.6A Class 10A Direct Mount","description":"\u003cp\u003eThe Schneider Electric LR2K0308 is a TeSys K differential thermal overload relay designed for motor protection. It provides thermal overload protection with an adjustable current setting of 1.8 to 2.6 A and tripping class 10A in accordance with IEC 60947-4-1. The relay includes built-in phase loss sensitivity and mounts directly below TeSys K contactors for compact motor starter assemblies.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LR2K0308\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys K (TeSys LRK)\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eRelay application: Motor protection\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 1.8...2.6 A\u003c\/li\u003e\n  \u003cli\u003eTrip class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: up to 400 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V (IEC 60947), 750 V (VDE 0110 group C), 600 V (CSA)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003ePermitted thermal current [Ith]: 6 A for control circuit\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage [Ue]: up to 690 V AC (AC-15), 250 V DC (DC-13) for control circuit\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contact composition: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003ePower dissipation per pole: 2 W\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: Yes, per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eCompatible products: LP4K, LC1K, LC7K, LP1K\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminals, 1.5...4 mm² solid or 0.75...4 mm² flexible conductors\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.3 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 45 x 58 x 65 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.145 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP2x per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...55°C (no change in characteristics) per IEC 60947\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70°C\u003c\/li\u003e\n  \u003cli\u003eOperating altitude: up to 2000 m without change in characteristics\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL, CSA, UKCA\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947, BS 4941, VDE 0660, NF C 63-650\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhase loss sensitivity detects single-phasing conditions to prevent motor damage\u003c\/li\u003e\n  \u003cli\u003eYellow trip indicator provides immediate local visual fault signaling\u003c\/li\u003e\n  \u003cli\u003eSelector switch allows choice between manual or automatic reset after a trip\u003c\/li\u003e\n  \u003cli\u003eRed test button enables functional verification of the trip mechanism during commissioning\u003c\/li\u003e\n  \u003cli\u003eDirect mounting below TeSys K contactors simplifies panel wiring and saves space\u003c\/li\u003e\n  \u003cli\u003eSuitable for rail, panel, or contactor mounting with optional accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor starter assemblies using TeSys K contactors (LP4K, LC1K, LC7K, LP1K)\u003c\/li\u003e\n  \u003cli\u003eOverload protection for small three-phase motors in industrial control panels\u003c\/li\u003e\n  \u003cli\u003ePump and compressor motor protection in building services installations\u003c\/li\u003e\n  \u003cli\u003eConveyor and handling equipment drive protection\u003c\/li\u003e\n  \u003cli\u003eCompact motor control centres requiring direct-mount thermal protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-4-1, BS 4941, VDE 0660, and NF C 63-650. Part of the Schneider Electric TeSys K range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LR2K0308, Schneider Electric LR2K0308, TeSys K thermal overload relay, motor protection relay 2.6A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065385185544,"sku":"SCHLR2K0308","price":22.12,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lr2k0308-differential-thermal-overload-relay-tesys-k-1826a-class-10a-558592.jpg?v=1735247199"},{"product_id":"lr2k0310-differential-thermal-overload-relay-tesys-k-2-6-3-7a-class-10a","title":"Schneider LR2K0310 TeSys K Overload Relay 2.6-3.7A Class 10A Direct Mount","description":"\u003cp\u003eThe Schneider Electric LR2K0310 is a TeSys K differential thermal overload relay for motor protection, with a current setting range of 2.6 to 3.7 A and Class 10A tripping per IEC 60947-4-1. It mounts directly below TeSys K contactors (LC1K, LC7K, LP1K, LP4K) and operates on both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LR2K0310\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys K (TeSys LRK)\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eRelay use: Motor protection\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 2.6...3.7 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V per IEC 60947; 750 V per VDE 0110 group C; 600 V per CSA C22.2 No 14\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eAllowable thermal current [Ith]: 6 A (signal circuit)\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: Yes, per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor; panel or DIN rail with separate accessories\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminal blocks, 1.5...4 mm² solid, 0.75...4 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.3 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 45 x 58 x 65 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.145 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP2x per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...55°C (without characteristic change) per IEC 60947\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70°C\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947, VDE 0660, BS 4941, NF C 63-650\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL, CSA, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDifferential thermal trip mechanism protects motors reliably across AC and DC networks up to 400 Hz\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity detects single-phase conditions per IEC 60947-4-1, preventing motor damage\u003c\/li\u003e\n  \u003cli\u003eSelectable manual or automatic reset via front-mounted selector switch for flexible operation\u003c\/li\u003e\n  \u003cli\u003eYellow trip indicator provides clear local fault signaling at a glance\u003c\/li\u003e\n  \u003cli\u003eDirect-mount design below TeSys K contactors enables compact, wiring-efficient panel assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor overload protection in motor control centers and direct-on-line starter assemblies\u003c\/li\u003e\n  \u003cli\u003eReversing starter panels for industrial machinery and conveyor drives\u003c\/li\u003e\n  \u003cli\u003ePump and fan motor protection in HVAC and building services installations\u003c\/li\u003e\n  \u003cli\u003eCompressor and mixer drive protection in manufacturing and process plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947, VDE 0660, BS 4941, and NF C 63-650. Part of the Schneider Electric TeSys K range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LR2K0310, Schneider Electric LR2K0310, TeSys K overload relay, thermal motor protection relay 2.6-3.7A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065385218312,"sku":"SCHLR2K0310","price":22.12,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/lr2k0310-differential-thermal-overload-relay-tesys-k-2637a-class-10a-4686082.jpg?v=1757426698"},{"product_id":"lr2k0312-differential-thermal-overload-relay-tesys-k-3-7-5-5a-class-10a","title":"Schneider LR2K0312 TeSys K Overload Relay 3.7-5.5A Class 10A Direct Mount","description":"\u003cp\u003eThe Schneider Electric LR2K0312 is a TeSys K differential thermal overload relay for motor protection in AC and DC networks. It offers a current adjustment range of 3.7 to 5.5 A with Class 10A tripping per IEC 60947-4-1, and includes phase loss detection for reliable three-phase motor protection.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LR2K0312\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys K (TeSys LRK)\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eThermal overload adjustment: 3.7...5.5 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 690 V (IEC 60947), 750 V (VDE 0110 group C)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eThermal current (Ith): 6 A for signal circuit\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP2x per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...55 °C without change of characteristics\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor; panel or DIN rail with accessories\u003c\/li\u003e\n  \u003cli\u003eCompatible contactors: LC1K, LC7K, LP1K, LP4K\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminals, 1.5...4 mm² solid, 0.75...4 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.3 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 45 x 58 x 65 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.145 kg\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL, CSA, UKCA\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947, VDE 0660, BS 4941, NF C 63-650\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhase loss sensitivity per IEC 60947-4-1 for enhanced motor protection\u003c\/li\u003e\n  \u003cli\u003eYellow trip indicator for quick local fault identification\u003c\/li\u003e\n  \u003cli\u003eManual or automatic reset via selector switch; red test button and blue stop button included\u003c\/li\u003e\n  \u003cli\u003eDirect mounting under TeSys K contactors (LC1K, LP1K, LP4K, LC7K) without additional hardware\u003c\/li\u003e\n  \u003cli\u003eFlame retardant housing: V1 per UL 94, fire resistance at 850 °C per IEC 60695-2-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor starter assemblies in industrial control panels with TeSys K contactors\u003c\/li\u003e\n  \u003cli\u003eOverload protection for pumps, fans, and conveyors in AC and DC drive systems\u003c\/li\u003e\n  \u003cli\u003eMotor control centers requiring Class 10A trip coordination\u003c\/li\u003e\n  \u003cli\u003eLight industrial and building automation motor protection circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947, VDE 0660, BS 4941, and NF C 63-650. Part of the Schneider Electric TeSys K range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LR2K0312, Schneider Electric LR2K0312, TeSys K overload relay, thermal motor protection relay.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065385480456,"sku":"SCHLR2K0312","price":22.43,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lr2k0312-differential-thermal-overload-relay-tesys-k-3755a-class-10a-337822.jpg?v=1735247200"},{"product_id":"lr2k0314-differential-thermal-overload-relay-tesys-k-5-5-8a-class-10a","title":"Schneider LR2K0314 TeSys K Overload Relay 5.5-8A Class 10A Direct Mount","description":"\u003cp\u003eThe Schneider Electric LR2K0314 is a TeSys K differential thermal overload relay for motor protection, with a thermal overload adjustment range of 5.5 to 8 A and tripping class 10A per IEC 60947-4-1. Compatible with TeSys K contactors including LC1K, LC7K, LP1K, and LP4K, it operates on both AC and DC networks with a rated insulation voltage up to 690 V. Its compact 45 x 58 x 65 mm housing and integrated phase loss sensitivity make it a precise, space-saving motor protection device.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LR2K0314\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys K (TeSys LRK)\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eApplication: Motor protection\u003c\/li\u003e\n  \u003cli\u003eThermal overload adjustment: 5.5...8 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V (IEC 60947 \/ BS 4941), 750 V (VDE 0110 Group C), 600 V (CSA C22.2 No 14)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contact composition: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eThermal current in air [Ith]: 6 A (control circuit)\u003c\/li\u003e\n  \u003cli\u003ePower dissipation per pole: 2 W\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: Yes, per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eMounting: Direct below contactor; panel or DIN rail mounting with accessories\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminal blocks, 0.34...4 mm², tightening torque 1.3 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 45 x 58 x 65 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.145 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP2x per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...55°C without characteristic change per IEC 60947\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947, VDE 0660, NF C 63-650, BS 4941\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL, CSA, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhase loss sensitivity detects single-phasing conditions to prevent motor damage, compliant with IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eYellow trip indicator gives clear local signalling of overload trip events\u003c\/li\u003e\n  \u003cli\u003eRed button enables trip function testing; blue button allows stop and manual reset\u003c\/li\u003e\n  \u003cli\u003eSelector switch provides choice between manual and automatic reset mode for flexible fault recovery\u003c\/li\u003e\n  \u003cli\u003eDirect mounting below TeSys K contactors minimises panel space and simplifies wiring\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency tolerance up to 400 Hz suits a wide range of AC supply conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor protection in industrial automation and machine building control panels\u003c\/li\u003e\n  \u003cli\u003eDirect-on-line and reversing motor starter assemblies using TeSys K contactors\u003c\/li\u003e\n  \u003cli\u003ePump and fan motor protection in HVAC and water treatment installations\u003c\/li\u003e\n  \u003cli\u003eConveyor and compressor motor protection in manufacturing environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-4-1, VDE 0660, NF C 63-650, and BS 4941. Part of the Schneider Electric TeSys K range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LR2K0314, Schneider Electric LR2K0314, TeSys K thermal overload relay, LR2K 8A motor protection relay.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065385545992,"sku":"SCHLR2K0314","price":22.42,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lr2k0314-differential-thermal-overload-relay-tesys-k-558a-class-10a-657197.jpg?v=1735247201"},{"product_id":"lr2k0316-differential-thermal-overload-relay-tesys-k-8-11-5a-class-10a","title":"Schneider LR2K0316 TeSys K Overload Relay 8-11.5A Class 10A Direct Mount","description":"\u003cp\u003eThe Schneider Electric LR2K0316 is a TeSys K differential thermal overload relay designed for motor protection in AC and DC networks. With an adjustable thermal overload setting of 8 to 11.5 A and Class 10A trip class per IEC 60947-4-1, it provides reliable overload and phase loss protection when mounted directly below compatible TeSys K contactors.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LR2K0316\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys K (TeSys LRK)\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eRelay use: Motor protection\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 8...11.5 A\u003c\/li\u003e\n  \u003cli\u003eTrip class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 690 V per IEC 60947; 750 V per VDE 0110 group C; 600 V per CSA C22.2 No 14\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003ePermissible thermal current: 6 A (signal circuit)\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP2x per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...55 °C without change of characteristics per IEC 60947\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70 °C\u003c\/li\u003e\n  \u003cli\u003eOperating altitude: 2000 m without change of characteristics\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminal blocks, 1.5...4 mm² solid; 0.75...4 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.3 N.m\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor; panel or DIN rail with accessories\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 45 x 58 x 65 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.145 kg\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL, CSA, UKCA\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947, VDE 0660, BS 4941, NF C 63-650\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhase loss sensitivity per IEC 60947-4-1 for comprehensive motor protection\u003c\/li\u003e\n  \u003cli\u003eYellow trip indicator for immediate local fault signaling\u003c\/li\u003e\n  \u003cli\u003eRed test button for trip function verification; blue button for stop and manual reset\u003c\/li\u003e\n  \u003cli\u003eSelectable manual or automatic reset via front-panel selector switch\u003c\/li\u003e\n  \u003cli\u003eCompatible with LC1K, LC7K, LP1K, and LP4K contactors for direct mounting below the contactor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eOverload and phase loss protection for motors in industrial control panels\u003c\/li\u003e\n  \u003cli\u003eDirect-mount motor starter assemblies with TeSys K series contactors\u003c\/li\u003e\n  \u003cli\u003eAC and DC motor control circuits up to 690 V\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation and machine control equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947, VDE 0660, BS 4941, and NF C 63-650. Part of the Schneider Electric TeSys K range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LR2K0316, Schneider Electric LR2K0316, TeSys K thermal overload relay, motor overload protection relay 8-11.5A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065385578760,"sku":"SCHLR2K0316","price":22.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lr2k0316-differential-thermal-overload-relay-tesys-k-8115a-class-10a-771132.jpg?v=1735247199"},{"product_id":"lr2k0321-differential-thermal-overload-relay-tesys-k-10-14a-class-10a","title":"Schneider LR2K0321 TeSys K Overload Relay 10-14A Class 10A Direct Mount","description":"\u003cp\u003eThe Schneider Electric LR2K0321 is a TeSys K differential thermal overload relay for motor protection, with an adjustable current setting of 10 to 14 A and Class 10A trip characteristics per IEC 60947-4-1. Compatible with TeSys K contactors (LC1K, LC7K, LP1K, LP4K), it supports both AC and DC network types.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LR2K0321\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys K (TeSys LRK)\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eRelay function: Motor protection\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 10...14 A\u003c\/li\u003e\n  \u003cli\u003eTrip class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: up to 400 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 690 V (IEC 60947), 750 V (VDE 0110 group C), 600 V (CSA C22.2 No 14)\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eThermal current in air (Ith): 6 A (signal circuit)\u003c\/li\u003e\n  \u003cli\u003ePower dissipation per pole: 2 W\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: Yes\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor \/ panel or DIN rail with separate accessories\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminal blocks, 1.5...4 mm² solid, 0.75...4 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.3 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 45 x 58 x 65 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.145 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP2x (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...55°C without characteristic changes \/ -30...60°C with characteristic changes\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70°C\u003c\/li\u003e\n  \u003cli\u003eOperating altitude: up to 2000 m\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947, BS 4941, VDE 0660, NF C 63-650\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL, CSA, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhase loss sensitivity per IEC 60947-4-1 protects motors against single-phasing faults\u003c\/li\u003e\n  \u003cli\u003eYellow trip indicator for immediate visual fault identification\u003c\/li\u003e\n  \u003cli\u003eRed test button verifies trip function; blue button provides stop and manual reset\u003c\/li\u003e\n  \u003cli\u003eSelector switch for manual or automatic reset mode to suit application requirements\u003c\/li\u003e\n  \u003cli\u003eDirect-mount compatibility below TeSys K contactors reduces wiring and panel space\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor starter assemblies in industrial control panels using TeSys K contactors\u003c\/li\u003e\n  \u003cli\u003eProtection of small three-phase AC and DC motors in manufacturing and process automation\u003c\/li\u003e\n  \u003cli\u003eCompact machine tool, HVAC, and building services motor control enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-4-1, BS 4941, VDE 0660, and NF C 63-650. Part of the Schneider Electric TeSys K range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LR2K0321, Schneider Electric LR2K0321, TeSys K thermal overload relay, motor protection relay 10-14A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065385611528,"sku":"SCHLR2K0321","price":24.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lr2k0321-differential-thermal-overload-relay-tesys-k-1014a-class-10a-802117.jpg?v=1735247201"},{"product_id":"lr2k0322-differential-thermal-overload-relay-tesys-k-12-16a-class-10a","title":"Schneider LR2K0322 TeSys K Overload Relay 12-16A Class 10A Direct Mount","description":"\u003cp\u003eThe Schneider Electric LR2K0322 is a TeSys K differential thermal overload relay for motor protection, with a current adjustment range of 12 to 16 A and tripping class 10A per IEC 60947-4-1. It mounts directly below compatible TeSys K contactors (LC1K, LP1K, LP4K, LC7K) and includes built-in phase loss detection for enhanced motor safeguarding.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LR2K0322\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys LRK\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eRelay use: Motor protection\u003c\/li\u003e\n  \u003cli\u003eThermal overload adjustment: 12...16 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: up to 400 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V (IEC 60947), 750 V (VDE 0110 group C), 600 V (CSA C22.2 No 14)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contact composition: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003ePermitted thermal current [Ith]: 6 A (signal circuit)\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: Yes (IEC 60947-4-1)\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor; panel or rail with accessories\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminal blocks, 1.5...4 mm² solid, 0.75...4 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.3 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP2x (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...55 °C without derating (IEC 60947)\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 45 x 58 x 65 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.145 kg\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL, CSA, UKCA\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947, VDE 0660, NF C 63-650, BS 4941\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhase loss detection for reliable motor protection per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eSelectable manual or automatic reset via front-panel selector switch\u003c\/li\u003e\n  \u003cli\u003eYellow trip indicator for immediate local fault identification\u003c\/li\u003e\n  \u003cli\u003eDedicated red test button and blue stop\/reset button for simplified commissioning and maintenance\u003c\/li\u003e\n  \u003cli\u003eDirect contactor mounting below TeSys K devices eliminates additional wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor starter protection in industrial control panels\u003c\/li\u003e\n  \u003cli\u003eThree-phase motor protection in manufacturing and automation systems\u003c\/li\u003e\n  \u003cli\u003eDirect-mount starter assemblies with TeSys K contactors\u003c\/li\u003e\n  \u003cli\u003ePump and HVAC motor control circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947, VDE 0660, NF C 63-650, and BS 4941. Part of the Schneider Electric TeSys LRK range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LR2K0322, Schneider Electric LR2K0322, TeSys K overload relay 12-16A, thermal motor protection relay Class 10A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065385644296,"sku":"SCHLR2K0322","price":24.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lr2k0322-differential-thermal-overload-relay-tesys-k-1216a-class-10a-462637.jpg?v=1735247201"},{"product_id":"lrd01-tesys-deca-thermal-overload-relays-0-1-0-16a-class-10a","title":"Schneider LRD01 TeSys Deca Thermal Overload Relay 0.1-0.16A","description":"\u003cp\u003eThe Schneider Electric LRD01 is a TeSys LRD differential thermal overload relay designed for motor protection, with a current setting range of 0.1 to 0.16 A and tripping class 10A per IEC 60947-4-1. It mounts directly below compatible TeSys D contactors and operates on both AC and DC networks across the full frequency range of 0 to 400 Hz.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LRD01\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys LRD \/ TeSys Deca\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eRelay function: Motor protection\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 0.1...0.16 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eTripping threshold: 1.14 +\/- 0.06 Ir per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 0...400 Hz\u003c\/li\u003e\n  \u003cli\u003eRated voltage [ue]: 690 V AC for power circuit per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [ui]: 690 V per IEC 60947-4-1; 600 V per UL \/ CSA\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contact: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eThermal current [ith]: 5 A for signal circuit\u003c\/li\u003e\n  \u003cli\u003eAssociated fuse: 4 A gG \/ 4 A BS for signal circuit\u003c\/li\u003e\n  \u003cli\u003eControl: Red button (stop), Blue button (reset)\u003c\/li\u003e\n  \u003cli\u003eConnection type: Screw terminal blocks - power circuit 1 cable 1...6 mm² single-core; control circuit 2 cables 1...2.5 mm²\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.7 N.m (power and control circuits)\u003c\/li\u003e\n  \u003cli\u003eCompatible contactors: LC1D09, LC1D12, LC1D18, LC1D25, LC1D32, LC1D38\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor, plate or DIN rail (with accessories)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 45 x 66 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.124 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...60°C per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -60...70°C\u003c\/li\u003e\n  \u003cli\u003eDielectric strength: 1.89 kV at 50 Hz per IEC 60947-1\u003c\/li\u003e\n  \u003cli\u003eFlame resistance: V1 per UL 94\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS, ATEX INERIS, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhase loss sensitivity: triggers at 130% of Ir with two phases active and the third at zero\u003c\/li\u003e\n  \u003cli\u003eTemperature compensation across -20...60°C ensures consistent tripping characteristics\u003c\/li\u003e\n  \u003cli\u003eDirect mounting below TeSys D contactors reduces panel space and wiring\u003c\/li\u003e\n  \u003cli\u003eVibration resistance to 6 Gn and shock resistance to 15 Gn for 11 ms suits demanding industrial environments\u003c\/li\u003e\n  \u003cli\u003eWide certification portfolio including ATEX INERIS and marine classifications (DNV-GL, RINA, LROS)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eProtection of small fractional-horsepower motors in conveyor and automation systems\u003c\/li\u003e\n  \u003cli\u003eMotor starter assemblies paired with TeSys D LC1D contactors in control panels\u003c\/li\u003e\n  \u003cli\u003eHVAC and pump motor circuits requiring reliable thermal overload protection\u003c\/li\u003e\n  \u003cli\u003eMarine and hazardous-area installations requiring ATEX or marine-certified components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB\/T 14048.4, and EN 50495. Part of the Schneider Electric TeSys Deca range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LRD01, Schneider Electric LRD01, TeSys thermal relay 0.16A, motor overload relay LRD01.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065385971976,"sku":"SCHLRD01","price":20.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lrd01-tesys-deca-thermal-overload-relays01016aclass-10a-298641.jpg?v=1735247252"},{"product_id":"lrd02-tesys-deca-thermal-overload-relays-0-16-0-25a-class-10a","title":"Schneider LRD02 TeSys Deca Thermal Overload Relay 0.16-0.25A","description":"\u003cp\u003eThe Schneider Electric LRD02 is a TeSys LRD thermal overload relay for motor protection, adjustable from 0.16 to 0.25 A with tripping class 10A per IEC 60947-4-1. It mounts directly below TeSys D contactors (LC1D09 to LC1D38) and operates on both AC and DC networks up to 690 V.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LRD02\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys LRD \/ TeSys Deca\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 0.16...0.25 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC, 0...400 Hz\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 690 V AC per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contact: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: Trips at 130% Ir in two phases, last phase at 0\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...60 °C per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -60...70 °C\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 45 x 66 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.124 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminal blocks, power circuit 1.5...10 mm², tightening torque 1.7 N.m\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor, DIN rail or panel (with accessories)\u003c\/li\u003e\n  \u003cli\u003eCompatible contactors: LC1D09, LC1D12, LC1D18, LC1D25, LC1D32, LC1D38\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, UKCA, ATEX INERIS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect mounting below TeSys D contactors for compact motor starter assemblies\u003c\/li\u003e\n  \u003cli\u003ePhase loss protection triggers at 130% Ir for enhanced motor safety\u003c\/li\u003e\n  \u003cli\u003eRed stop button and blue reset button for manual control and easy fault recovery\u003c\/li\u003e\n  \u003cli\u003eTemperature compensation from -20 to 60 °C ensures stable tripping characteristics\u003c\/li\u003e\n  \u003cli\u003eFlame resistance V1 per UL 94 and IP20 enclosure for safe industrial panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eProtection of small AC and DC motors in industrial automation panels\u003c\/li\u003e\n  \u003cli\u003eMotor starter combinations with TeSys D contactors\u003c\/li\u003e\n  \u003cli\u003ePump, fan, and conveyor motor protection in light industrial environments\u003c\/li\u003e\n  \u003cli\u003eMarine and hazardous area installations (DNV-GL, BV, ATEX INERIS certified)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and EN 50495. Part of the Schneider Electric TeSys Deca range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LRD02, Schneider Electric LRD02, TeSys thermal overload relay, motor overload relay.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065386004744,"sku":"SCHLRD02","price":21.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lrd02-tesys-deca-thermal-overload-relays016025aclass-10a-335667.jpg?v=1735247255"},{"product_id":"lrd03-tesys-deca-thermal-overload-relays-0-25-0-4a-class-10a","title":"Schneider LRD03 TeSys Deca Thermal Overload Relay 0.25-0.4A","description":"\u003cp\u003eThe Schneider Electric LRD03 is a TeSys LRD differential thermal overload relay designed for motor protection, with a thermal overload setting range of 0.25 to 0.4 A and tripping class 10A per IEC 60947-4-1. Compatible with TeSys D contactors LC1D09 through LC1D38, it protects AC and DC motors against overload and phase loss on networks up to 690 V.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LRD03\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys LRD, TeSys Deca\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eRelay function: Motor protection\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 0.25...0.4 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 0...400 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping threshold: 1.14 +\/- 0.06 Ir per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: Tripping at 130% of Ir on two phases, last phase at 0\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V per IEC 60947-4-1; 600 V per UL \/ CSA\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 690 V AC, 0...400 Hz per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eDielectric strength: 1.89 kV at 50 Hz per IEC 60947-1\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eThermal current [Ith]: 5 A (control circuit)\u003c\/li\u003e\n  \u003cli\u003ePermissible current: 3 A at 120 V AC-15; 0.22 A at 125 V DC-13 (control circuit)\u003c\/li\u003e\n  \u003cli\u003eAssociated fuse: 4 A gG \/ 4 A BS (control circuit)\u003c\/li\u003e\n  \u003cli\u003eConnection - power circuit: screw terminals, 1.5...10 mm² flexible \/ 1...4 mm² flexible with ferrule \/ 1...6 mm² solid\u003c\/li\u003e\n  \u003cli\u003eConnection - control circuit: screw terminals, 1...2.5 mm² flexible or solid\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.7 N.m (power and control circuits)\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor; DIN rail or panel with accessories\u003c\/li\u003e\n  \u003cli\u003eTemperature compensation: -20...60°C\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...60°C per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -60...70°C\u003c\/li\u003e\n  \u003cli\u003eFlame resistance: V1 per UL 94\u003c\/li\u003e\n  \u003cli\u003eMechanical robustness: Vibrations 6 Gn per IEC 60068-2-6; Shocks 15 Gn for 11 ms per IEC 60068-2-7\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 45 x 66 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.124 kg\u003c\/li\u003e\n  \u003cli\u003eCompatible contactors: LC1D09, LC1D12, LC1D18, LC1D25, LC1D32, LC1D38\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS, ATEX INERIS, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eClass 10A tripping characteristic provides reliable overload protection for standard AC and DC motor applications\u003c\/li\u003e\n  \u003cli\u003ePhase loss detection activates at 130% of rated current on two phases, preventing single-phase motor damage\u003c\/li\u003e\n  \u003cli\u003eIntegrated 1 NO + 1 NC auxiliary contact enables signaling, interlocking, and remote monitoring in control circuits\u003c\/li\u003e\n  \u003cli\u003eRed stop and blue reset push buttons allow direct manual control and fault reset at the relay\u003c\/li\u003e\n  \u003cli\u003eWide temperature compensation range (-20 to 60°C) maintains consistent tripping behavior across demanding environments\u003c\/li\u003e\n  \u003cli\u003eDirect mounting below TeSys D contactors simplifies wiring and reduces overall panel footprint\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor starter assemblies for industrial machinery, conveyors, and pumps requiring thermal overload protection\u003c\/li\u003e\n  \u003cli\u003eHVAC fan and pump motor control panels built around TeSys D contactor starters\u003c\/li\u003e\n  \u003cli\u003eMachine tool control panels where thermal overload and phase-loss protection is required\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore motor control applications (certified by DNV-GL, BV, and RINA)\u003c\/li\u003e\n  \u003cli\u003eHazardous area motor starters requiring ATEX INERIS certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB\/T 14048.4, GB\/T 14048.5, and EN 50495. Part of the Schneider Electric TeSys Deca range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LRD03, Schneider Electric LRD03, TeSys thermal overload relay, motor protection relay 0.25-0.4A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065387151624,"sku":"SCHLRD03","price":23.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lrd03-tesys-deca-thermal-overload-relays02504aclass-10a-833156.jpg?v=1735247252"},{"product_id":"lrd04-tesys-deca-thermal-overload-relays-0-4-0-63a-class-10a","title":"Schneider LRD04 TeSys Deca Thermal Overload Relay 0.4-0.63A","description":"\u003cp\u003eThe Schneider Electric LRD04 is a TeSys LRD differential thermal overload relay for motor protection. It features a thermal overload setting range of 0.4 to 0.63 A with Class 10A tripping per IEC 60947-4-1, and mounts directly below LC1D-series contactors for compact panel integration on AC and DC networks up to 690 V.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LRD04\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys LRD \/ TeSys Deca\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 0.4...0.63 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC, 0...400 Hz\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 690 V AC per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eTripping threshold: 1.14 +\/- 0.06 Ir per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: trips at 130% Ir in two phases, last phase at 0\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eThermal current [Ith]: 5 A (signal circuit)\u003c\/li\u003e\n  \u003cli\u003eCompatible contactors: LC1D09, LC1D12, LC1D18, LC1D25, LC1D32, LC1D38\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor, panel or DIN rail (with accessories)\u003c\/li\u003e\n  \u003cli\u003eConnection type: Screw terminal blocks; power circuit 1...6 mm² solid \/ 1.5...10 mm² flexible; control circuit 1...2.5 mm²\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.7 N.m (power and control circuits)\u003c\/li\u003e\n  \u003cli\u003eTemperature compensation: -20...60 °C\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...60 °C per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -60...70 °C\u003c\/li\u003e\n  \u003cli\u003eDielectric strength: 1.89 kV at 50 Hz per IEC 60947-1\u003c\/li\u003e\n  \u003cli\u003eVibration resistance: 6 Gn per IEC 60068-2-6\u003c\/li\u003e\n  \u003cli\u003eShock resistance: 15 Gn for 11 ms per IEC 60068-2-7\u003c\/li\u003e\n  \u003cli\u003eFlame resistance: V1 per UL 94\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 45 x 66 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.124 kg\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS, ATEX, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhase loss detection trips at 130% Ir when two phases carry current and the last is at 0, protecting against single-phasing damage\u003c\/li\u003e\n  \u003cli\u003eDirect mounting below LC1D contactors reduces panel wiring and overall footprint\u003c\/li\u003e\n  \u003cli\u003eRed stop button and blue reset button allow manual stop and reset after tripping\u003c\/li\u003e\n  \u003cli\u003eWide temperature compensation from -20 to 60 °C maintains consistent tripping accuracy across varying ambient conditions\u003c\/li\u003e\n  \u003cli\u003eAuxiliary 1 NO + 1 NC contact provides signalling and remote fault indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor protection in direct-on-line starters within industrial automation panels\u003c\/li\u003e\n  \u003cli\u003ePump, fan, and compressor motor control in process and building installations\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore motor control panels (DNV-GL and LROS certified)\u003c\/li\u003e\n  \u003cli\u003eHazardous area control systems (ATEX certified)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB\/T 14048.4, and EN 50495. Part of the Schneider Electric TeSys Deca range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LRD04, Schneider Electric LRD04, TeSys thermal overload relay, motor overload protection relay.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065387217160,"sku":"SCHLRD04","price":23.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lrd04-tesys-deca-thermal-overload-relays04063aclass-10a-341914.jpg?v=1735247316"},{"product_id":"lrd05-tesys-deca-thermal-overload-relays-0-63-1a-class-10a","title":"Schneider LRD05 TeSys Deca Thermal Overload Relay 0.63-1A","description":"\u003cp\u003eThe Schneider Electric LRD05 is a TeSys LRD thermal overload relay with a current setting range of 0.63-1 A, designed for motor protection in AC and DC networks. Part of the TeSys Deca range, it delivers tripping class 10A per IEC 60947-4-1 and mounts directly below LC1D-series contactors for a compact, integrated motor starter assembly.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LRD05\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys LRD \/ TeSys Deca\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eRelay application: Motor protection\u003c\/li\u003e\n  \u003cli\u003eCurrent setting range: 0.63-1 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC, 0-400 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V (IEC 60947-4-1), 600 V (UL\/CSA)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eTripping threshold: 1.14 +\/- 0.06 Ir per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contact: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eCompatible contactors: LC1D09, LC1D12, LC1D18, LC1D25, LC1D32, LC1D38\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor, on panel or DIN rail (with separate accessories)\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminal blocks; power circuit 1.5-10 mm², control circuit 1-2.5 mm²\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...60 °C per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -60...70 °C\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 45 x 66 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.124 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhase loss sensitivity: trips at 130% of Ir on two phases with the last phase at zero, guarding against single-phasing damage\u003c\/li\u003e\n  \u003cli\u003eTemperature compensation across the full -20...60 °C operating range ensures accurate, consistent tripping\u003c\/li\u003e\n  \u003cli\u003eIntegrated red stop button and blue reset button for convenient local manual control\u003c\/li\u003e\n  \u003cli\u003eDirect plug-in mounting below LC1D contactors eliminates additional wiring for a compact motor starter\u003c\/li\u003e\n  \u003cli\u003eBroad certification portfolio including ATEX INERIS, UKCA, and marine approvals (DNV-GL, BV, RINA, LROS) for demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor protection in industrial motor control centers and automation panels\u003c\/li\u003e\n  \u003cli\u003eCombined motor starters assembled with LC1D09 through LC1D38 contactors\u003c\/li\u003e\n  \u003cli\u003ePump, fan, and compressor drive overload protection\u003c\/li\u003e\n  \u003cli\u003eMarine and hazardous area installations requiring DNV-GL, BV, or ATEX certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and GB\/T 14048.4. Part of the Schneider Electric TeSys Deca range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LRD05, Schneider Electric LRD05, TeSys thermal relay, motor overload relay 1A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065388429576,"sku":"SCHLRD05","price":21.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lrd05-tesys-deca-thermal-overload-relays0631aclass-10a-668044.jpg?v=1735247312"},{"product_id":"lrd06-tesys-deca-thermal-overload-relays-1-1-6a-class-10a","title":"Schneider LRD06 Electric LRD06 TeSys Deca Thermal Overload Relay 1-1.6 A","description":"\u003cp\u003eThe Schneider Electric LRD06 is a TeSys LRD differential thermal overload relay for motor protection, with an adjustable current setting of 1 to 1.6 A and class 10A tripping per IEC 60947-4-1. It mounts directly under TeSys LC1D09 through LC1D38 contactors and protects AC and DC motor circuits rated up to 690 V across a frequency range of 0 to 400 Hz.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LRD06\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys LRD \/ TeSys Deca\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 1...1.6 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC, 0...400 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 690 V per IEC 60947-4-1; 600 V per UL\/CSA\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contact: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eThermal current in air: 5 A (signal circuit)\u003c\/li\u003e\n  \u003cli\u003eMounting: Under contactor; panel or DIN rail with accessories\u003c\/li\u003e\n  \u003cli\u003eConnection - control circuit: Screw terminals, 2 x 1...2.5 mm²\u003c\/li\u003e\n  \u003cli\u003eConnection - power circuit: Screw terminals, 1 x 1...6 mm² solid, 1 x 1.5...10 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.7 N.m (control and power circuits)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -60...70 °C\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 45 x 66 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.124 kg\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, ATEX INERIS, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAdjustable 1 to 1.6 A overload setting with class 10A tripping characteristic per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003ePhase-loss sensitivity: trips at 130% of Ir when one phase is lost, last phase at 0\u003c\/li\u003e\n  \u003cli\u003eIntegrated red stop button and blue manual reset button on the relay body\u003c\/li\u003e\n  \u003cli\u003eTemperature compensation maintained from -20 to 60 °C without change in tripping characteristics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor starter assemblies with TeSys LC1D contactors in industrial control panels\u003c\/li\u003e\n  \u003cli\u003eOverload and phase-loss protection for three-phase motors in AC and DC systems\u003c\/li\u003e\n  \u003cli\u003ePump, fan, and compressor circuits in manufacturing and process automation\u003c\/li\u003e\n  \u003cli\u003eMarine, offshore, and ATEX hazardous-area motor protection installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB\/T 14048.4, and EN 50495. Part of the Schneider Electric TeSys Deca range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LRD06, Schneider Electric LRD06, TeSys thermal overload relay, motor overload protection relay 1-1.6 A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065388527880,"sku":"SCHLRD06","price":23.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lrd06-tesys-deca-thermal-overload-relays116aclass-10a-655393.jpg?v=1735247315"},{"product_id":"lrd07-tesys-deca-thermal-overload-relays-1-6-2-5a-class-10a","title":"Schneider LRD07 Electric LRD07 TeSys Deca Thermal Overload Relay 1.6-2.5 A","description":"\u003cp\u003eThe Schneider Electric LRD07 is a TeSys LRD differential thermal overload relay for motor protection, with a current adjustment range of 1.6 to 2.5 A and Class 10A tripping per IEC 60947-4-1. Rated for power circuits up to 690 V AC across 0 to 400 Hz, it mounts directly below compatible TeSys Deca contactors for a compact panel assembly.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LRD07\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys LRD \/ TeSys Deca\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eApplication: Motor protection\u003c\/li\u003e\n  \u003cli\u003eCurrent adjustment range: 1.6...2.5 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 690 V AC, 0...400 Hz per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V (IEC 60947-4-1); 600 V (UL \/ CSA)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTripping threshold: 1.14 +\/- 0.06 Ir per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003ePhase loss tripping current: 130% of Ir in two phases, last phase at 0\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contact: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003ePermissible thermal current [Ith]: 5 A (control circuit)\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor; panel or DIN rail with accessory\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminal blocks - power circuit 1.5...10 mm², control circuit 1...2.5 mm²\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.7 N.m (power and control circuits)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 45 x 66 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.124 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...60 °C per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -60...70 °C\u003c\/li\u003e\n  \u003cli\u003eCompatible contactors: LC1D09, LC1D12, LC1D18, LC1D25, LC1D32, LC1D38\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS, ATEX INERIS, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eClass 10A tripping characteristic provides reliable motor overload protection per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity trips at 130% of Ir in two phases, protecting motors from single-phase operation\u003c\/li\u003e\n  \u003cli\u003eTemperature compensation across -20 to 60 °C maintains accurate tripping performance over a wide ambient range\u003c\/li\u003e\n  \u003cli\u003eDirect below-contactor mounting reduces panel space and simplifies wiring\u003c\/li\u003e\n  \u003cli\u003eRed stop button and blue reset button allow direct manual control and local reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor overload protection in industrial automation and machine control panels\u003c\/li\u003e\n  \u003cli\u003eThermal protection for pump, fan, and compressor motor circuits\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore control panels (certified by DNV-GL, BV, RINA, and LROS)\u003c\/li\u003e\n  \u003cli\u003eHazardous area installations requiring ATEX-certified overload protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB\/T 14048.4, and EN 50495. Part of the Schneider Electric TeSys Deca range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LRD07, Schneider Electric LRD07, TeSys thermal overload relay, motor protection relay 2.5A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065388560648,"sku":"SCHLRD07","price":21.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lrd07-tesys-deca-thermal-overload-relays1625aclass-10a-372312.jpg?v=1735247314"},{"product_id":"lrd08-tesys-deca-thermal-overload-relays-3p-2-5-4a-class-10a","title":"Schneider LRD08 TeSys Deca Thermal Overload Relay 2.5-4A","description":"\u003cp\u003eThe Schneider Electric LRD08 is a TeSys LRD differential thermal overload relay with a 2.5-4 A adjustment range, designed for motor protection in industrial applications. It provides Class 10A tripping performance per IEC 60947-4-1 and mounts directly below compatible TeSys D contactors including LC1D09, LC1D12, LC1D18, LC1D25, LC1D32, and LC1D38.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LRD08\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys Deca\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eApplication: Motor protection\u003c\/li\u003e\n  \u003cli\u003eThermal overload adjustment: 2.5-4 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eTripping threshold: 1.14 +\/- 0.06 Ir per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: Trips at 130% of Ir in two phases, last phase at 0\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 0-400 Hz\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 690 V AC per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V per IEC 60947-4-1; 600 V per UL and CSA\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contact: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eThermal current in air [Ith]: 5 A (control circuit)\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor; plate or DIN rail with accessories\u003c\/li\u003e\n  \u003cli\u003eConnection type: Screw terminal blocks\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.7 N.m (power and control circuits)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 45 x 66 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.124 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20-60°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -60-70°C\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB\/T 14048.4, EN 50495\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, ATEX, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMounts directly below TeSys D contactors for compact, integrated motor starter assemblies\u003c\/li\u003e\n  \u003cli\u003eBuilt-in phase loss sensitivity detects single-phasing and trips at 130% of Ir\u003c\/li\u003e\n  \u003cli\u003eTemperature compensation across -20-60°C maintains consistent tripping accuracy\u003c\/li\u003e\n  \u003cli\u003eRed stop and blue reset push buttons for straightforward manual control and reset\u003c\/li\u003e\n  \u003cli\u003eBroad global certification including ATEX, UKCA, DNV-GL, and LROS for marine and hazardous environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor protection in industrial control and automation panels\u003c\/li\u003e\n  \u003cli\u003ePump and conveyor motor starter assemblies\u003c\/li\u003e\n  \u003cli\u003eHVAC motor protection circuits\u003c\/li\u003e\n  \u003cli\u003eMachine tool and compressor motor control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-4-1 and EN\/IEC 60947-5-1. Part of the Schneider Electric TeSys Deca range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LRD08, Schneider Electric LRD08, TeSys thermal overload relay 2.5-4A, motor protection relay LRD08.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065388593416,"sku":"SCHLRD08","price":21.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lrd08-tesys-deca-thermal-overload-relays3p254aclass-10a-722707.jpg?v=1735247312"},{"product_id":"lrd10-tesys-deca-thermal-overload-relays-3p-4-6a-class-10a","title":"Schneider LRD10 LRD10 Thermal Overload Relay 4-6A Class 10 for LC1D Contactors","description":"\u003cp\u003eThe Schneider Electric LRD10 is a TeSys LRD differential thermal overload relay with an adjustable current range of 4 to 6 A, designed for motor protection in AC and DC power circuits. Featuring Class 10A trip characteristics per IEC 60947-4-1 and built-in phase loss detection, it mounts directly below compatible LC1D contactors for a compact motor starter assembly.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LRD10\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys LRD \/ TeSys Deca\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eApplication: Motor protection\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 4...6 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 0...400 Hz\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 690 V AC per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V per IEC 60947-4-1; 600 V per UL \/ CSA\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eTripping threshold: 1.14 +\/- 0.06 Ir per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: tripping at 130% of Ir in two phases, last phase at 0\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eThermal current in air [Ith]: 5 A (signal circuit)\u003c\/li\u003e\n  \u003cli\u003ePermissible current: 3 A at 120 V AC-15 \/ 0.22 A at 125 V DC-13 (signal circuit)\u003c\/li\u003e\n  \u003cli\u003eAssociated fuse: 4 A gG \/ 4 A BS (signal circuit)\u003c\/li\u003e\n  \u003cli\u003eTemperature compensation: -20...60 °C\u003c\/li\u003e\n  \u003cli\u003eCompatible contactors: LC1D09, LC1D12, LC1D18, LC1D25, LC1D32, LC1D38\u003c\/li\u003e\n  \u003cli\u003eMounting: below contactor; panel or DIN rail with accessories\u003c\/li\u003e\n  \u003cli\u003eControl circuit connection: screw terminals, 1...2.5 mm² (flexible or solid)\u003c\/li\u003e\n  \u003cli\u003ePower circuit connection: screw terminals, 1.5...10 mm² flexible \/ 1...6 mm² solid\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.7 N.m (control and power circuit screw terminals)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 45 x 66 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.124 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...60 °C per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -60...70 °C\u003c\/li\u003e\n  \u003cli\u003eDielectric strength: 1.89 kV at 50 Hz per IEC 60947-1\u003c\/li\u003e\n  \u003cli\u003eVibration resistance: 6 Gn per IEC 60068-2-6\u003c\/li\u003e\n  \u003cli\u003eShock resistance: 15 Gn for 11 ms per IEC 60068-2-7\u003c\/li\u003e\n  \u003cli\u003eFlame resistance: V1 per UL 94\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, GB\/T 14048.4, GB\/T 14048.5, EN 50495\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS, ATEX INERIS, UKCA\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect mounting below LC1D contactors eliminates additional wiring for a space-saving motor starter\u003c\/li\u003e\n  \u003cli\u003ePhase loss detection trips at 130% of Ir in two phases, preventing single-phase motor damage\u003c\/li\u003e\n  \u003cli\u003eRed stop and blue reset push buttons for local manual control and fault reset\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range with stable tripping characteristics from -20 to 60 °C\u003c\/li\u003e\n  \u003cli\u003eBroad certification portfolio covering IEC, UL, CSA, ATEX, and UKCA for global deployment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor protection in industrial automation panels and control cabinets\u003c\/li\u003e\n  \u003cli\u003eThree-phase motor starters combined with LC1D09 to LC1D38 contactors\u003c\/li\u003e\n  \u003cli\u003ePumps, fans, compressors, and conveyor drive protection\u003c\/li\u003e\n  \u003cli\u003eMarine and hazardous-area installations (ATEX INERIS, DNV-GL, LROS certified)\u003c\/li\u003e\n  \u003cli\u003eAC and DC motor control circuits up to 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB\/T 14048.4, and EN 50495. Part of the Schneider Electric TeSys Deca range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LRD10, Schneider Electric LRD10, TeSys LRD thermal overload relay, motor protection relay 4-6A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065388691720,"sku":"SCHLRD10","price":21.77,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lrd10-tesys-deca-thermal-overload-relays3p46aclass-10a-201636.jpg?v=1735247312"},{"product_id":"lrd12-tesys-deca-thermal-overload-relay-5-5-8a-class-10a","title":"Schneider LRD12 TeSys Deca Thermal Overload Relay 5.5-8A","description":"\u003cp\u003eThe Schneider Electric LRD12 is a TeSys Deca thermal overload relay with a 5.5 to 8 A setting range, designed for motor protection on AC and DC circuits. It delivers Class 10A tripping per IEC 60947-4-1 and mounts directly below TeSys D contactors LC1D09 through LC1D38, simplifying motor starter assemblies.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LRD12\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys LRD, TeSys Deca\u003c\/li\u003e\n  \u003cli\u003eProduct type: Thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eApplication: Motor protection\u003c\/li\u003e\n  \u003cli\u003eOverload setting range: 5.5...8 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eRated voltage: 690 V AC, 0...400 Hz per IEC 60947-4-1; 600 V per UL and CSA\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eTripping threshold: 1.14 +\/- 0.06 Ir per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: 130% of Ir on two phases, last phase at 0\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eCompatible contactors: LC1D09, LC1D12, LC1D18, LC1D25, LC1D32, LC1D38\u003c\/li\u003e\n  \u003cli\u003eMounting: below contactor; plate or DIN rail with separate accessories\u003c\/li\u003e\n  \u003cli\u003eConnection - supply circuit: screw terminals, 1...6 mm² solid \/ 1.5...10 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eConnection - control circuit: screw terminals, 1...2.5 mm² solid or flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.7 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...60 °C per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -60...70 °C\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 45 x 66 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.124 kg\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS, ATEX INERIS, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eClass 10A tripping per IEC 60947-4-1 ensures accurate motor overload protection\u003c\/li\u003e\n  \u003cli\u003ePhase loss detection trips at 130% of Ir on two phases with the last phase at 0\u003c\/li\u003e\n  \u003cli\u003eTemperature compensation across -20 to 60 °C maintains consistent trip performance\u003c\/li\u003e\n  \u003cli\u003eDirect below-contactor mounting with LC1D09 to LC1D38 reduces panel wiring\u003c\/li\u003e\n  \u003cli\u003eIntegrated 1 NO + 1 NC auxiliary contact for signaling and circuit interlocking\u003c\/li\u003e\n  \u003cli\u003eRed stop button and blue reset button for manual operation and fault reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor overload protection in industrial automation and control panels\u003c\/li\u003e\n  \u003cli\u003eMotor starter assemblies paired with TeSys D contactors\u003c\/li\u003e\n  \u003cli\u003eAC and DC motor control in manufacturing and process equipment\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore control systems requiring DNV-GL or LROS approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, GB\/T 14048.4, and EN 50495. Part of the Schneider Electric TeSys Deca range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LRD12, Schneider Electric LRD12, TeSys thermal overload relay 5.5-8A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065388724488,"sku":"SCHLRD12","price":22.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lrd12-tesys-deca-thermal-overload-relay558aclass-10a-771205.jpg?v=1735247314"},{"product_id":"lrd14-tesys-deca-thermal-overload-relays-3p-7-10a-class-10a","title":"Schneider LRD14 TeSys Deca Thermal Overload Relay 7-10A","description":"\u003cp\u003eThe Schneider Electric LRD14 is a TeSys LRD differential thermal overload relay with a current adjustment range of 7 to 10 A, designed for motor protection in AC and DC networks. Featuring tripping class 10A per IEC 60947-4-1 and phase loss sensitivity, it mounts directly below LC1D series contactors for compact starter assemblies.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LRD14\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys LRD, TeSys Deca\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eRelay use: Motor protection\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, DC\u003c\/li\u003e\n  \u003cli\u003eOverload tripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eThermal overload adjustment: 7...10 A\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V per IEC 60947-4-1; 600 V per UL\/CSA\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 690 V AC, 0...400 Hz (power circuit)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 0...400 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping threshold: 1.14 +\/- 0.06 Ir per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: Trip at 130% of Ir in two phases, last phase at 0\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contact composition: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003ePermissible thermal current [Ith]: 5 A (signal circuit)\u003c\/li\u003e\n  \u003cli\u003eCompatible contactors: LC1D09, LC1D12, LC1D18, LC1D25, LC1D32, LC1D38\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor; panel or DIN rail with accessories\u003c\/li\u003e\n  \u003cli\u003eConnection - power circuit: Screw terminals, 1 cable 1.5...10 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eConnection - control circuit: Screw terminals, 2 cables 1...2.5 mm²\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1.7 N.m (power and control circuits)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 45 x 66 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.124 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...60°C per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -60...70°C\u003c\/li\u003e\n  \u003cli\u003eDielectric strength: 1.89 kV at 50 Hz per IEC 60947-1\u003c\/li\u003e\n  \u003cli\u003eFlame resistance: V1 per UL 94\u003c\/li\u003e\n  \u003cli\u003eVibration resistance: 6 Gn per IEC 60068-2-6\u003c\/li\u003e\n  \u003cli\u003eShock resistance: 15 Gn for 11 ms per IEC 60068-2-7\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS, ATEX INERIS, UKCA\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB\/T 14048.4, EN 50495\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMounts directly below LC1D contactors, reducing panel wiring and saving installation space\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity trips at 130% of Ir with one phase at zero, protecting motors from single-phasing damage\u003c\/li\u003e\n  \u003cli\u003eTemperature compensation across -20...60°C ensures consistent tripping accuracy in varying ambient conditions\u003c\/li\u003e\n  \u003cli\u003eIntegrated 1 NO + 1 NC auxiliary contact enables alarm signaling and control circuit interlocking\u003c\/li\u003e\n  \u003cli\u003eRed stop and blue reset manual control buttons allow direct local operation\u003c\/li\u003e\n  \u003cli\u003eBroad global certification portfolio including ATEX, DNV-GL, and UKCA for hazardous and marine applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor overload protection in industrial automation and machine control panels\u003c\/li\u003e\n  \u003cli\u003eDirect-on-line and reversing starter assemblies with TeSys LC1D contactors\u003c\/li\u003e\n  \u003cli\u003ePump, fan, and compressor motor protection in HVAC and building services\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling drive protection\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore motor control panels requiring DNV-GL or LROS certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB\/T 14048.4, and EN 50495. Part of the Schneider Electric TeSys Deca range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LRD14, Schneider Electric LRD14, TeSys thermal overload relay 7-10A, motor protection relay LRD14.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065388822792,"sku":"SCHLRD14","price":21.77,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lrd14-tesys-deca-thermal-overload-relays3p710aclass-10a-650134.jpg?v=1735247313"},{"product_id":"lrd16-tesys-deca-thermal-overload-relay-9-13a-class-10a","title":"Schneider LRD16 TeSys Deca Thermal Overload Relay 9-13A","description":"\u003cp\u003eThe Schneider Electric LRD16 is a TeSys Deca differential thermal overload relay for motor protection, with an adjustable current setting of 9 to 13 A and trip class 10A per IEC 60947-4-1. Compatible with TeSys D contactors LC1D12, LC1D18, LC1D25, LC1D32, and LC1D38, it operates on both AC and DC networks up to 690 V.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LRD16\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys Deca \/ TeSys LRD\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eApplication: Motor protection\u003c\/li\u003e\n  \u003cli\u003eThermal overload adjustment: 9...13 A\u003c\/li\u003e\n  \u003cli\u003eTrip class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC, 0...400 Hz\u003c\/li\u003e\n  \u003cli\u003eRated voltage (Ue): 690 V AC per IEC 60947-4-1; 600 V per UL \/ CSA\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eTripping threshold: 1.14 +\/- 0.06 Ir per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: 130% of Ir with two phases active, last phase at 0\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...60 °C\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor, panel, or DIN rail (with accessories)\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminal blocks\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 45 x 66 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.124 kg\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS, ATEX INERIS, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAdjustable 9 to 13 A thermal overload setting for accurate motor protection\u003c\/li\u003e\n  \u003cli\u003ePhase loss detection - trips at 130% of Ir with two phases active, last phase at 0\u003c\/li\u003e\n  \u003cli\u003e1 NO + 1 NC auxiliary contact for alarm or control circuit integration\u003c\/li\u003e\n  \u003cli\u003eRed stop button and blue reset button for local manual operation\u003c\/li\u003e\n  \u003cli\u003eTemperature compensation over -20 to 60 °C for consistent tripping accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor protection in industrial control and automation panels\u003c\/li\u003e\n  \u003cli\u003eDirect mounting on TeSys D contactors in motor starter assemblies\u003c\/li\u003e\n  \u003cli\u003eProtection of pumps, fans, and compressors in process installations\u003c\/li\u003e\n  \u003cli\u003eMarine and hazardous area installations (ATEX INERIS, DNV-GL, RINA certified)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB\/T 14048.4, GB\/T 14048.5, and EN 50495. Part of the Schneider Electric TeSys Deca range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LRD16, Schneider Electric LRD16, TeSys thermal overload relay 9-13A, motor protection relay 9-13A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065388888328,"sku":"SCHLRD16","price":21.78,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lrd16-tesys-deca-thermal-overload-relay913aclass-10a-694351.jpg?v=1735247315"},{"product_id":"lrd21-tesys-deca-thermal-overload-relay-12-18a-class-10a","title":"Schneider LRD21 TeSys Deca Thermal Overload Relay 12-18A","description":"\u003cp\u003eThe Schneider Electric LRD21 is a TeSys Deca thermal overload relay rated for 12 to 18 A with Class 10A tripping per IEC 60947-4-1. Designed for motor protection, it mounts directly below TeSys D contactors (LC1D18 to LC1D38) and operates on both AC and DC networks up to 690 V at frequencies from 0 to 400 Hz.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LRD21\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys Deca (TeSys LRD)\u003c\/li\u003e\n  \u003cli\u003eProduct type: Thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eApplication: Motor protection\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 12...18 A\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 690 V AC, 0...400 Hz (power circuit, IEC 60947-4-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V (IEC) \/ 600 V (UL, CSA)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eTripping threshold: 1.14 +\/- 0.06 Ir per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: trips at 130% of Ir in two phases, last phase at 0\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003ePermissible thermal current [Ith]: 5 A (signal circuit)\u003c\/li\u003e\n  \u003cli\u003eCompatible contactors: LC1D18, LC1D25, LC1D32, LC1D38\u003c\/li\u003e\n  \u003cli\u003eConnection - power circuit: screw terminals, 1 cable 1...6 mm² solid \/ 1.5...10 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eConnection - control circuit: screw terminals, 2 cables 1...2.5 mm²\u003c\/li\u003e\n  \u003cli\u003eTightening torque - power circuit: 2.5 N.m\u003c\/li\u003e\n  \u003cli\u003eTightening torque - control circuit: 1.7 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 45 x 66 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.124 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -60...70 °C\u003c\/li\u003e\n  \u003cli\u003eDielectric strength: 1.89 kV at 50 Hz per IEC 60947-1\u003c\/li\u003e\n  \u003cli\u003eFlame resistance: V1 per UL 94\u003c\/li\u003e\n  \u003cli\u003eVibration resistance: 6 Gn per IEC 60068-2-6\u003c\/li\u003e\n  \u003cli\u003eShock resistance: 15 Gn for 11 ms per IEC 60068-2-7\u003c\/li\u003e\n  \u003cli\u003eMounting: Below contactor, DIN rail, or panel (with accessories)\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB\/T 14048.4, EN 50495\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS, ATEX INERIS, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eClass 10A tripping curve protects motors against sustained overload conditions per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eIntegrated phase loss sensitivity trips at 130% of Ir when one phase is lost, preventing motor burnout\u003c\/li\u003e\n  \u003cli\u003eTemperature compensation across -20...60 °C ensures consistent and accurate tripping in variable environments\u003c\/li\u003e\n  \u003cli\u003eMounts directly below TeSys D contactors (LC1D18 to LC1D38) for compact motor starter assemblies\u003c\/li\u003e\n  \u003cli\u003eRed stop button and blue reset button provide local manual control without additional accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial motor starter panels combined with TeSys D contactors\u003c\/li\u003e\n  \u003cli\u003ePump and fan motor protection in building services and HVAC systems\u003c\/li\u003e\n  \u003cli\u003eConveyor and process machinery overload protection\u003c\/li\u003e\n  \u003cli\u003eHazardous area motor installations (ATEX INERIS certified)\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore motor control systems (DNV-GL, RINA, LROS certified)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-4-1 and EN\/IEC 60947-5-1. Part of the Schneider Electric TeSys Deca range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LRD21, Schneider Electric LRD21, TeSys thermal overload relay 12-18A, motor protection relay LRD21.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065388953864,"sku":"SCHLRD21","price":23.97,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lrd21-tesys-deca-thermal-overload-relay-1218a-class-10a-859625.jpg?v=1735247312"},{"product_id":"lrd22-tesys-deca-thermal-overload-relay-16-24a-class-10a","title":"Schneider LRD22 TeSys Deca Thermal Overload Relay 16-24A","description":"\u003cp\u003eThe Schneider Electric LRD22 is a thermal overload relay from the TeSys Deca range, designed for motor protection in AC and DC circuits. With an adjustable setting of 16 to 24 A and Class 10A tripping per IEC 60947-4-1, it protects motors against overload and phase loss. Compatible with LC1D25, LC1D32, and LC1D38 contactors, it mounts directly below the contactor for compact starter assemblies.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LRD22\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys Deca (TeSys LRD)\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 16...24 A\u003c\/li\u003e\n  \u003cli\u003eTripping class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC, 0...400 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V (IEC 60947-4-1), 600 V (UL \/ CSA)\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage [Ue]: 690 V AC per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: 130% of Ir in two phases, last phase at 0\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contact: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eMounting: below contactor; DIN rail or panel plate with accessories\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 45 x 66 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.124 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...60 °C per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, ATEX INERIS, UKCA, LROS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhase loss detection trips at 130% of Ir in two phases, preventing motor burnout from single-phasing\u003c\/li\u003e\n  \u003cli\u003eMounts directly below LC1D25 \/ LC1D32 \/ LC1D38 contactors for compact, wiring-free starter assembly\u003c\/li\u003e\n  \u003cli\u003e1 NO + 1 NC auxiliary contact enables fault signalling and remote trip indication\u003c\/li\u003e\n  \u003cli\u003eTemperature compensation across -20...60 °C maintains consistent tripping accuracy in varying ambient conditions\u003c\/li\u003e\n  \u003cli\u003eFrequency range of 0...400 Hz supports both standard supplies and variable-frequency drive outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor starters in industrial automation and control panels\u003c\/li\u003e\n  \u003cli\u003eProtection of pumps, fans, compressors, and conveyor drive motors\u003c\/li\u003e\n  \u003cli\u003eMotor control centres using TeSys D contactor and overload relay assemblies\u003c\/li\u003e\n  \u003cli\u003eMarine and hazardous area installations requiring DNV-GL, BV, or ATEX INERIS certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and EN 50495. Part of the Schneider Electric TeSys Deca range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LRD22, Schneider Electric LRD22, TeSys thermal overload relay 16-24A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065389805832,"sku":"SCHLRD22","price":26.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lrd22-tesys-deca-thermal-overload-relay1624aclass-10a-825747.jpg?v=1735247312"},{"product_id":"lrd32-tesys-deca-thermal-overload-relay-23-32a-class-10a","title":"Schneider LRD32 TeSys Deca Thermal Overload Relay 23-32A","description":"\u003cp\u003eThe Schneider Electric LRD32 is a TeSys Deca differential thermal overload relay for motor protection, offering an adjustable current setting of 23 to 32 A and trip class 10A per IEC 60947-4-1. Compatible with LC1D25, LC1D32, and LC1D38 contactors, it mounts directly below the contactor and operates on AC and DC networks rated up to 690 V.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LRD32\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys LRD, TeSys Deca\u003c\/li\u003e\n  \u003cli\u003eProduct type: Differential thermal overload relay\u003c\/li\u003e\n  \u003cli\u003eRelay application: Motor protection\u003c\/li\u003e\n  \u003cli\u003eCompatible contactors: LC1D25, LC1D32, LC1D38\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eTrip class: Class 10A per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eThermal overload setting: 23...32 A\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 690 V AC per IEC 60947-4-1; 600 V per UL and CSA\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 0...400 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eTrip threshold: 1.14 +\/- 0.06 Ir per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: trip at 130% of Ir in two phases\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contact: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eMounting: below contactor, or on plate \/ DIN rail with separate accessories\u003c\/li\u003e\n  \u003cli\u003eConnection type: screw terminal blocks\u003c\/li\u003e\n  \u003cli\u003ePower circuit cable: 1.5...10 mm² (solid or flexible)\u003c\/li\u003e\n  \u003cli\u003eControl circuit cable: 1...2.5 mm²\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -60...70 °C\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 45 x 66 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.124 kg\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS, ATEX INERIS, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAdjustable current setting from 23 to 32 A provides flexible motor protection across a wide power range\u003c\/li\u003e\n  \u003cli\u003ePhase loss detection trips at 130% of Ir in two phases to guard against single-phase faults\u003c\/li\u003e\n  \u003cli\u003eTemperature compensation from -20 to 60 °C maintains consistent tripping characteristics\u003c\/li\u003e\n  \u003cli\u003e1 NO + 1 NC auxiliary contact enables signalling and control circuit integration\u003c\/li\u003e\n  \u003cli\u003eDirect mounting below TeSys D contactors enables compact motor starter assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal overload protection of three-phase electric motors\u003c\/li\u003e\n  \u003cli\u003eMotor starter assemblies combined with TeSys D contactors (LC1D25, LC1D32, LC1D38)\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation and machine control panels\u003c\/li\u003e\n  \u003cli\u003ePump, compressor, and fan motor protection in process industries\u003c\/li\u003e\n  \u003cli\u003eHVAC and building services motor control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB\/T 14048.4, and EN 50495. Part of the Schneider Electric TeSys Deca range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LRD32, Schneider Electric LRD32, TeSys thermal overload relay 23-32A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065389904136,"sku":"SCHLRD32","price":38.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lrd32-tesys-deca-thermal-overload-relay2332aclass-10a-213625.jpg?v=1735247312"},{"product_id":"la7k0064-tesys-k-thermal-overload-relays-terminal-block-la7k","title":"Schneider LA7K0064 TeSys K thermal overload relays - terminal block - LA7K","description":"\u003cp\u003eThe Schneider Electric LA7K0064 is a terminal block accessory designed for use with TeSys K thermal overload relays. Catalogued under the LA7K series, it provides a screw-type connection interface for mounting on DIN rail, enabling reliable wiring to LR2K and LR7K thermal relay units.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LA7K0064\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys\u003c\/li\u003e\n  \u003cli\u003eProduct type: Terminal block (connection accessory)\u003c\/li\u003e\n  \u003cli\u003eShort device name: LA7K\u003c\/li\u003e\n  \u003cli\u003eAccessory category: Connection accessory\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eCompatible products: LR2K, LR7K\u003c\/li\u003e\n  \u003cli\u003eConnection type: Screw terminal blocks\u003c\/li\u003e\n  \u003cli\u003eCable capacity (single solid): 1.5...4 mm² (1 or 2 cables)\u003c\/li\u003e\n  \u003cli\u003eCable capacity (flexible, without end sleeve): 0.75...4 mm² (1 or 2 cables)\u003c\/li\u003e\n  \u003cli\u003eCable capacity (flexible, with end sleeve): 0.34...2.5 mm² (1 cable), 0.34...1.5 mm² (2 cables)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 0.8 N.m (Phillips No. 2 screwdriver or 6 mm nut driver)\u003c\/li\u003e\n  \u003cli\u003eHeight: 80 mm\u003c\/li\u003e\n  \u003cli\u003eWidth: 45 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 75 mm\u003c\/li\u003e\n  \u003cli\u003eProduct weight: 0.1 kg\u003c\/li\u003e\n  \u003cli\u003eQuantity per set: 10 pieces\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eScrew terminal connections support a wide range of solid and flexible cable cross-sections from 0.34 to 4 mm²\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting for quick and secure installation in standard distribution panels\u003c\/li\u003e\n  \u003cli\u003eCompatible with LR2K and LR7K TeSys K thermal overload relay series\u003c\/li\u003e\n  \u003cli\u003eSupplied in a set of 10 units, reducing component sourcing effort for panel builders\u003c\/li\u003e\n  \u003cli\u003ePackaging uses recycled cardboard and is plastic-free, supporting Schneider Electric sustainability goals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor control panels using TeSys K thermal overload relays\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation cubicles requiring structured terminal wiring\u003c\/li\u003e\n  \u003cli\u003eMachine builder assemblies integrating LR2K or LR7K overload protection\u003c\/li\u003e\n  \u003cli\u003eDIN rail panel builds where standardised screw-type connections are required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePart of the Schneider Electric TeSys range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LA7K0064, Schneider Electric LA7K0064, TeSys K terminal block, thermal relay connection accessory.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44092373401864,"sku":"SCHLA7K0064","price":4.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/la7k0064-tesys-k-thermal-overload-relays-terminal-block-la7k-819968.jpg?v=1735244207"},{"product_id":"lad7b106-adapter-terminal-block-tesys-deca-for-separate-mounting-of-lrd01-d35-lr3d02-d35-lr97d","title":"Schneider LAD7B106 Electric LAD7B106 TeSys Adapter Terminal Block for LRD Relays","description":"\u003cp\u003eThe Schneider Electric LAD7B106 is a TeSys D thermal relay terminal block (connection block) designed as an accessory for connecting TeSys D series thermal overload relays. Compatible with LRD01-35 and LR3D01-D35 relay models, it provides screw-type terminal connections for reliable wiring in motor control applications. Supplied as a set of 10 units.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LAD7B106\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: TeSys D\u003c\/li\u003e\n  \u003cli\u003eProduct type: Terminal \/ connection block\u003c\/li\u003e\n  \u003cli\u003eDevice short name: LAD\u003c\/li\u003e\n  \u003cli\u003eCompatibility: LRD01-35, LR3D01-D35\u003c\/li\u003e\n  \u003cli\u003eAccessory category: Connection accessory\u003c\/li\u003e\n  \u003cli\u003eQuantity per set: 10 units\u003c\/li\u003e\n  \u003cli\u003eConnection type: Screw terminals for lugs\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eWidth: 45 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 80 mm\u003c\/li\u003e\n  \u003cli\u003eProduct weight: 0.1 kg\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eScrew terminal connections for lugs ensure secure, reliable wiring to TeSys D thermal overload relays\u003c\/li\u003e\n  \u003cli\u003eCompatible with the full LRD01-35 and LR3D01-D35 thermal relay range for broad application flexibility\u003c\/li\u003e\n  \u003cli\u003eCompact dimensions (45 x 85 x 80 mm) suit standard control panel installations\u003c\/li\u003e\n  \u003cli\u003eSupplied in a set of 10 units, offering convenient stock for panel builders and installers\u003c\/li\u003e\n  \u003cli\u003ePackaging uses recycled cardboard and is plastic-free, supporting Schneider Electric sustainability goals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor control centers requiring terminal connection accessories for TeSys D thermal overload relays\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation panels where LRD or LR3D series relays are installed\u003c\/li\u003e\n  \u003cli\u003eControl cabinet wiring projects needing compatible, manufacturer-approved connection blocks\u003c\/li\u003e\n  \u003cli\u003eMaintenance and replacement of wiring accessories in existing TeSys D motor protection assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePart of the Schneider Electric TeSys D range of motor control and protection components.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LAD7B106, Schneider Electric LAD7B106, TeSys D connection block, LRD relay terminal block.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44092493529352,"sku":"SCHLAD7B106","price":4.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/lad7b106-adapter-terminal-blocktesys-decafor-separate-mounting-of-lrd01d35lr3d02d35lr97d-869388.jpg?v=1735244450"},{"product_id":"1saz421201r1005-ta200du-175-thermal-overload-relay-130-175-a","title":"ABB TA200DU-175 1SAZ421201R1005 Thermal Overload Relay 130-175A","description":"\u003cp\u003eThe ABB TA200DU-175 (article 1SAZ421201R1005) is a thermal overload relay covering a current setting range of 130 to 175 A, designed to protect motors in the main circuit against overload and phase failure. It operates at trip class 10A and connects directly to block contactors. The device is an economical electromechanical protection solution suited to a wide range of motor applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: TA200DU-175\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ421201R1005\u003c\/li\u003e\n\u003cli\u003eEAN: 4013614286056\u003c\/li\u003e\n\u003cli\u003eType: Thermal overload relay\u003c\/li\u003e\n\u003cli\u003eCurrent setting range: 130 - 175 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10A\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO\u003c\/li\u003e\n\u003cli\u003eReset: Automatic or manual (selectable)\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to block contactors; single mounting kits available as accessory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrip class 10A provides defined overload response timing suited to standard motor starting conditions\u003c\/li\u003e\n\u003cli\u003eTemperature compensation maintains accurate tripping performance across varying ambient temperatures\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset gives flexibility for different installation and maintenance requirements\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism ensures the relay cannot be held in the closed position during a trip event\u003c\/li\u003e\n\u003cli\u003eSTOP and Test function allows routine functional checks without disconnecting the relay from the circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverload and phase failure protection for three-phase motors in industrial installations\u003c\/li\u003e\n\u003cli\u003eMain circuit protection in motor control centers and distribution panels\u003c\/li\u003e\n\u003cli\u003eMotor starter assemblies using ABB block contactors\u003c\/li\u003e\n\u003cli\u003eProtection of pumps, fans, compressors, and similar motor-driven equipment in the 130-175 A range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: ABB TA200DU-175, TA200DU-175 1SAZ421201R1005, thermal overload relay 130-175 A, motor protection relay 175 A, overload protection relay 130 A.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750008877320,"sku":"ABB1SAZ421201R1005","price":86.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz421201r1005-ta200du-175-thermal-overload-relay-130-175-a-370648.jpg?v=1735224739"},{"product_id":"1saz321201r2004-ta75du-52m-thermal-overload-relays","title":"ABB TA75DU-52M 1SAZ321201R2004 Thermal Overload Relay","description":"\u003cp\u003eThe ABB TA75DU-52M (article 1SAZ321201R2004) is a thermal overload relay with a current setting range of 36.0-52.0 A and trip class 10A. It acts as an electromechanical protection device in the main circuit, guarding motors against damage caused by overload conditions or phase failure. The relay mounts directly to block contactors for a compact, integrated installation.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: TA75DU-52M\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ321201R2004\u003c\/li\u003e\n\u003cli\u003eEAN: 4013614482656\u003c\/li\u003e\n\u003cli\u003eType: Thermal overload relay\u003c\/li\u003e\n\u003cli\u003eCurrent setting range: 36.0-52.0 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10A\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC (normally closed)\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO (normally open)\u003c\/li\u003e\n\u003cli\u003eReset mode: Automatic or manual, selectable\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to block contactors; single mounting kits available as accessory\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eElectromechanical motor protection against both overload and phase failure in the main circuit\u003c\/li\u003e\n\u003cli\u003eTrip class 10A provides a fast tripping response appropriate for standard motor protection\u003c\/li\u003e\n\u003cli\u003eTemperature compensation maintains consistent trip behaviour across changing ambient conditions\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset allows flexible fault recovery to suit the application\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism prevents the relay from being held closed during a fault, so protective action cannot be defeated\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMotor overload protection in industrial control panels and motor control centres\u003c\/li\u003e\n\u003cli\u003ePhase-failure detection in three-phase motor installations\u003c\/li\u003e\n\u003cli\u003eProtection of pumps, fans, compressors, and conveyor drives\u003c\/li\u003e\n\u003cli\u003eContactor-based direct-on-line motor starters in machinery and building services\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB TA75DU-52M, TA75DU-52M 1SAZ321201R2004, ABB thermal overload relay 52A, motor overload relay 36-52A, 1SAZ321201R2004.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750016479496,"sku":"ABB1SAZ321201R2004","price":31.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz321201r2004-ta75du-52m-thermal-overload-relays-837501.jpg?v=1735224747"},{"product_id":"1saz721201r1051-tf42-24-thermal-overload-relay-20-24-a","title":"ABB TF42-24 1SAZ721201R1051 Thermal Overload Relay 20-24A","description":"\u003cp\u003eThe ABB TF42-24 (article 1SAZ721201R1051) is a thermal overload relay with a current setting range of 20 - 24 A, built for main circuit protection in motor applications. As an electromechanical device, it safeguards motors against overload conditions and phase failure, operating at trip class 10. It mounts directly to block contactors and is complemented by optional single mounting kits for standalone installation.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: TF42-24\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ721201R1051\u003c\/li\u003e\n\u003cli\u003eEAN: 4013614398155\u003c\/li\u003e\n\u003cli\u003eType: Thermal Overload Relay\u003c\/li\u003e\n\u003cli\u003eCurrent setting range: 20 - 24 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO\u003c\/li\u003e\n\u003cli\u003eReset mode: Automatic or manual (selectable)\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to block contactors; single mounting kits available as accessory\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePhase failure detection halts the motor when one phase is lost, preventing winding damage\u003c\/li\u003e\n\u003cli\u003eTemperature compensation adjusts the trip threshold to match ambient conditions, avoiding unnecessary shutdowns\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism ensures the relay always trips on a genuine fault, even when the reset button is held\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset lets the installer choose the appropriate restart behavior for each application\u003c\/li\u003e\n\u003cli\u003eIntegrated STOP function and trip indication simplify fault diagnosis and reduce additional wiring in the panel\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMotor starter circuits in industrial control cabinets\u003c\/li\u003e\n\u003cli\u003eOverload protection for pumps, fans, and compressors\u003c\/li\u003e\n\u003cli\u003eConveyor and machine drive panels using block contactor assemblies\u003c\/li\u003e\n\u003cli\u003eHVAC and water treatment systems requiring dependable motor protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB TF42-24, TF42-24 1SAZ721201R1051, thermal overload relay 20-24A, motor protection relay 1SAZ721201R1051, ABB overload relay TF42.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750023229704,"sku":"ABB1SAZ721201R1051","price":19.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz721201r1051-tf42-24-thermal-overload-relay-20-24-a-917941.jpg?v=1735224750"},{"product_id":"1saz721201r1052-tf42-29-thermal-overload-relay-24-29-a","title":"ABB TF42-29 1SAZ721201R1052 Thermal Overload Relay 24-29A","description":"\u003cp\u003eThe ABB TF42-29 (article 1SAZ721201R1052) is a thermal overload relay for motor protection in the main circuit. It covers a current setting range of 24 to 29 A and operates at trip class 10, protecting motors against overload and phase failure. The relay connects directly to block contactors, with single mounting kits available as an accessory for standalone installation.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: TF42-29\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ721201R1052\u003c\/li\u003e\n\u003cli\u003eEAN: 4016779764988\u003c\/li\u003e\n\u003cli\u003eCurrent setting range: 24 - 29 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO\u003c\/li\u003e\n\u003cli\u003eReset mode: Automatic or manual (selectable)\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to block contactors; single mounting kits available as accessory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrip class 10 delivers fast disconnection when a motor draws excessive current during overload\u003c\/li\u003e\n\u003cli\u003ePhase failure detection guards motors from damage caused by loss of a supply phase\u003c\/li\u003e\n\u003cli\u003eTemperature compensation maintains consistent tripping behaviour across varying ambient temperatures\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset gives the installer direct control over fault-recovery behaviour\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism with STOP function and trip indication supports safe fault response and rapid diagnosis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverload and phase failure protection for three-phase motors in industrial equipment\u003c\/li\u003e\n\u003cli\u003eMotor control centers using block contactors requiring coverage in the 24 - 29 A range\u003c\/li\u003e\n\u003cli\u003ePumps, compressors, and conveyor drives where motor protection is required\u003c\/li\u003e\n\u003cli\u003eLight to medium industrial machinery calling for an economic electromechanical protection device\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: ABB TF42-29, TF42-29 1SAZ721201R1052, thermal overload relay 29 A, motor overload relay 24-29A, TF42 series overload relay.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750023262472,"sku":"ABB1SAZ721201R1052","price":22.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz721201r1052-tf42-29-thermal-overload-relay-24-29-a-356863.jpg?v=1735224747"},{"product_id":"1saz721201r1053-tf42-35-thermal-overload-relay-29-35-a","title":"ABB TF42-35 1SAZ721201R1053 Thermal Overload Relay 29-35A","description":"\u003cp\u003eABB TF42-35 (article 1SAZ721201R1053) is a thermal overload relay with a current setting range of 29 to 35 A, designed to deliver electromechanical overload and phase failure protection for motor main circuits. It operates at trip class 10 and mounts directly onto block contactors, offering a compact and economical motor protection solution.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: TF42-35\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ721201R1053\u003c\/li\u003e\n\u003cli\u003eEAN: 4013614398162\u003c\/li\u003e\n\u003cli\u003eType: Thermal overload relay\u003c\/li\u003e\n\u003cli\u003eCurrent setting range: 29 - 35 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO\u003c\/li\u003e\n\u003cli\u003eReset mode: Automatic or manual (selectable)\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to block contactors; single mounting kits available as accessory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrip class 10 delivers fast protection when motors are subjected to sustained overload conditions\u003c\/li\u003e\n\u003cli\u003ePhase failure detection prevents motor damage caused by single-phasing in three-phase circuits\u003c\/li\u003e\n\u003cli\u003eTemperature compensation keeps tripping behaviour consistent across varying ambient temperatures\u003c\/li\u003e\n\u003cli\u003eAutomatic or manual reset is selectable, allowing the operator to choose the recovery mode that suits the application\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism, integrated STOP function, and visual trip indication support safe operation and rapid fault diagnosis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverload protection for three-phase induction motors in industrial machinery and production lines\u003c\/li\u003e\n\u003cli\u003eMotor starter assemblies built with ABB block contactors\u003c\/li\u003e\n\u003cli\u003eControl panel motor protection circuits requiring integrated phase failure detection\u003c\/li\u003e\n\u003cli\u003ePump, fan, and compressor drive protection in building services and process plant installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: ABB TF42-35, TF42-35 1SAZ721201R1053, thermal overload relay 29-35 A, motor overload relay 35 A, electromechanical motor protection relay.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750023328008,"sku":"ABB1SAZ721201R1053","price":34.42,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz721201r1053-tf42-35-thermal-overload-relay-29-35-a-452441.jpg?v=1735224746"},{"product_id":"1saz721201r1049-tf42-20-thermal-overload-relay-16-20-a","title":"ABB TF42-20 1SAZ721201R1049 Thermal Overload Relay 16-20A","description":"\u003cp\u003eThe ABB TF42-20 (article 1SAZ721201R1049) is a thermal overload relay with a current setting range of 16 to 20 A. It is an electromechanical protection device for the main circuit, designed to guard motors against overload conditions and phase failure. The relay mounts directly onto block contactors, simplifying integration into motor starter configurations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: TF42-20\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ721201R1049\u003c\/li\u003e\n\u003cli\u003eEAN: 4016779764971\u003c\/li\u003e\n\u003cli\u003eProduct type: Thermal overload relay\u003c\/li\u003e\n\u003cli\u003eCurrent setting range: 16 to 20 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC (normally closed)\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO (normally open)\u003c\/li\u003e\n\u003cli\u003eReset mode: Automatic or manual, selectable\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to block contactors; single mounting kits available as accessory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrip class 10 rating for defined motor overload protection response\u003c\/li\u003e\n\u003cli\u003ePhase failure detection protects motors from the damage caused by single-phase operation\u003c\/li\u003e\n\u003cli\u003eTemperature compensation maintains consistent tripping behavior across varying ambient conditions\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset lets the installer match relay behavior to the application\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism with STOP function and trip indication prevents the relay from being held in during a fault and provides clear fault status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMotor overload protection in the 16 to 20 A range for industrial machinery\u003c\/li\u003e\n\u003cli\u003eDirect-on-line and reversing motor starter assemblies built with block contactors\u003c\/li\u003e\n\u003cli\u003ePump, fan, and compressor motor circuits requiring automatic or manual reset capability\u003c\/li\u003e\n\u003cli\u003eConveyor and machine tool motor control panels needing overload and phase failure monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: ABB TF42-20, TF42-20 1SAZ721201R1049, thermal overload relay 16-20 A, ABB motor protection relay, TF42-20 overload relay.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750023753992,"sku":"ABB1SAZ721201R1049","price":25.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz721201r1049-tf42-20-thermal-overload-relay-16-20-a-766758.jpg?v=1735224742"},{"product_id":"1saz721201r1033-tf42-3-1-thermal-overload-relay-2-3-3-1-a","title":"ABB TF42-3.1 1SAZ721201R1033 Thermal Overload Relay 2.3-3.1A","description":"\u003cp\u003eThe ABB TF42-3.1 (article 1SAZ721201R1033) is a thermal overload relay for main circuit motor protection. It covers a current setting range of 2.3 - 3.1 A with trip class 10, and mounts directly to block contactors for a compact, economical installation. It guards motors against overload conditions and phase failure through electromechanical operation.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: TF42-3.1\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ721201R1033\u003c\/li\u003e\n\u003cli\u003eEAN: 4013614398087\u003c\/li\u003e\n\u003cli\u003eType: Thermal overload relay\u003c\/li\u003e\n\u003cli\u003eCurrent setting range: 2.3 - 3.1 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO\u003c\/li\u003e\n\u003cli\u003eReset mode: Automatic or manual, selectable\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to block contactors; single mounting kits available as accessory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrip class 10 ensures fast disconnection when motor current exceeds the set threshold\u003c\/li\u003e\n\u003cli\u003ePhase failure detection cuts power before single-phasing causes motor winding damage\u003c\/li\u003e\n\u003cli\u003eTemperature compensation keeps tripping behavior consistent regardless of ambient temperature changes\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset gives operators control over restart behavior after a trip\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism, STOP function, and built-in trip indication support safe and transparent operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverload protection for small motors in industrial machinery and automation systems\u003c\/li\u003e\n\u003cli\u003eSafeguarding pump and fan motor circuits rated within the 2.3 - 3.1 A range\u003c\/li\u003e\n\u003cli\u003eDirect-mount protection in motor control panels equipped with block contactors\u003c\/li\u003e\n\u003cli\u003eLow-current motor circuits where phase failure detection is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: ABB TF42-3.1, TF42-3.1 1SAZ721201R1033, ABB thermal overload relay 2.3-3.1 A, ABB motor protection relay, 1SAZ721201R1033.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750024081672,"sku":"ABB1SAZ721201R1033","price":16.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz721201r1033-tf42-31-thermal-overload-relay-23-31-a-390584.jpg?v=1735224746"},{"product_id":"1saz721201r1035-tf42-4-2-thermal-overload-relay-3-1-4-2-a","title":"ABB TF42-4.2 1SAZ721201R1035 Thermal Overload Relay 3.1-4.2A","description":"\u003cp\u003eABB TF42-4.2 (article 1SAZ721201R1035) is a thermal overload relay with a current setting range of 3.1 A to 4.2 A, built to protect motors in the main circuit against overload conditions and phase failure. It uses an electromechanical operating principle and delivers trip class 10 performance, mounting directly onto ABB block contactors for a compact motor starter assembly.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: TF42-4.2\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ721201R1035\u003c\/li\u003e\n\u003cli\u003eEAN: 4013614398094\u003c\/li\u003e\n\u003cli\u003eType: Thermal overload relay\u003c\/li\u003e\n\u003cli\u003eCurrent setting range: 3.1 A - 4.2 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO\u003c\/li\u003e\n\u003cli\u003eReset mode: Automatic or manual (selectable)\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to block contactors (single mounting kits available as accessory)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTrip class 10 performance delivers fast disconnection of the motor circuit when overload or phase failure is detected\u003c\/li\u003e\n\u003cli\u003eTemperature compensation keeps tripping behavior consistent across varying ambient conditions\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset gives operators direct control over circuit restoration after a trip event\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism and STOP function prevent the relay from being held in the closed position during a fault condition\u003c\/li\u003e\n\u003cli\u003eBuilt-in trip indication gives a clear visual signal that the relay has operated, simplifying fault diagnosis on the panel\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMotor protection in industrial machinery, pumps, and conveyor drives\u003c\/li\u003e\n\u003cli\u003eDirect integration with ABB block contactors in motor starter assemblies\u003c\/li\u003e\n\u003cli\u003eControl panel circuit protection for small three-phase motors in manufacturing environments\u003c\/li\u003e\n\u003cli\u003eMotor circuit protection in HVAC and building services installations\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB TF42-4.2, TF42-4.2 1SAZ721201R1035, thermal overload relay 3.1-4.2 A, ABB motor protection relay, TF42 overload relay.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750024114440,"sku":"ABB1SAZ721201R1035","price":16.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz721201r1035-tf42-42-thermal-overload-relay-31-42-a-977985.jpg?v=1735224742"},{"product_id":"1saz721201r1038-tf42-5-7-thermal-overload-relay-4-2-5-7-a","title":"ABB TF42-5.7 1SAZ721201R1038 Thermal Overload Relay 4.2-5.7A","description":"\u003cp\u003eThe ABB TF42-5.7 (article 1SAZ721201R1038) is a thermal overload relay with a current setting range of 4.2 to 5.7 A and trip class 10. It serves as an electromechanical protection device in the main circuit, shielding motors from damage caused by overload or phase failure. The relay connects directly to block contactors, and single mounting kits are available as an accessory for standalone installation.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: TF42-5.7\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ721201R1038\u003c\/li\u003e\n\u003cli\u003eEAN: 4013614398100\u003c\/li\u003e\n\u003cli\u003eCurrent setting range: 4.2 - 5.7 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO\u003c\/li\u003e\n\u003cli\u003eReset mode: Automatic or manual (selectable)\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to block contactors\u003c\/li\u003e\n\u003cli\u003eAccessory: Single mounting kits available\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTrip class 10 delivers fast motor protection under sustained overload conditions\u003c\/li\u003e\n\u003cli\u003ePhase failure detection halts the motor before damage occurs when a supply phase is lost\u003c\/li\u003e\n\u003cli\u003eTemperature compensation maintains consistent tripping behaviour across varying ambient temperatures\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset allows the relay to match the restart requirements of the application\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism and STOP function ensure the protective trip cannot be overridden\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProtection of three-phase motors in industrial control panels and machinery\u003c\/li\u003e\n\u003cli\u003eMotor starter assemblies built around block contactors\u003c\/li\u003e\n\u003cli\u003ePump, fan, and conveyor motor protection in light industrial installations\u003c\/li\u003e\n\u003cli\u003eDirect-on-line starter circuits requiring overload and phase loss protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB TF42-5.7, TF42-5.7 1SAZ721201R1038, thermal overload relay 4.2-5.7 A, motor overload relay trip class 10, ABB 1SAZ721201R1038.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750024147208,"sku":"ABB1SAZ721201R1038","price":16.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz721201r1038-tf42-57-thermal-overload-relay-42-57-a-278456.jpg?v=1735224739"},{"product_id":"1saz721201r1040-tf42-7-6-thermal-overload-relay-5-7-7-6-a","title":"ABB TF42-7.6 1SAZ721201R1040 Thermal Overload Relay 5.7-7.6A","description":"\u003cp\u003eThe ABB TF42-7.6 (article 1SAZ721201R1040) is a thermal overload relay that provides electromechanical motor protection against overload and phase failure. It covers a current setting range of 5.7 to 7.6 A and operates to trip class 10. The relay mounts directly onto block contactors, making it a compact and economical choice for main circuit motor protection.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: TF42-7.6\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ721201R1040\u003c\/li\u003e\n\u003cli\u003eEAN: 4013614398117\u003c\/li\u003e\n\u003cli\u003eCurrent setting range: 5.7 - 7.6 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO\u003c\/li\u003e\n\u003cli\u003eReset mode: Automatic or manual (selectable)\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to block contactors; single mounting kits available as accessory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrip class 10 delivers fast response to overload conditions, limiting motor damage\u003c\/li\u003e\n\u003cli\u003ePhase failure detection guards against the heat and stress caused by single-phasing\u003c\/li\u003e\n\u003cli\u003eTemperature compensation keeps tripping behaviour consistent across varying ambient conditions\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset adapts to different restart and safety requirements\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism, STOP function, and visual trip indication support safe operation and quick fault diagnosis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMotor starter protection in industrial control panels and switchgear assemblies\u003c\/li\u003e\n\u003cli\u003ePump and fan circuits requiring dependable overload protection\u003c\/li\u003e\n\u003cli\u003eConveyor and machine tool applications built around block contactor assemblies\u003c\/li\u003e\n\u003cli\u003eDirect-on-line and reversing starter configurations within the 5.7 - 7.6 A current range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: ABB TF42-7.6, TF42-7.6 1SAZ721201R1040, thermal overload relay 5.7-7.6 A, motor overload relay, electromechanical overload relay.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750024179976,"sku":"ABB1SAZ721201R1040","price":16.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz721201r1040-tf42-76-thermal-overload-relay-57-76-a-581423.jpg?v=1735224749"},{"product_id":"1saz721201r1043-tf42-10-thermal-overload-relay-7-6-10-a","title":"ABB TF42-10 1SAZ721201R1043 Thermal Overload Relay 7.6-10A","description":"\u003cp\u003eThe ABB TF42-10 (article 1SAZ721201R1043) is a thermal overload relay providing electromechanical protection for motor main circuits. It defends motors against overload conditions and phase failure, with a current setting range of 7.6 to 10 A and trip class 10.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: TF42-10\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ721201R1043\u003c\/li\u003e\n\u003cli\u003eEAN: 4013614398124\u003c\/li\u003e\n\u003cli\u003eCurrent setting range: 7.6 - 10 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC (normally closed)\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO (normally open)\u003c\/li\u003e\n\u003cli\u003eReset mode: Automatic or manual, selectable\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to block contactors; single mounting kits available as accessory\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGuards motors against damage from overload conditions and phase failure\u003c\/li\u003e\n\u003cli\u003eTemperature compensation maintains consistent tripping behaviour across varying ambient conditions\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism prevents the protective function from being bypassed during a fault\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset provides flexibility for system restart procedures\u003c\/li\u003e\n\u003cli\u003eSTOP function and trip indication support swift fault identification and safe shutdown\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMotor starter assemblies in industrial control panels\u003c\/li\u003e\n\u003cli\u003ePump and fan motor protection in building services and process plant\u003c\/li\u003e\n\u003cli\u003eConveyor and compressor motor circuits requiring overload protection\u003c\/li\u003e\n\u003cli\u003eDirect mounting on ABB block contactors where compact installation is required\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB TF42-10, TF42-10 1SAZ721201R1043, thermal overload relay 7.6-10 A, motor overload relay TF42, 1SAZ721201R1043.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750024212744,"sku":"ABB1SAZ721201R1043","price":22.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz721201r1043-tf42-10-thermal-overload-relay-76-10-a-909939.jpg?v=1735224749"},{"product_id":"1saz721201r1045-tf42-13-thermal-overload-relay-10-13-a","title":"ABB TF42-13 1SAZ721201R1045 Thermal Overload Relay 10-13A","description":"\u003cp\u003eABB TF42-13 (article 1SAZ721201R1045) is an economical electromechanical thermal overload relay for motor main circuit protection. It provides protection against overload and phase failure events across a current range of 10 - 13 A with trip class 10. The relay mounts directly onto block contactors, making it a compact fit for motor starter assemblies.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: TF42-13\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ721201R1045\u003c\/li\u003e\n\u003cli\u003eEAN: 4013614398131\u003c\/li\u003e\n\u003cli\u003eType: Thermal overload relay\u003c\/li\u003e\n\u003cli\u003eCurrent range: 10 - 13 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to block contactors\u003c\/li\u003e\n\u003cli\u003eAccessory: Single mounting kits available separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTemperature compensation maintains consistent tripping behavior across varying ambient conditions\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset gives flexibility in fault-recovery handling\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism prevents the relay from being held closed during an active fault\u003c\/li\u003e\n\u003cli\u003eIntegrated STOP function and trip indication simplify fault diagnosis and controlled shutdown\u003c\/li\u003e\n\u003cli\u003ePhase failure detection guards motor windings against single-phasing damage\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOverload and phase failure protection for three-phase motors in industrial machinery\u003c\/li\u003e\n\u003cli\u003eMotor starter assemblies built around block contactors in control panels\u003c\/li\u003e\n\u003cli\u003ePump, fan, and compressor drive protection circuits\u003c\/li\u003e\n\u003cli\u003eConveyor and production line motor control installations\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB TF42-13, TF42-13 1SAZ721201R1045, ABB thermal overload relay 10-13 A, 1SAZ721201R1045, ABB TF42 overload relay.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750024278280,"sku":"ABB1SAZ721201R1045","price":23.84,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz721201r1045-tf42-13-thermal-overload-relay-10-13-a-408767.jpg?v=1735224739"},{"product_id":"1saz721201r1047-tf42-16-thermal-overload-relay-13-16-a","title":"ABB TF42-16 1SAZ721201R1047 Thermal Overload Relay 13-16A","description":"\u003cp\u003eABB TF42-16 (article 1SAZ721201R1047) is a thermal overload relay covering a current range of 13 - 16 A. Designed as an electromechanical protection device for the main circuit, it guards motors against overload and phase failure. The relay operates at trip class 10, making it suitable for standard motor protection applications.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: TF42-16\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ721201R1047\u003c\/li\u003e\n\u003cli\u003eEAN: 4013614398148\u003c\/li\u003e\n\u003cli\u003eType: Thermal Overload Relay\u003c\/li\u003e\n\u003cli\u003eCurrent range: 13 - 16 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO\u003c\/li\u003e\n\u003cli\u003eReset mode: Automatic or manual (selectable)\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to block contactors\u003c\/li\u003e\n\u003cli\u003eAccessory: Single mounting kits available separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTrip class 10 operation delivers fast motor protection in overload and phase failure events\u003c\/li\u003e\n\u003cli\u003eTemperature compensation maintains consistent tripping behavior under varying ambient conditions\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset gives flexibility for different restart procedures\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism with STOP function and visual trip indication supports safe maintenance and fault diagnosis\u003c\/li\u003e\n\u003cli\u003eDirect connection to block contactors reduces wiring effort; single mounting kits available as an accessory for standalone installation\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMotor starter protection in industrial machinery and control panels\u003c\/li\u003e\n\u003cli\u003eThree-phase motor circuits where phase failure detection is required\u003c\/li\u003e\n\u003cli\u003ePump and conveyor drive overload protection\u003c\/li\u003e\n\u003cli\u003eCompact motor control centers and distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB TF42-16, TF42-16 1SAZ721201R1047, ABB 1SAZ721201R1047, thermal overload relay 13-16 A, motor protection relay.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750024311048,"sku":"ABB1SAZ721201R1047","price":17.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz721201r1047-tf42-16-thermal-overload-relay-13-16-a-716500.jpg?v=1735224739"},{"product_id":"1saz811201r1004-abb-tf65-47-thermal-overload-relay-36-47a","title":"ABB TF65-47 1SAZ811201R1004 Thermal Overload Relay","description":"\u003cp\u003eThe ABB TF65-47 (article 1SAZ811201R1004) is a thermal overload relay with a current setting range of 36 to 47 A. It serves as an electromechanical protection device for motor main circuits, guarding against overload conditions and phase failure. The relay operates at trip class 10, enabling fast and dependable disconnection when a fault is detected.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: TF65-47\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ811201R1004\u003c\/li\u003e\n\u003cli\u003eEAN: 4013614482946\u003c\/li\u003e\n\u003cli\u003eType: Thermal overload relay\u003c\/li\u003e\n\u003cli\u003eCurrent range: 36 - 47 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC (normally closed)\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO (normally open)\u003c\/li\u003e\n\u003cli\u003eReset mode: Automatic or manual - selectable\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to block contactors; single mounting kits available as accessory\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTemperature compensation maintains accurate trip response across varying ambient conditions\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset gives flexibility in fault recovery procedures\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism prevents the relay from being held closed during a fault condition\u003c\/li\u003e\n\u003cli\u003eSTOP function allows manual interruption of the circuit independently of the overload condition\u003c\/li\u003e\n\u003cli\u003eTrip indication provides immediate visual feedback when a fault has caused disconnection\u003c\/li\u003e\n\u003cli\u003ePhase failure detection protects motor windings from damage caused by loss of a supply phase\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOverload and phase failure protection for three-phase motors in industrial installations\u003c\/li\u003e\n\u003cli\u003eMotor starter assemblies built around block contactors\u003c\/li\u003e\n\u003cli\u003eProtection of pump and fan motors in process and HVAC systems\u003c\/li\u003e\n\u003cli\u003eConveyor, compressor, and machine drive motor protection circuits\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB TF65-47, TF65-47 1SAZ811201R1004, thermal overload relay 36-47 A, motor overload relay 47 A, electromechanical motor protection relay.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51155111313672,"sku":"ABB1SAZ811201R1004","price":38.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz811201r1004-abb-tf65-47-thermal-overload-relay-36-47a-4128037.jpg?v=1757425428"},{"product_id":"1saz421201r1004-abb-ta200du-150-thermal-overload-relay","title":"ABB TA200DU-150 1SAZ421201R1004 Thermal Overload Relay","description":"\u003cp\u003eABB TA200DU-150 (article 1SAZ421201R1004) is a thermal overload relay with a current setting range of 110 - 150 A. It serves as an electromechanical protection device for the main circuit, shielding motors from overload conditions and phase failure. The relay carries trip class 10A, enabling fast response to abnormal current levels before damage occurs.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: TA200DU-150\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ421201R1004\u003c\/li\u003e\n\u003cli\u003eEAN: 4013614286049\u003c\/li\u003e\n\u003cli\u003eType: Thermal overload relay\u003c\/li\u003e\n\u003cli\u003eCurrent setting range: 110 - 150 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10A\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC (normally closed)\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO (normally open)\u003c\/li\u003e\n\u003cli\u003eReset mode: Automatic or manual, selectable\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to block contactors; single mounting kits available as accessory\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTrip class 10A provides fast tripping response to protect motors from prolonged overload currents\u003c\/li\u003e\n\u003cli\u003ePhase failure detection guards against motor damage caused by a missing or unbalanced supply phase\u003c\/li\u003e\n\u003cli\u003eTemperature compensation keeps trip characteristics consistent regardless of changes in ambient temperature\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism prevents the relay from being held in the closed position during a fault\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset allows the system recovery mode to be matched to the application requirements\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOverload protection of large three-phase motors in industrial drive systems\u003c\/li\u003e\n\u003cli\u003eMotor protection in heavy-duty pump and fan installations\u003c\/li\u003e\n\u003cli\u003eUse within motor control centres alongside ABB block contactors\u003c\/li\u003e\n\u003cli\u003eProtection of high-current motors in process and manufacturing plant\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB TA200DU-150, TA200DU-150 1SAZ421201R1004, ABB 1SAZ421201R1004, thermal overload relay 110-150 A, ABB motor overload relay.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52461597982984,"sku":"ABB1SAZ421201R1004","price":100.79,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz421201r1004-abb-ta200du-150-thermal-overload-relay-7011952.jpg?v=1758365064"},{"product_id":"lrd365l-schneider-electric-thermal-overload-relay-tesys-deca-48-65a-690v-class-20","title":"Schneider LRD365L Thermal Overload Relay, TeSys Deca, 48-65A 690V class 20","description":"\u003cp\u003eThe Schneider Electric LRD365L is a TeSys Deca thermal differential overload relay for motor protection. It covers an adjustable range of 48 to 65 A at 690 V AC, with a class 20 trip characteristic and direct mounting below LC1D50A or LC1D65A contactors.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: LRD365L\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries: TeSys Deca\u003c\/li\u003e\n  \u003cli\u003eProduct type: Thermal differential overload relay\u003c\/li\u003e\n  \u003cli\u003eRelay application: Motor protection\u003c\/li\u003e\n  \u003cli\u003eCompatible contactors: LC1D50A, LC1D65A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTrip class: Class 20 per IEC 60947-4-1\u003c\/li\u003e\n  \u003cli\u003eOverload adjustment range: 48...65 A\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 690 V AC, 0...400 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V (IEC), 600 V (UL\/CSA)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contact: 1 NO + 1 NC\u003c\/li\u003e\n  \u003cli\u003eMounting: below contactor; panel or DIN rail with accessory\u003c\/li\u003e\n  \u003cli\u003ePower circuit connection: EverLink BTR screw terminal, 1...35 mm²\u003c\/li\u003e\n  \u003cli\u003eControl circuit connection: screw terminal blocks, 1...2.5 mm²\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 55 x 70 x 123 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -20...60 °C\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC, UL, CSA, CCC, EAC, DNV-GL, RMRS, EU-RO MR, LROS, UKCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eClass 20 trip characteristic suits motors with extended acceleration times\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitivity: trips at 130% of Ir when one phase drops to zero\u003c\/li\u003e\n  \u003cli\u003eRed stop button and blue reset button for manual operation\u003c\/li\u003e\n  \u003cli\u003eEverLink BTR power terminals accept cables from 1 to 35 mm²\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor protection in industrial automation and control panels\u003c\/li\u003e\n  \u003cli\u003eDrives for pumps, fans, and compressors with long start sequences\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore installations requiring DNV-GL or LROS certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-4-1 and EN\/IEC 60947-5-1. Part of the Schneider Electric TeSys Deca range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider LRD365L, Schneider Electric LRD365L, thermal overload relay, motor overload relay.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53437837082888,"sku":"SCHLRD365L","price":64.21,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/schneider-lrd365l-thermal-overload-relay-tesys-deca-48-65a-690v-class-20-2731357.jpg?v=1779038118"},{"product_id":"1saz711201r1035-abb-t16-4-2-thermal-overload-relay-3-1-4-2a","title":"1SAZ711201R1035 ABB T16-4.2 Thermal Overload Relay 3.1-4.2A","description":"\u003cp\u003eThe ABB T16-4.2 (article 1SAZ711201R1035) is a thermal overload relay providing electromechanical protection for motor main circuits. Covering a current setting range of 3.1 to 4.2 A with trip class 10, it guards motors against overload conditions and phase failure. The device connects directly to mini contactors or block contactors, making it a compact and economical protection solution.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: T16-4.2\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ711201R1035\u003c\/li\u003e\n\u003cli\u003eEAN: 4013614397929\u003c\/li\u003e\n\u003cli\u003eCurrent setting range: 3.1 - 4.2 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO\u003c\/li\u003e\n\u003cli\u003eReset mode: automatic or manual, selectable\u003c\/li\u003e\n\u003cli\u003eMounting: direct connection to mini contactors or block contactors\u003c\/li\u003e\n\u003cli\u003eMounting kit: single mounting kits available as accessory\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProtects motors against overload and phase failure for dependable operation\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset gives flexibility to suit the application\u003c\/li\u003e\n\u003cli\u003eTemperature compensation maintains consistent trip behaviour across varying ambient temperatures\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism with STOP function prevents bypassing of the protection during a fault\u003c\/li\u003e\n\u003cli\u003eTrip indication provides immediate visual confirmation of a tripped condition for faster fault diagnosis\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMotor protection in direct-on-line starters built around mini or block contactors\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels requiring compact, economical overload protection\u003c\/li\u003e\n\u003cli\u003eMachine control circuits where phase failure detection is required\u003c\/li\u003e\n\u003cli\u003eSmall motor drive assemblies where a low current range of 3.1 - 4.2 A is needed\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB T16-4.2, T16-4.2 1SAZ711201R1035, 1SAZ711201R1035, thermal overload relay 3.1-4.2 A, motor overload relay ABB.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56097962950920,"sku":"ABB1SAZ711201R1035","price":17.74,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz711201r1035-abb-t16-42-thermal-overload-relay-31-42a-3958873.jpg?v=1775523388"},{"product_id":"1saz711201r1021-abb-t16-0-74-thermal-overload-relay-0-55-0-74a","title":"1SAZ711201R1021 ABB T16-0.74 Thermal Overload Relay 0.55-0.74A","description":"\u003cp\u003eABB T16-0.74 (article 1SAZ711201R1021) is a thermal overload relay with a current setting range of 0.55 to 0.74 A. It acts as an electromechanical protection device for motor main circuits, guarding against overload and phase failure at trip class 10. The relay connects directly to mini contactors or block contactors, with single mounting kits available as an accessory for standalone installation.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: T16-0.74\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ711201R1021\u003c\/li\u003e\n\u003cli\u003eEAN: 4013614397868\u003c\/li\u003e\n\u003cli\u003eType: Thermal overload relay\u003c\/li\u003e\n\u003cli\u003eCurrent setting range: 0.55 - 0.74 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC (normally closed)\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO (normally open)\u003c\/li\u003e\n\u003cli\u003eReset mode: Automatic or manual (selectable)\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to mini contactors or block contactors\u003c\/li\u003e\n\u003cli\u003eAccessory: Single mounting kits available for independent installation\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTrip class 10 response delivers fast motor protection against both overload conditions and phase failure\u003c\/li\u003e\n\u003cli\u003eTemperature compensation maintains consistent tripping behaviour across a range of ambient temperatures\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset allows the installer to choose how the system recovers after a fault\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism prevents the relay from being held in the closed position during an active fault\u003c\/li\u003e\n\u003cli\u003eSTOP function combined with trip indication enables local shutdown and clear visual fault signalling\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOverload and phase-loss protection for small motors in low-voltage control panels\u003c\/li\u003e\n\u003cli\u003eStarter assemblies built around mini contactors or block contactors\u003c\/li\u003e\n\u003cli\u003eProtection of pump and fan motors in industrial and building service installations\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose motor protection applications requiring trip class 10 characteristics\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB T16-0.74, T16-0.74 1SAZ711201R1021, ABB thermal overload relay 0.55-0.74 A, 1SAZ711201R1021, ABB motor overload relay T16.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56098803515656,"sku":"ABB1SAZ711201R1021","price":17.74,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz711201r1021-abb-t16-074-thermal-overload-relay-055-074a-6189715.jpg?v=1775523387"},{"product_id":"1saz711201r1014-abb-t16-0-41-thermal-overload-relay-0-31-0-41-a","title":"1SAZ711201R1014 ABB T16-0.41 Thermal Overload Relay 0.31-0.41A","description":"\u003cp\u003eThe ABB T16-0.41 (article 1SAZ711201R1014) is a thermal overload relay designed for motor protection in the main circuit. It guards against overload conditions and phase failure across a current setting range of 0.31 - 0.41 A. This electromechanical device carries trip class 10 and connects directly to mini contactors or block contactors.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: T16-0.41\u003c\/li\u003e\n\u003cli\u003eABB article number: 1SAZ711201R1014\u003c\/li\u003e\n\u003cli\u003eEAN: 4013614404672\u003c\/li\u003e\n\u003cli\u003eType: Thermal overload relay\u003c\/li\u003e\n\u003cli\u003eCurrent setting range: 0.31 - 0.41 A\u003c\/li\u003e\n\u003cli\u003eTrip class: 10\u003c\/li\u003e\n\u003cli\u003eTrip contact: NC\u003c\/li\u003e\n\u003cli\u003eSignal contact: NO\u003c\/li\u003e\n\u003cli\u003eReset mode: Automatic or manual (selectable)\u003c\/li\u003e\n\u003cli\u003eMounting: Direct connection to mini contactors or block contactors\u003c\/li\u003e\n\u003cli\u003eAccessory: Single mounting kits available separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrip class 10 rating delivers fast disconnection when motor overload or phase failure is detected\u003c\/li\u003e\n\u003cli\u003eTemperature compensation keeps trip thresholds accurate across varying ambient conditions\u003c\/li\u003e\n\u003cli\u003eTrip-free mechanism with STOP function prevents the relay from being held closed during a fault\u003c\/li\u003e\n\u003cli\u003eSelectable automatic or manual reset provides flexibility in circuit recovery after a trip event\u003c\/li\u003e\n\u003cli\u003eDedicated trip indication makes fault identification straightforward on site\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMotor protection in industrial control panels at low current levels (0.31 - 0.41 A)\u003c\/li\u003e\n\u003cli\u003eStarter assemblies built around mini contactors or block contactors\u003c\/li\u003e\n\u003cli\u003eAutomation equipment and machinery requiring overload and phase failure protection\u003c\/li\u003e\n\u003cli\u003eProcess control systems where compact, direct-mount motor protection is needed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: ABB T16-0.41, T16-0.41 1SAZ711201R1014, 1SAZ711201R1014, thermal overload relay 0.41 A, ABB motor overload relay.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56098815803656,"sku":"ABB1SAZ711201R1014","price":17.74,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/1saz711201r1014-abb-t16-041-thermal-overload-relay-031-041-a-8878217.jpg?v=1775523388"}],"url":"https:\/\/gabbyelectric.com\/collections\/thermal-overload-relays.oembed?page=3","provider":"Gabby Electric","version":"1.0","type":"link"}