{"title":"Schneider Electric Miniature Circuit Breakers","description":"\u003cp\u003eExplore Schneider Electric miniature circuit breakers engineered for dependable protection against overloads and short circuits. Ideal for homes, offices, and industrial systems. Premium quality with fast EU-wide delivery.\u003c\/p\u003e","products":[{"product_id":"18637-miniature-circuit-breaker-mcb-acti9-ng125n-3p-40a-c-curve-25ka-iec-en-60947-2","title":"Schneider 18637 Miniature circuit breaker (MCB)","description":"\u003cp\u003eSchneider Electric 18637 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 NG125N range, rated at 40 A with a C tripping curve and a breaking capacity of 25 kA at 380-415 V AC per IEC 60947-2. Designed for electrical power distribution, it supports both AC and DC networks with thermomagnetic protection technology.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 18637\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 NG125\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: NG125N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A at 40°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 50 kA at 220-240 V AC; 25 kA at 380-415 V AC; 20 kA at 440 V AC; 10 kA at 500 V AC; 20 kA at up to 375 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 37.5 kA (220-240 V AC); 18.75 kA (380-415 V AC); 15 kA (440 V AC); 7.5 kA (500 V AC)\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 220-240 V \/ 380-415 V \/ 440 V \/ 500 V AC 50\/60 Hz; up to 375 V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 8 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eIK protection: IK05 (EN\/IEC 62262)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -30 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 70°C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm symmetrical DIN rail, click-on\u003c\/li\u003e\n  \u003cli\u003eHandle position: Vertical\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel terminals 1.5-50 mm² (rigid); 1-35 mm² (flexible)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStrip length: 20 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 81 x 103 x 81 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.72 kg\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eBusbar comb rail compatible: Yes (9 mm pitch)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh breaking capacity of 25 kA at 380-415 V AC suitable for demanding industrial and commercial installations\u003c\/li\u003e\n  \u003cli\u003eDual AC\/DC network compatibility provides flexibility across a wide range of electrical systems\u003c\/li\u003e\n  \u003cli\u003eIntegrated locking preparation allows the handle to be padlocked in the OFF position for safe isolation\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator enable quick visual status checks\u003c\/li\u003e\n  \u003cli\u003eClick-on DIN rail mounting and comb busbar compatibility simplify panel assembly\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-30 to 70°C) suits both indoor and harsh-environment enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal and sub-distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in main distribution panels\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery storage installations\u003c\/li\u003e\n  \u003cli\u003eMotor and equipment protection in industrial automation panels\u003c\/li\u003e\n  \u003cli\u003eHigh-fault-level environments requiring elevated breaking capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 NG125 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 18637, Schneider Electric 18637, Schneider NG125N 40A 3P MCB, Acti9 NG125N 40A circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065313718536,"sku":"SCH18637","price":92.21,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/18637-miniature-circuit-breaker-mcb-acti9-ng125n-3p-40a-c-curve-25ka-iecen-60947-2-162200.jpg?v=1735224427"},{"product_id":"a9a26476-shunt-trip-release-acti9-imx-voltage-release-100-415-v-ac","title":"Schneider A9A26476 Acti9 iMX Shunt Trip Release 100-415V AC","description":"\u003cp\u003eThe Schneider Electric A9A26476 is a shunt trip release (iMX) from the Acti 9 range, designed to remotely trip compatible circuit breakers upon application of a control voltage. It accepts a wide control voltage range of 100-415 V AC (50\/60 Hz) or 110-130 V DC, making it suitable for diverse electrical installations. The unit occupies just 2 rows on a 9 mm pitch DIN rail and has an 18 mm width for compact panel integration.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9A26476\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9\u003c\/li\u003e\n  \u003cli\u003eProduct type: Shunt trip release\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iMX\u003c\/li\u003e\n  \u003cli\u003eControl circuit voltage: 100-415 V AC 50\/60 Hz \/ 110-130 V DC\u003c\/li\u003e\n  \u003cli\u003e9 mm pitch rows: 2\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n  \u003cli\u003eMounting: Click-on system on DIN rail\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block: Top and bottom compatible\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminal - 2 x 2.5 mm² flexible, 2 x 2.5 mm² rigid, 1 x 4 mm² flexible, 1 x 6 mm² rigid\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1 N.m\u003c\/li\u003e\n  \u003cli\u003eLocal signaling: Action indicator\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85°C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eTropicalization: Class 2 per EN\/IEC 60947-5-1\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60947-1\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eWide control voltage range (100-415 V AC \/ 110-130 V DC) allows use across different supply systems without requiring separate accessories\u003c\/li\u003e\n  \u003cli\u003eClick-on DIN rail mounting ensures fast, tool-free installation in distribution boards\u003c\/li\u003e\n  \u003cli\u003eAction indicator provides local visual confirmation of trip operation\u003c\/li\u003e\n  \u003cli\u003eCompatible with a broad range of Acti 9 devices including iC65, iC60, iC40, iID, iDPN Vigi, iSW-NA, and ARA\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm width minimises panel space consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRemote tripping of Acti 9 circuit breakers in residential and commercial distribution boards\u003c\/li\u003e\n  \u003cli\u003eFire alarm or emergency shutdown systems requiring voltage-triggered breaker release\u003c\/li\u003e\n  \u003cli\u003eBuilding management systems where remote disconnection of circuits is needed\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels using Acti 9 iC60 or iC65 breakers with remote trip functionality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-1 and tropicalization class 2 per EN\/IEC 60947-5-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9A26476, Schneider Electric A9A26476, Acti9 iMX shunt release, Acti 9 voltage trip unit.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065320665352,"sku":"SCHA9A26476","price":32.42,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9a26476-shunt-trip-release-acti9-imx-voltage-release-100415-v-ac-926357.jpg?v=1735229659"},{"product_id":"a9a26927-auxiliary-contact-acti9-isd-1oc-ac-dc","title":"Schneider A9A26927 Acti9 Auxiliary Contact iSD 1 OC AC\/DC","description":"\u003cp\u003eThe Schneider Electric A9A26927 is an Acti9 iSD auxiliary contact block with one open contact (OC) for Acti9 MCBs. The iSD (state detector) contact follows the switching state of the MCB, closing when the MCB is ON and opening when it is OFF or tripped, for remote status indication. Compatible with AC and DC monitoring circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePart number: A9A26927\u003c\/li\u003e\n\u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli\u003eSeries: Acti9 accessories\u003c\/li\u003e\n\u003cli\u003eType: Auxiliary contact block iSD, side mounting\u003c\/li\u003e\n\u003cli\u003eContacts: 1 OC (open contact)\u003c\/li\u003e\n\u003cli\u003eCompatible with: Acti9 MCBs\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSingle-contact MCB state monitoring for distribution board management systems\u003c\/li\u003e\n\u003cli\u003eSimple ON\/OFF state signalling from Acti9 MCBs to remote indicators\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Schneider A9A26927, Acti9 iSD auxiliary contact 1OC, A9A26927 MCB state contact block.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065321124104,"sku":"SCHA9A26927","price":7.77,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9a26927-auxiliary-contact-acti9-isd-1oc-acdc-228612.jpg?v=1735229659"},{"product_id":"a9n18364-miniature-circuit-breaker-mcb-acti9-c120n-3p-63a-c-curve-10000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9N18364 Acti9 C120N MCB 3P 63 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18364 is the Acti 9 C120N 3-pole miniature circuit breaker (MCB) rated at 63 A with a C tripping curve, designed for electrical power distribution. It delivers a breaking capacity of 10 kA Icn at 230...400 V AC per EN\/IEC 60898-1, with a thermomagnetic protection unit providing reliable overcurrent and short-circuit protection.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9N18364\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 C120\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 63 A at 30°C\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 230...400 V AC \/ up to 440 V AC \/ up to 375 V DC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 10 kA at 230...400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUltimate breaking capacity [Icu]: 20 kA at 220...240 V AC, 10 kA at 380...415 V AC, 6 kA at 440 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, 35 mm symmetric DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals, 1...50 mm² rigid \/ 1.5...35 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 81 x 81 x 73 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.615 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCertification: EAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per IEC 60947-2, enabling safe maintenance disconnection\u003c\/li\u003e\n  \u003cli\u003eHandle sealable in ON or OFF position for tamper-evident installations\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbars for efficient wiring in distribution boards\u003c\/li\u003e\n  \u003cli\u003eCovers both AC and DC networks, rated up to 440 V AC and 375 V DC\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category IV, suitable for use at the origin of the electrical installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThree-phase distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection for three-phase sub-circuits at 63 A\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring high breaking capacity at 10 kA\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring isolation capability with sealed handle security\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 C120 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9N18364, Schneider Electric A9N18364, C120N 3P 63A MCB, Acti9 C120N circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065331380488,"sku":"SCHA9N18364","price":62.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18364-miniature-circuit-breaker-mcb-acti9-c120n-3p-63a-c-curve-10000a-iecen-60898-1-10ka-iecen-60947-2-706526.jpg?v=1735231069"},{"product_id":"a9n18365-miniature-circuit-breaker-mcb-acti9-c120n-3p-80a-c-curve-10000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9N18365 Acti9 C120N MCB 3P 80 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18365 is a 3-pole 80 A miniature circuit breaker (MCB) from the Acti 9 C120N series, designed for electrical power distribution. It features a type C tripping curve and thermomagnetic protection, with a breaking capacity of 10 kA Icn at 230...400 V AC per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9N18365\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 C120\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P (3 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current: 80 A at 30°C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eRated voltage: 230...400 V AC, 440 V AC, 220...240 V AC, up to 375 V DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 10 kA at 230...400 V AC (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220...240 V AC, 10 kA at 380...415 V AC, 6 kA at 440 V AC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm symmetrical DIN rail, snap-on\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals 1...50 mm² rigid \/ 1.5...35 mm² flexible; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 81 x 81 x 73 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.615 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCertification: EAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection delivers reliable overcurrent and short-circuit defence\u003c\/li\u003e\n  \u003cli\u003eHandle sealable with 0.7 mm cable in ON or OFF position for tamper resistance\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks for fast DIN rail panel assembly\u003c\/li\u003e\n  \u003cli\u003eWide cable acceptance (1...50 mm² rigid, 1.5...35 mm² flexible) suits varied wiring\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolator per IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain and sub-distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in low-voltage distribution panels\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels with high short-circuit current requirements\u003c\/li\u003e\n  \u003cli\u003eMixed AC and DC network installations requiring overvoltage category IV protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 C120 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9N18365, Schneider Electric A9N18365, C120N 3P 80A MCB, Acti9 C120N circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065331413256,"sku":"SCHA9N18365","price":96.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18365-miniature-circuit-breaker-mcb-acti9-c120n-3p-80a-c-curve-10000a-iecen-60898-1-10ka-iecen-60947-2-886409.jpg?v=1735231075"},{"product_id":"a9n18367-miniature-circuit-breaker-mcb-acti9-c120n-3p-100a-c-curve-10000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9N18367 Acti9 C120N MCB 3P 100 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18367 is a 3-pole 100 A miniature circuit breaker (MCB) from the Acti 9 C120N range, featuring a C tripping curve and thermomagnetic protection technology. Designed for electrical energy distribution, it delivers a breaking capacity of 10,000 A Icn at 230-400 V AC per EN\/IEC 60898-1, suitable for commercial and industrial panel installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9N18367\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 C120\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 100 A at 30°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 10,000 A at 230-400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220-240 V AC \/ 10 kA at 380-415 V AC \/ 6 kA at 440 V AC \/ 10 kA at \u0026lt;=375 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm symmetrical DIN rail, click-fit\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 81 x 81 x 73 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.615 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 70°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals 1-50 mm² solid \/ 1.5-35 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eCertification: EAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per IEC 60947-2, enabling safe disconnection of circuits\u003c\/li\u003e\n  \u003cli\u003eHandle sealable in OFF or ON position with 0.7 mm cable to prevent unauthorized switching\u003c\/li\u003e\n  \u003cli\u003eCompatible with busbar comb distribution blocks for flexible panel wiring\u003c\/li\u003e\n  \u003cli\u003eContact position indicator with ON\/OFF local readout for clear circuit status monitoring\u003c\/li\u003e\n  \u003cli\u003eOperable up to 2000 m altitude and 95% relative humidity at 55°C\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance 20,000 cycles; electrical endurance 5,000 cycles per IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain and sub-distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in low-voltage switchboards\u003c\/li\u003e\n  \u003cli\u003eThree-phase distribution panels requiring 100 A overcurrent and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring safe isolation capability within panel assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2 and EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 C120 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9N18367, Schneider Electric A9N18367, C120N 3P 100A MCB, Acti9 C120N circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065331478792,"sku":"SCHA9N18367","price":99.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18367-miniature-circuit-breaker-mcb-acti9-c120n-3p-100a-c-curve-10000a-iecen-60898-1-10ka-iecen-60947-2-466654.jpg?v=1735231075"},{"product_id":"a9n18369-miniature-circuit-breaker-mcb-acti9-c120n-3p-125a-c-curve-10000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9N18369 Acti9 C120N MCB 1P 6 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18369 is a 3-pole 125 A Miniature Circuit Breaker (MCB) from the Acti 9 C120N range, designed for electrical power distribution. Featuring a C tripping curve and thermomagnetic protection unit, it delivers a rated breaking capacity of 10 kA Icn at 230...400 V AC per EN\/IEC 60898-1 and up to 20 kA Icu at 220...240 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9N18369\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 C120\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current: 125 A at 30°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eRated voltage: 220...440 V AC 50\/60 Hz; up to 375 V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 10 kA at 230...400 V AC - EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220...240 V AC; 10 kA at 380...415 V AC; 6 kA at 440 V AC - EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm symmetrical DIN rail, clip-on\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals, 1...50 mm² solid \/ 1.5...35 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 81 x 81 x 73 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.615 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-2, EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertification: EAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC tripping curve with 5...10 x In range, suitable for loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting for fast, tool-free installation in distribution boards\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks for efficient multi-pole busbar connection\u003c\/li\u003e\n  \u003cli\u003eLockable handle in ON or OFF position for tamper-proof lockout\/tagout\u003c\/li\u003e\n  \u003cli\u003eON\/OFF contact position indicator for clear local status reading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards and sub-distribution panels in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of cables and equipment in industrial automation and control panels\u003c\/li\u003e\n  \u003cli\u003ePower distribution switchgear assemblies requiring IEC 60947-2 compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2 and EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9N18369, Schneider Electric A9N18369, C120N 3P 125A MCB, Acti9 C120N 125A circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065332494600,"sku":"SCHA9N18369","price":155.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18369-miniature-circuit-breaker-mcb-acti9-c120n-3p-125a-c-curve-10000a-iecen-60898-1-10ka-iecen-60947-2-676520.jpg?v=1735231075"},{"product_id":"a9n26476-mx-shunt-trip-415vac-110-130vdc","title":"Schneider A9N26476 Acti9 MX Shunt Trip 415V AC 110-130V DC","description":"\u003cp\u003eThe Schneider Electric A9N26476 is a shunt trip release (MX voltage release) for the Acti 9 range, designed to remotely trip compatible circuit breakers when control circuit voltage is applied. The control circuit voltage range covers 100-415 V AC 50\/60 Hz and 110-130 V DC, making it suitable for a wide variety of control supply sources. It occupies 2 DIN rail rows at 9 mm pitch width per row.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9N26476\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9\u003c\/li\u003e\n  \u003cli\u003eProduct type: Shunt trip release (MX voltage release)\u003c\/li\u003e\n  \u003cli\u003eControl circuit voltage: 100-415 V AC 50\/60 Hz \/ 110-130 V DC\u003c\/li\u003e\n  \u003cli\u003e9 mm rows: 2\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, 35 mm symmetrical DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 82.5 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 73.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 60 g\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminal block (bottom) - 2 cables 1.5 mm² flexible \/ flexible with ferrule \/ 1 cable 0.5-2.5 mm² rigid\u003c\/li\u003e\n  \u003cli\u003eStrip length: 9 mm (bottom connection)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 1 N.m (bottom)\u003c\/li\u003e\n  \u003cli\u003eLocal indication: Action indicator\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 50 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eTropicalization: Class 2 per EN\/IEC 60947-5-1\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: KEMA, ASEFA, LCIE, ASTA\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eWide control voltage range (100-415 V AC and 110-130 V DC) allows integration with diverse control systems without additional transformers\u003c\/li\u003e\n  \u003cli\u003eCompatible with a broad range of Acti 9 devices including iDPN, C120, C60H-DC, DPN Vigi, IDc, and others\u003c\/li\u003e\n  \u003cli\u003eBuilt-in action indicator provides local visual confirmation of trip operation\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm width minimises panel space consumption\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block compatible (top), simplifying panel wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRemote tripping of Acti 9 circuit breakers in residential and commercial distribution boards\u003c\/li\u003e\n  \u003cli\u003eEmergency power-off (EPO) circuits requiring remote disconnection via voltage signal\u003c\/li\u003e\n  \u003cli\u003eFire alarm or safety interlock systems triggering automatic circuit disconnection\u003c\/li\u003e\n  \u003cli\u003eBuilding management systems requiring automated breaker control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9N26476, Schneider Electric A9N26476, Acti9 MX shunt trip release, Acti 9 voltage release accessory.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065332592904,"sku":"SCHA9N26476","price":30.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n26476-mx-shunt-trip-415vac-110-130vdc-118126.jpg?v=1735231202"},{"product_id":"a9f73106-miniature-circuit-breaker-mcb-acti9-ic60n-1p-6a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73106 Acti9 iC60N MCB 1P 6 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73106 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 6 A with a B tripping curve. Designed for AC and DC networks, it delivers a rated breaking capacity (Icn) of 6000 A at 230 V AC and an ultimate breaking capacity (Icu) of 10 kA at 220-240 V AC, providing reliable overcurrent protection in power distribution applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73106\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB), iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 6 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 230 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eUltimate breaking capacity (Icu): 10 kA at 220-240 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1-25 mm² rigid \/ 1-16 mm² flexible; strip length 14 mm; tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85 °C\u003c\/li\u003e\n  \u003cli\u003eStandards: EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eTrip indicator for immediate local fault signalling\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower connection\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70 °C for demanding environments\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category IV and pollution degree 3, rated for origin-of-installation use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and socket outlet circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring compact 18 mm wide single-pole protection\u003c\/li\u003e\n  \u003cli\u003eLow-voltage DC distribution systems up to 72 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73106, Schneider Electric A9F73106, iC60N 6A B curve MCB, Acti9 1P miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065504821512,"sku":"SCHA9F73106","price":4.46,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73106-miniature-circuit-breaker-mcb-acti9-ic60n-1p-6a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-140940.jpg?v=1735230349"},{"product_id":"a9f73110-miniature-circuit-breaker-mcb-acti9-ic60n-1p-10a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73110 Acti9 iC60N MCB 1P 10 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73110 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 10 A with a B tripping curve. Designed for electrical energy distribution, it provides thermomagnetic protection on both AC and DC networks, with a breaking capacity of 6,000 A Icn at 230 V AC per EN\/IEC 60898-1 and 10 kA Icu at 220-240 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73110\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current: 10 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 230 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 220-240 V AC 50\/60 Hz \/ 10 kA at 72 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB tripping curve suited to resistive and lighting loads with low inrush currents\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks for flexible application\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block compatible on upper or lower connection\u003c\/li\u003e\n  \u003cli\u003eTrip indicator provides quick local fault signaling\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eHigh mechanical endurance of 20,000 cycles and electrical endurance of 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and resistive load circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and electrical enclosures\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems including low-voltage DC installations\u003c\/li\u003e\n  \u003cli\u003eElectrical installations requiring isolation capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73110, Schneider Electric A9F73110, iC60N 10A B curve MCB, Acti9 1P 10A miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065504919816,"sku":"SCHA9F73110","price":3.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73110-miniature-circuit-breaker-mcb-acti9-ic60n-1p-10a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-457921.jpg?v=1735230353"},{"product_id":"a9f73116-miniature-circuit-breaker-mcb-acti9-ic60n-1p-16a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73116 Acti9 iC60N MCB 1P 16 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73116 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 16 A with a B tripping curve and thermomagnetic protection technology. It delivers overcurrent and short-circuit protection on both AC and DC networks, with a breaking capacity of 6000 A Icn at 230 V AC per EN\/IEC 60898-1 and 10 kA Icu at 220-240 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73116\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current: 16 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 230 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 220-240 V AC 50\/60 Hz; 36 kA at 12-60 V AC; 10 kA at 72 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm | Height: 85 mm | Depth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-25 mm² rigid \/ 1-16 mm² flexible conductors (upper or lower)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB tripping curve provides sensitive overcurrent protection suited to circuits with low inrush currents\u003c\/li\u003e\n  \u003cli\u003eRated for both AC and DC networks, enabling use in photovoltaic and battery-backed systems\u003c\/li\u003e\n  \u003cli\u003eCertified as a disconnecting device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBuilt-in trip indicator allows quick local fault identification without additional instrumentation\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm (2 x 9 mm module) width maximises usable panel space\u003c\/li\u003e\n  \u003cli\u003eTropicalization class 2 per IEC 60068-1 for reliable operation in high-humidity environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and light commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and socket outlet circuits with low inrush loads\u003c\/li\u003e\n  \u003cli\u003eDC distribution in photovoltaic installations and battery storage systems\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and switchgear assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73116, Schneider Electric A9F73116, iC60N 16A B curve MCB, Acti 9 miniature circuit breaker 16A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065504952584,"sku":"SCHA9F73116","price":3.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73116-miniature-circuit-breaker-mcb-acti9-ic60n-1p-16a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-548116.jpg?v=1735230350"},{"product_id":"a9f73120-miniature-circuit-breaker-mcb-acti9-ic60n-1p-20a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73120 Acti9 iC60N MCB 1P 20 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73120 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 20 A with a B tripping curve. Designed for electrical distribution, it offers a breaking capacity of 6000 A at 230 V AC and 10 kA at 240 V AC, with compatibility for both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73120\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current: 20 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 230 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 240 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 72 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 15 kA at 12-60 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for both AC and DC network applications, providing versatile deployment options\u003c\/li\u003e\n  \u003cli\u003eB tripping curve provides sensitive overcurrent protection suited to resistive and light inductive loads\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimizes let-through energy, enhancing downstream equipment protection\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator enable quick local status verification\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible (top or bottom) for streamlined distribution board assembly\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm width maximizes panel space efficiency on DIN rail installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial electrical installations\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and resistive loads requiring sensitive B curve tripping\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery-backed systems up to 72 V DC\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and low-voltage electrical distribution enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73120, Schneider Electric A9F73120, Acti9 iC60N 20A MCB, Schneider 1P 20A B curve circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065505018120,"sku":"SCHA9F73120","price":3.11,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73120-miniature-circuit-breaker-mcb-acti9-ic60n-1p-20a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-270674.jpg?v=1735230356"},{"product_id":"a9f73125-miniature-circuit-breaker-mcb-acti9-ic60n-1p-25a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73125 Acti9 iC60N MCB 1P 25 A B Curve 10kA","description":"\u003cp\u003eSchneider Electric A9F73125 is a 1-pole, 25 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, designed for electrical power distribution. It features a B tripping curve with a breaking capacity of 10 kA at 220-240 V AC and is suitable for both AC and DC network types.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73125\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 25 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 230 V AC 50\/60 Hz per EN\/IEC 60898-1; 10 kA Icu at 220-240 V AC per EN\/IEC 60947-2; 15 kA Icu at 12-60 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 7.5 kA (75%) at 220-240 V AC; 6000 A (100%) at 230 V AC per EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eUtilization category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStripping length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for both AC and DC networks, offering flexibility across different installation types\u003c\/li\u003e\n  \u003cli\u003eB tripping curve provides sensitive overcurrent protection, ideal for loads with low inrush currents\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces energy let-through during fault conditions\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator provide clear local status signalling\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks (top or bottom), simplifying panel wiring\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation duty per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and low-inrush electrical loads\u003c\/li\u003e\n  \u003cli\u003eDC power distribution systems at voltages up to 72 V\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring compact 18 mm DIN rail mounted protection\u003c\/li\u003e\n  \u003cli\u003eElectrical power distribution switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73125, Schneider Electric A9F73125, iC60N 1P 25A B curve MCB, Acti9 miniature circuit breaker 25A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065505083656,"sku":"SCHA9F73125","price":3.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73125-miniature-circuit-breaker-mcb-acti9-ic60n-1p-25a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-530789.jpg?v=1735230350"},{"product_id":"a9f73132-miniature-circuit-breaker-mcb-acti9-ic60n-1p-32a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73132 Acti9 iC60N MCB 1P 32 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73132 is a 1-pole, 32 A Miniature Circuit Breaker from the Acti 9 iC60N series, designed for electrical energy distribution. It combines a B tripping curve with thermomagnetic protection, delivering 6,000 A Icn at 230 V AC per IEC 60898-1 and 10 kA Icu at 220-240 V AC per IEC 60947-2. Rated for both AC and DC networks, it provides reliable overcurrent and short-circuit protection.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73132\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current: 32 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70 °C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1...35 mm² rigid \/ 1...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60898-1, IEC 60947-2, EN 60898-1, EN 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection with B tripping curve for reliable overcurrent and short-circuit disconnection\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection threshold at 4 x In +\/-20% per the product specifications\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks, offering broad installation flexibility\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting with comb busbar distribution block compatibility, upper or lower connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and light commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of circuits in low-voltage electrical installations\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in low-voltage DC distribution systems\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and low-voltage distribution switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, IEC 60947-2, EN 60898-1, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73132, Schneider Electric A9F73132, iC60N 1P 32A B curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065505509640,"sku":"SCHA9F73132","price":4.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73132-miniature-circuit-breaker-mcb-acti9-ic60n-1p-32a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-823003.jpg?v=1735230349"},{"product_id":"a9f73140-miniature-circuit-breaker-mcb-acti9-ic60n-1p-40a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73140 Acti9 iC60N MCB 1P 40 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73140 is a single-pole miniature circuit breaker from the Acti9 iC60N range, rated 40 A with B tripping curve. It provides overload and short-circuit protection for final circuits in distribution boards, rated 6000A under IEC\/EN 60898-1 and 10kA under IEC\/EN 60947-2. Mounts on 35mm DIN rail in 18mm module widths per pole.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePart number: A9F73140\u003c\/li\u003e\n\u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli\u003eSeries: Acti9 iC60N\u003c\/li\u003e\n\u003cli\u003ePoles: 1P\u003c\/li\u003e\n\u003cli\u003eRated current: 40 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: B\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (IEC 60898-1): 6000A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (IEC 60947-2): 10kA\u003c\/li\u003e\n\u003cli\u003eRated voltage: 230V AC (line to neutral)\u003c\/li\u003e\n\u003cli\u003eMounting: 35mm DIN rail, 18mm\/pole\u003c\/li\u003e\n\u003cli\u003eStandards: IEC\/EN 60898-1, IEC\/EN 60947-2, CE\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eB curve - suited to general wiring protection where low-inrush loads such as resistive heating, lighting, and cable protection are involved\u003c\/li\u003e\n\u003cli\u003eActi9 system - compatible with Vigi RCD blocks, auxiliary contacts, shunt trips, and Acti9 comb busbars\u003c\/li\u003e\n\u003cli\u003e18mm\/pole width - standard Acti9 pitch, slots into any Multi 9 distribution board row\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection in domestic, commercial, and industrial distribution boards\u003c\/li\u003e\n\u003cli\u003eSub-distribution panels and MCB boards using 18mm DIN rail modules\u003c\/li\u003e\n\u003cli\u003eActi9 assemblies with Vigi RCD blocks for combined MCB+RCD protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Schneider A9F73140, Acti9 iC60N 1P 40 A B curve MCB, A9F73140 miniature circuit breaker 40 A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065505575176,"sku":"SCHA9F73140","price":5.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73140-miniature-circuit-breaker-mcb-acti9-ic60n-1p-40a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-100297.jpg?v=1735230357"},{"product_id":"a9f73163-miniature-circuit-breaker-mcb-acti9-ic60n-1p-63a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73163 Acti9 iC60N MCB 1P 63 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73163 is a 1-pole Miniature Circuit Breaker (MCB) from the Acti 9 iC60N range, rated at 63 A with a B tripping curve. Suitable for both AC and DC networks, it delivers a breaking capacity of 6,000 A (Icn) at 230 V AC and 10 kA (Icu) at 220-240 V AC, making it well suited for electrical energy distribution applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73163\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current: 63 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 230 V AC 50\/60 Hz per IEC\/EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 220-240 V AC 50\/60 Hz per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7.5 kA at 220-240 V AC 50\/60 Hz per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: single terminal block, 1-35 mm² rigid \/ 1-25 mm² flexible, tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for use as an isolating device per IEC\/EN 60898-1 and IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eBuilt-in trip indicator for rapid fault identification without opening the enclosure\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003eRated for overvoltage category IV and pollution degree 3, suitable for demanding environments\u003c\/li\u003e\n  \u003cli\u003eTropicalized per IEC 60068-1, with 95% relative humidity tolerance at 55°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection in electrical energy distribution panels\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery system installations\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring overvoltage category IV protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 60898-1 and IEC\/EN 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73163, Schneider Electric A9F73163, iC60N 63A B curve MCB, Acti9 1-pole 63A miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065505673480,"sku":"SCHA9F73163","price":8.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73163-miniature-circuit-breaker-mcb-acti9-ic60n-1p-63a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-614030.jpg?v=1735230357"},{"product_id":"a9f73302-miniature-circuit-breaker-mcb-acti9-ic60n-3p-2a-b-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F73302 Acti9 iC60N MCB 3P 2 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73302 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 2 A with a B tripping curve for electrical energy distribution on AC and DC networks. Thermomagnetic protection technology guards against both overload and short-circuit conditions. Breaking capacity is 6000 A Icn at 400 V AC per IEC 60898-1, rising to 50 kA Icu at 380-415 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73302\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P, 3 protected poles\u003c\/li\u003e\n  \u003cli\u003eRated current: 2 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 50 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 50 kA at 380-415 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 25 kA at 440 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at up to 180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 50 kA 100% at 380-415 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3 per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eTropicalization: Class 2 per IEC 60068-1\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (upper or lower), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm; tightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block: Compatible, upper or lower\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60898-1, EN 60898-1, IEC 60947-2, EN 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB tripping curve provides overcurrent protection suited to circuits with low starting currents\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN 60898-1 and EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals for flexible panel wiring\u003c\/li\u003e\n  \u003cli\u003eTrip indicator enables local fault signaling without additional instrumentation\u003c\/li\u003e\n  \u003cli\u003eTropicalized construction (Class 2 per IEC 60068-1) for reliable operation in demanding environments\u003c\/li\u003e\n  \u003cli\u003eHigh mechanical durability rated at 20,000 operating cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards for electrical energy distribution in residential and commercial installations\u003c\/li\u003e\n  \u003cli\u003eIndustrial switchgear panels requiring 3-pole B-curve overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection up to 180 V in low-voltage DC distribution systems\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounted assemblies with comb busbar connectivity\u003c\/li\u003e\n  \u003cli\u003eControl panels requiring an isolating-rated MCB per IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73302, Schneider Electric A9F73302, iC60N 3P 2A B curve MCB, Acti9 miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065506590984,"sku":"SCHA9F73302","price":18.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73302-miniature-circuit-breaker-mcb-acti9-ic60n-3p-2a-b-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-766411.jpg?v=1735230354"},{"product_id":"a9f73304-miniature-circuit-breaker-mcb-acti9-ic60n-3p-4a-b-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F73304 Acti9 iC60N MCB 3P 4 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73304 is a 3-pole 4 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, featuring a B tripping curve and thermomagnetic protection technology. Compatible with both AC and DC networks, it delivers a breaking capacity of 6,000 A Icn at 400 V AC per IEC 60898-1 and up to 50 kA Icu at 380-415 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73304\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P (3 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current: 4 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 400 V AC per IEC\/EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 50 kA at 380-415 V AC, 25 kA at 440 V AC, 10 kA at up to 180 V DC per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per IEC\/EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eUtilization category: Category A per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1-25 mm² rigid \/ 1-16 mm² flexible, tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60898-1, EN 60898-1, IEC 60947-2, EN 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic trip unit provides reliable protection against overloads and short circuits\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks, upper or lower connection, 9 mm pitch\u003c\/li\u003e\n  \u003cli\u003eLocal trip indicator enables fast visual fault identification\u003c\/li\u003e\n  \u003cli\u003eHigh durability with 20,000 mechanical cycles and 10,000 electrical cycles\u003c\/li\u003e\n  \u003cli\u003eSuitable for both AC and DC networks for versatile panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eDC power distribution systems up to 180 V\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring overvoltage category IV and pollution degree 3 compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73304, Schneider Electric A9F73304, Acti9 iC60N 4A B curve MCB, 3-pole miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065507377416,"sku":"SCHA9F73304","price":16.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73304-miniature-circuit-breaker-mcb-acti9-ic60n-3p-4a-b-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-411341.jpg?v=1735230354"},{"product_id":"a9f73306-miniature-circuit-breaker-mcb-acti9-ic60n-3p-6a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73306 Acti9 iC60N MCB 3P 6 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73306 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 6 A with a B tripping curve. Designed for electrical power distribution, it provides thermomagnetic overcurrent protection with a breaking capacity of 10 kA at 380-415 V AC, making it suitable for both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73306\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort designation: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current: 6 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220-240 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at up to 180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 54 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-2, IEC 60898-1, EN 60947-2, EN 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection technology ensures reliable overcurrent and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eB tripping curve optimised for circuits with low inrush current loads such as resistive and lighting applications\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks (top or bottom), simplifying panel wiring\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator enable quick visual status verification\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-35 to 70 °C) and tropicalisation class 2 for demanding environments\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation duty per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and resistive loads in electrical panels\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring AC or DC circuit protection\u003c\/li\u003e\n  \u003cli\u003eLow-voltage power distribution switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-2, IEC 60898-1, EN 60947-2, and EN 60898-1. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73306, Schneider Electric A9F73306, iC60N 3P 6A B curve MCB, Acti9 miniature circuit breaker 6A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065507508488,"sku":"SCHA9F73306","price":13.01,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73306-miniature-circuit-breaker-mcb-acti9-ic60n-3p-6a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-470074.jpg?v=1735230354"},{"product_id":"a9f73310-ic60n-miniature-circuit-breaker-3p-10a-b-curve","title":"Schneider A9F73310 Acti9 iC60N MCB 3P 10 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73310 is a 3-pole, 10 A Miniature Circuit Breaker (MCB) from the Acti 9 iC60N series, designed for electrical power distribution. Featuring a B tripping curve and thermomagnetic protection technology, it delivers a breaking capacity of 10 kA at 380-415 V AC and supports both AC and DC network applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73310\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current: 10 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC; 20 kA at 220-240 V AC; 10 kA at up to 180 V DC (per EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7.5 kA at 380-415 V AC; 15 kA at 220-240 V AC (per EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm; Tightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection unit for reliable response to both overload and short-circuit conditions\u003c\/li\u003e\n  \u003cli\u003eB tripping curve suitable for sensitive loads requiring earlier magnetic trip activation\u003c\/li\u003e\n  \u003cli\u003eCompatible with upper or lower comb busbar distribution blocks for flexible panel wiring\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator for rapid local fault identification\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and sensitive low-power loads\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring DC circuit protection\u003c\/li\u003e\n  \u003cli\u003eElectrical distribution systems where B-curve tripping characteristics are specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73310, Schneider Electric A9F73310, iC60N 3P 10A B curve MCB, Acti9 miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065508163848,"sku":"SCHA9F73310","price":11.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73310-ic60n-miniature-circuit-breaker-3p-10a-b-curve-392107.jpg?v=1735230349"},{"product_id":"a9f73316-miniature-circuit-breaker-mcb-acti9-ic60n-3p-16a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73316 Acti9 iC60N MCB 3P 16 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73316 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 16 A with a B tripping curve. Designed for electrical power distribution, it provides thermomagnetic protection for both AC and DC networks, with a breaking capacity of 10 kA at 380-415 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73316\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 16 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 380-415 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 125-180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 7.5 kA (75%) at 380-415 V AC per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 54 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eProduct weight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eStandards: EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2, enabling safe disconnection of circuits\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks from top or bottom, simplifying panel wiring\u003c\/li\u003e\n  \u003cli\u003eTrip position indicator and trip flag provide clear local signalling of fault events\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 ensures fast current limitation, reducing thermal and mechanical stress on downstream equipment\u003c\/li\u003e\n  \u003cli\u003eOperates across a wide temperature range (-35 to 70 °C), suitable for demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring thermomagnetic overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eDC and AC mixed-network installations requiring versatile circuit protection\u003c\/li\u003e\n  \u003cli\u003eMotor and equipment branch circuit protection in light industrial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73316, Schneider Electric A9F73316, iC60N 3P 16A B curve MCB, Acti9 miniature circuit breaker 16A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065508262152,"sku":"SCHA9F73316","price":11.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73316-miniature-circuit-breaker-mcb-acti9-ic60n-3p-16a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-299015.jpg?v=1735230350"},{"product_id":"a9f73320-miniature-circuit-breaker-mcb-acti9-ic60n-3p-20a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73320 Acti9 iC60N MCB 3P 20 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73320 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 20 A with a B tripping curve. It provides thermomagnetic overcurrent protection for both AC and DC networks, with a breaking capacity of 10 kA at 380-415 V AC (IEC 60947-2).\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73320\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 20 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC 50\/60 Hz (EN\/IEC 60898-1); 10 kA Icu at 380-415 V AC 50\/60 Hz (EN\/IEC 60947-2); 20 kA Icu at 220-240 V AC 50\/60 Hz (EN\/IEC 60947-2); 10 kA Icu at up to 180 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 54 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eConnection: single terminal block (top or bottom), 1-25 mm² solid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB curve tripping characteristic suited for circuits with low inrush currents, providing sensitive protection against overloads and short circuits\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks for flexible installation in diverse distribution systems\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for fast visual diagnostics\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block compatible (top or bottom), simplifying panel wiring\u003c\/li\u003e\n  \u003cli\u003eColor: white; designed for fixed installation on standard DIN rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and low-inrush electrical loads\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and DC distribution systems\u003c\/li\u003e\n  \u003cli\u003eSwitchboards requiring compact 3-pole overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73320, Schneider Electric A9F73320, Acti9 iC60N 3P 20A B curve MCB, Schneider 3-pole miniature circuit breaker 20A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065508327688,"sku":"SCHA9F73320","price":11.44,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73320-miniature-circuit-breaker-mcb-acti9-ic60n-3p-20a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-255846.jpg?v=1735230349"},{"product_id":"a9f73325-miniature-circuit-breaker-mcb-acti9-ic60n-3p-25a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73325 Acti9 iC60N MCB 3P 25 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73325 is a 3-pole, 25 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, designed for electrical power distribution on AC and DC networks. It uses thermomagnetic protection with a B tripping curve and provides a rated breaking capacity of 6,000 A Icn at 400 V AC per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73325\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P (3 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current: 25 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380...415 V AC \/ 20 kA at 220...240 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1...25 mm² rigid \/ 1...16 mm² flexible; strip length 14 mm; torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB curve thermomagnetic protection with overcurrent trip threshold at 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks for versatile distribution panel design\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting with support for upper or lower comb busbar distribution blocks\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator for immediate local fault signalization\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 per EN\/IEC 60898-1 limits energy let-through during fault conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring circuit protection on AC or DC networks\u003c\/li\u003e\n  \u003cli\u003ePower distribution systems where a B tripping characteristic is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73325, Schneider Electric A9F73325, iC60N 3P 25A B curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065509835016,"sku":"SCHA9F73325","price":13.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73325-miniature-circuit-breaker-mcb-acti9-ic60n-3p-25a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-723721.jpg?v=1735230349"},{"product_id":"a9f73332-miniature-circuit-breaker-mcb-acti9-ic60n-3p-32a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73332 Acti9 iC60N MCB 3P 32 A B Curve 10kA","description":"\u003cp\u003eThe A9F73332 is a Schneider Electric Acti 9 iC60N 3-pole 32 A miniature circuit breaker with a B tripping curve, designed for overcurrent and short-circuit protection in AC and DC electrical distribution systems. It delivers a breaking capacity of 10 kA at 380-415 V AC per IEC\/EN 60947-2, with a thermomagnetic protection unit ensuring precise trip response.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73332\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 32 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 380-415 V AC; 20 kA at 220-240 V AC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-35 mm² rigid \/ 1-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV, pollution degree: 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB tripping curve provides sensitive short-circuit protection suited to circuits with low inrush currents\u003c\/li\u003e\n  \u003cli\u003eUsage category A per IEC\/EN 60947-2, with full isolation rating per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator enables immediate local fault signaling\u003c\/li\u003e\n  \u003cli\u003eCompatible with upper or lower comb busbar connection for faster panel wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and light industrial installations\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting, heating, and other low-inrush circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and DC network protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73332, Schneider Electric A9F73332, iC60N 3-pole 32A MCB, Acti 9 miniature circuit breaker 32A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065509900552,"sku":"SCHA9F73332","price":14.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73332-miniature-circuit-breaker-mcb-acti9-ic60n-3p-32a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-930421.jpg?v=1735230357"},{"product_id":"a9f73340-miniature-circuit-breaker-mcb-acti9-ic60n-3p-40a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73340 Acti9 iC60N MCB 3P 40 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73340 is a 3-pole 40 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, designed for electrical energy distribution applications. With a B tripping curve and thermomagnetic protection technology, it delivers a breaking capacity of 10 kA at 380-415 V AC and is rated for both AC and DC network types.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73340\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current: 40 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC per EN\/IEC 60898-1; 10 kA Icu at 380-415 V AC per EN\/IEC 60947-2; 10 kA Icu at up to 180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-35 mm² rigid \/ 1-25 mm² flexible; strip length 14 mm; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2, enabling safe maintenance procedures\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals for flexible panel wiring\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator for immediate local fault identification\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70°C with tropicalization grade 2 for humid environments up to 95% relative humidity at 55°C\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category IV for installation at the origin of electrical installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and resistive load circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and general electrical distribution systems\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in low-voltage distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73340, Schneider Electric A9F73340, iC60N 3P 40A B curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065510686984,"sku":"SCHA9F73340","price":18.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73340-miniature-circuit-breaker-mcb-acti9-ic60n-3p-40a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-965560.jpg?v=1735230350"},{"product_id":"a9f73350-miniature-circuit-breaker-mcb-acti9-ic60n-3p-50a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73350 Acti9 iC60N MCB 3P 50 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73350 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 50 A with a B tripping curve for overload and short-circuit protection in electrical distribution systems. It supports both AC and DC networks and delivers a breaking capacity of 10 kA Icu at 380-415 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73350\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P, 3 protected poles\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 50 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC per EN\/IEC 60898-1; 10 kA Icu at 380-415 V AC; 20 kA Icu at 220-240 V AC; 10 kA Icu at up to 180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-35 mm² rigid \/ 1-25 mm² flexible; strip length 14 mm; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB tripping curve for early tripping, suited to sensitive loads and long cable runs\u003c\/li\u003e\n  \u003cli\u003eThermomagnetic protection unit for combined thermal and magnetic trip response\u003c\/li\u003e\n  \u003cli\u003eTrip indicator for fast local identification of a tripped state\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003e20,000 mechanical cycles and 10,000 electrical cycles endurance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eLow-voltage distribution panels requiring overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eIndustrial control cabinets and machinery protection circuits\u003c\/li\u003e\n  \u003cli\u003eDC network applications such as photovoltaic or battery-backed systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73350, Schneider Electric A9F73350, iC60N 3P 50A B curve MCB, Acti9 miniature circuit breaker 50A 3 pole.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065510785288,"sku":"SCHA9F73350","price":25.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73350-miniature-circuit-breaker-mcb-acti9-ic60n-3p-50a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-823939.jpg?v=1735230357"},{"product_id":"a9f73363-miniature-circuit-breaker-mcb-acti9-ic60n-3p-63a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73363 Acti9 iC60N MCB 3P 63 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73363 is a 3-pole, 63 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, providing thermomagnetic overcurrent and short-circuit protection in AC and DC distribution systems. Its B tripping curve and 10 kA breaking capacity at 380-415 V AC suit a wide range of low-voltage panel applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73363\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current: 63 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC (EN\/IEC 60898-1); 10 kA Icu at 380-415 V AC; 20 kA Icu at 220-240 V AC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-35 mm² rigid \/ 1-25 mm² flexible; strip length 14 mm; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMagnetic overcurrent trip threshold at 4 x In +\/- 20% for precise cable protection\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator enable fast fault diagnosis without panel opening\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on top or bottom terminals\u003c\/li\u003e\n  \u003cli\u003eHigh endurance rated at 20,000 mechanical cycles and 10,000 electrical cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eCable and conductor protection in low-voltage switchgear panels\u003c\/li\u003e\n  \u003cli\u003eDC distribution circuits requiring thermomagnetic circuit protection\u003c\/li\u003e\n  \u003cli\u003eLight industrial equipment and motor branch circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73363, Schneider Electric A9F73363, iC60N 3P 63A MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065510850824,"sku":"SCHA9F73363","price":31.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73363-miniature-circuit-breaker-mcb-acti9-ic60n-3p-63a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-429475.jpg?v=1735230351"},{"product_id":"a9f74102-miniature-circuit-breaker-mcb-acti9-ic60n-1p-2a-c-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F74102 Acti9 iC60N MCB 1P 2 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74102 is a 1-pole miniature circuit breaker from the Acti 9 iC60N range, rated at 2 A with a C tripping curve. It provides thermomagnetic protection for AC and DC networks, with a breaking capacity of 6000 A Icn at 230 V AC per EN\/IEC 60898-1 and up to 50 kA Icu per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74102\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current: 2 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 230 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 50 kA at 220-240 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eQuality mark: NF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection covers overload and short-circuit conditions on both AC and DC networks.\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimises energy let-through, protecting downstream equipment and wiring.\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible on upper or lower connection, simplifying distribution panel assembly.\u003c\/li\u003e\n  \u003cli\u003eTrip indicator and contact position indicator provide clear local status monitoring.\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings.\u003c\/li\u003e\n  \u003cli\u003eCircuit protection in industrial low-voltage switchgear assemblies.\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems and solar PV installations.\u003c\/li\u003e\n  \u003cli\u003eControl panels requiring compact, high-performance overcurrent protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74102, Schneider Electric A9F74102, iC60N 2A C curve MCB, Acti9 1-pole miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065511473416,"sku":"SCHA9F74102","price":6.71,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74102-miniature-circuit-breaker-mcb-acti9-ic60n-1p-2a-c-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-467085.jpg?v=1735230350"},{"product_id":"a9f74104-miniature-circuit-breaker-mcb-acti9-ic60n-1p-4a-c-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"A9F74104 Schneider MCB, Acti9 iC60N, 1P, 4A, C curve, 6000A 50kA","description":"\u003cp\u003eThe Schneider Electric A9F74104 is a 1-pole miniature circuit breaker from the Acti 9 iC60N series, rated 4A with a C tripping curve. Its thermomagnetic protection unit delivers a breaking capacity of 6000A at 230V AC (EN\/IEC 60898-1) and 50 kA at 220-240V AC (EN\/IEC 60947-2), compatible with both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74104\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current: 4A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000A at 230V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 50 kA at 220-240V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at up to 72V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eUsage category: A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for clear local signaling\u003c\/li\u003e\n  \u003cli\u003eUpper or lower comb busbar connection supported for flexible wiring\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 for effective energy limiting during short-circuit events\u003c\/li\u003e\n  \u003cli\u003eNF quality certified for assured compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCircuit protection in residential and commercial final distribution boards\u003c\/li\u003e\n  \u003cli\u003eIndustrial control and automation panels on AC networks\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery-backed systems\u003c\/li\u003e\n  \u003cli\u003eCompact DIN rail switchboards and distribution panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74104, Schneider Electric A9F74104, iC60N 1P 4A C curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065512685832,"sku":"SCHA9F74104","price":5.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74104-miniature-circuit-breaker-mcb-acti9-ic60n-1p-4a-c-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-506698.jpg?v=1735230356"},{"product_id":"a9f74106-ic60n-miniature-circuit-breaker-1p-6a-c-curve","title":"Schneider A9F74106 Acti9 iC60N MCB 1P 6 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74106 is a 1-pole 6 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, with a C tripping curve and thermomagnetic trip technology for protection on both AC and DC distribution networks. Breaking capacity is 6,000 A Icn at 230 V AC per EN\/IEC 60898-1 and 10 kA Icu at 220-240 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74106\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 6 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6,000 A at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 7,500 A (75%) at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (upper or lower), 1-25 mm² rigid \/ 1-16 mm² flexible; strip length 14 mm; torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic trip unit provides reliable protection against both overload and short-circuit faults\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003eTrip indicator and contact position indicator allow quick local fault diagnosis\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimises let-through energy during short-circuit events\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and light commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting, socket-outlet, and small appliance circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and switchboard assemblies\u003c\/li\u003e\n  \u003cli\u003eDC distribution in renewable energy and battery storage systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74106, Schneider Electric A9F74106, iC60N 6A C curve MCB, Acti9 1P 6A miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065512882440,"sku":"SCHA9F74106","price":3.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74106-ic60n-miniature-circuit-breaker-1p-6a-c-curve-298514.jpg?v=1735230349"},{"product_id":"a9f74110-miniature-circuit-breaker-mcb-acti9-ic60n-1p-10a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74110 Acti9 iC60N MCB 1P 10 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74110 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, designed for electrical power distribution. It provides thermomagnetic protection with a C tripping curve and a rated current of 10 A, suitable for both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74110\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 10 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 72 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 15 kA at 12-60 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-2, EN 60947-2, EN 60898-1, IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection with C curve for reliable overload and short-circuit detection\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks, offering installation flexibility\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible from top or bottom for simplified distribution board wiring\u003c\/li\u003e\n  \u003cli\u003eTrip position indicator and handle-operated control for clear status visibility\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70 °C for demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial electrical installations\u003c\/li\u003e\n  \u003cli\u003eProtection of circuits in industrial control panels and switchgear\u003c\/li\u003e\n  \u003cli\u003eDC applications in photovoltaic and battery-backed systems (up to 72 V DC)\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting, socket, and small power circuits\u003c\/li\u003e\n  \u003cli\u003eLow-voltage panel assemblies requiring compact DIN rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-2, EN 60947-2, EN 60898-1, and IEC 60898-1. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74110, Schneider Electric A9F74110, Acti9 iC60N 10A MCB, Schneider 1-pole 10A C-curve circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065513701640,"sku":"SCHA9F74110","price":3.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74110-miniature-circuit-breaker-mcb-acti9-ic60n-1p-10a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-181659.jpg?v=1735230355"},{"product_id":"a9f74116-miniature-circuit-breaker-mcb-acti9-ic60n-1p-16a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74116 Acti9 iC60N MCB 1P 16 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74116 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 16 A with a C tripping curve. It delivers thermomagnetic overcurrent protection for AC and DC networks, achieving 6,000 A Icn at 230 V AC per EN\/IEC 60898-1 and 10 kA Icu at 220-240 V AC per EN\/IEC 60947-2. Approved for use as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74116\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current: 16 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1-25 mm² solid \/ 1-16 mm² flexible (upper or lower)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStandards: EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection unit delivers reliable overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eC tripping curve designed for loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eApproved as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting with comb busbar connection block support (upper or lower)\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance of 20,000 cycles and electrical endurance of 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection in electrical distribution panels\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in solar and battery storage installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74116, Schneider Electric A9F74116, Acti9 iC60N 16A MCB, 1-pole C curve miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065513767176,"sku":"SCHA9F74116","price":2.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74116-miniature-circuit-breaker-mcb-acti9-ic60n-1p-16a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-504841.jpg?v=1735230353"},{"product_id":"a9f74120-ic60n-miniature-circuit-breaker-1p-20a-c-curve","title":"Schneider A9F74120 Acti9 iC60N MCB 1P 20 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74120 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 20 A with a C tripping curve. It provides thermomagnetic overcurrent protection for AC and DC networks, with a breaking capacity of 6,000 A Icn at 230 V AC per EN\/IEC 60898-1 and 10 kA Icu at 220-240 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74120\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 20 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 230 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 220-240 V AC 50\/60 Hz; 36 kA at 12-60 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1-25 mm² rigid \/ 1-16 mm² flexible; tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles; electrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection unit operates across both AC and DC networks\u003c\/li\u003e\n  \u003cli\u003eTrip indicator enables quick local fault identification\u003c\/li\u003e\n  \u003cli\u003eContact position indicator provides clear open\/closed status at a glance\u003c\/li\u003e\n  \u003cli\u003eCompatible with upper or lower comb busbar distribution blocks\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy and protects downstream equipment\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control and automation panels with AC or DC supply\u003c\/li\u003e\n  \u003cli\u003eLow-voltage electrical energy distribution systems\u003c\/li\u003e\n  \u003cli\u003eDIN rail enclosures requiring compact single-pole circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74120, Schneider Electric A9F74120, iC60N 20A C curve MCB, Acti9 1-pole 20A miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065513898248,"sku":"SCHA9F74120","price":2.97,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74120-ic60n-miniature-circuit-breaker-1p-20a-c-curve-205914.jpg?v=1735230354"},{"product_id":"a9f74125-miniature-circuit-breaker-mcb-acti9-ic60n-1p-25a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74125 Acti9 iC60N MCB 1P 25 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74125 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 25 A with a C tripping curve. It provides thermal-magnetic protection for AC and DC distribution circuits with a breaking capacity of 10 kA at 220-240 V AC under IEC\/EN 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74125\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 25 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 230 V AC 50\/60 Hz (EN\/IEC 60898-1); 10 kA Icu at 220-240 V AC 50\/60 Hz (EN\/IEC 60947-2); 10 kA Icu at 72 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve thermal-magnetic trip unit suitable for loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks (top or bottom)\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for quick visual diagnostics\u003c\/li\u003e\n  \u003cli\u003eCompact 18 mm width optimises space in distribution boards\u003c\/li\u003e\n  \u003cli\u003eRated for both AC and DC networks, expanding installation flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal circuit protection in residential and commercial electrical distribution boards\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and socket outlet circuits in buildings\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery storage installations\u003c\/li\u003e\n  \u003cli\u003eIndustrial panel boards requiring compact DIN rail mounted overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74125, Schneider Electric A9F74125, iC60N 1P 25A C curve MCB, Acti9 miniature circuit breaker 25A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065514651912,"sku":"SCHA9F74125","price":3.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74125-miniature-circuit-breaker-mcb-acti9-ic60n-1p-25a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-783447.jpg?v=1735230357"},{"product_id":"a9f74132-ic60n-miniature-circuit-breaker-1p-32a-c-curve","title":"Schneider A9F74132 Acti9 iC60N MCB 1P 32 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74132 is a single-pole 32 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, providing thermomagnetic overcurrent protection with a C tripping characteristic. It delivers a breaking capacity of 10 kA at 220-240 V AC per IEC 60947-2, making it suitable for high-demand distribution applications. Compatible with both AC and DC networks, it is certified as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74132\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 32 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTripping unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eOvercurrent trip threshold: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-35 mm² rigid \/ 1-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection delivers reliable overload and short-circuit response in a single compact device.\u003c\/li\u003e\n  \u003cli\u003eApproved as an isolating device, eliminating the need for a separate isolator in many installations.\u003c\/li\u003e\n  \u003cli\u003eVisual trip indicator and contact position indicator provide immediate local fault status feedback.\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block compatible at top or bottom, simplifying multi-circuit panel wiring.\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 design reduces let-through energy, protecting downstream equipment from thermal stress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings.\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and socket-outlet circuits in low-voltage panels.\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection in industrial control and automation panels.\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery-backed systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74132, Schneider Electric A9F74132, iC60N 32A C curve MCB, Acti9 1P 32A breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515143432,"sku":"SCHA9F74132","price":4.07,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74132-ic60n-miniature-circuit-breaker-1p-32a-c-curve-947496.jpg?v=1735230349"},{"product_id":"a9f74140-miniature-circuit-breaker-mcb-acti9-ic60n-1p-40a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74140 Acti9 iC60N MCB 1P 40 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74140 is a 1-pole, 40 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, designed for electrical distribution on AC and DC networks. Its thermomagnetic C tripping curve and ultimate breaking capacity (Icu) of 10 kA at 220-240 V AC per IEC 60947-2 make it a reliable solution for general-purpose circuit protection in residential and commercial installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74140\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P; rated current: 40 A; tripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC; protection technology: thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 230 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 220-240 V AC 50\/60 Hz; 10 kA at 72 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7.5 kA at 220-240 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1); use category: A (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz; impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed; dimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg; color: white; IP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70°C; storage temperature: -40...85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1...35 mm² rigid \/ 1...25 mm² flexible; strip length: 14 mm; tightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV; pollution degree: 3; tropicalization: 2 (IEC 60068-1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve thermomagnetic protection suited to loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eDual AC and DC network compatibility in a single device\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimizes let-through energy, protecting downstream equipment\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator enables fast local fault identification\u003c\/li\u003e\n  \u003cli\u003eUpper or lower comb busbar block compatibility for flexible panel wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems up to 72 V\u003c\/li\u003e\n  \u003cli\u003eCircuits requiring overvoltage category IV protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74140, Schneider Electric A9F74140, iC60N 40A C curve MCB, Acti9 1-pole 40 amp circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515176200,"sku":"SCHA9F74140","price":5.06,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74140-miniature-circuit-breaker-mcb-acti9-ic60n-1p-40a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-631908.jpg?v=1735230349"},{"product_id":"a9f74150-miniature-circuit-breaker-mcb-acti9-ic60n-1p-50a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74150 Acti9 iC60N MCB 1P 50 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74150 is a 1-pole 50 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, equipped with a C tripping curve and thermomagnetic protection technology. It delivers a breaking capacity of 10 kA at 220-240 V AC per IEC 60947-2 and is rated for both AC and DC network applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74150\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current: 50 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 230 V AC 50\/60 Hz (IEC 60898-1); 10 kA Icu at 220-240 V AC 50\/60 Hz (IEC 60947-2); 15 kA Icu at 12-60 V DC (IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-35 mm² rigid \/ 1-25 mm² flexible; strip length 14 mm; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60898-1, IEC 60947-2, EN 60898-1, EN 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eApproved for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with busbar comb distribution systems, upper or lower connection, 9 mm pitch\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator for clear local fault signalling\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category IV and pollution degree 3 for demanding industrial environments\u003c\/li\u003e\n  \u003cli\u003eTropicalization class 2 per IEC 60068-1 for high-humidity conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eSub-distribution and industrial panels requiring high breaking capacity\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery storage systems\u003c\/li\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection for cables and connected equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, IEC 60947-2, EN 60898-1, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74150, Schneider Electric A9F74150, iC60N 1P 50A MCB, 1-pole 50 A C curve miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515241736,"sku":"SCHA9F74150","price":8.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74150-miniature-circuit-breaker-mcb-acti9-ic60n-1p-50a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-384202.jpg?v=1735230357"},{"product_id":"a9f74163-ic60n-miniature-circuit-breaker-1p-63a-c-curve","title":"Schneider A9F74163 Acti9 iC60N MCB 1P 63 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74163 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 63 A with a C tripping curve for thermomagnetic overload and short-circuit protection. Compatible with both AC and DC networks, it delivers a breaking capacity of 10 kA at 220-240 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74163\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eRated current: 63 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 230 V AC 50\/60 Hz (IEC\/EN 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 220-240 V AC; 36 kA at 12-60 V AC; 15 kA at 12-60 V DC; 10 kA at 72 V DC (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7.5 kA at 220-240 V AC; 27 kA at 12-60 V AC (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC 50\/60 Hz (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eUse category: A (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 18 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3 (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-35 mm² rigid \/ 1-25 mm² flexible; strip length 14 mm; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection technology responds reliably to both sustained overloads and short-circuit faults\u003c\/li\u003e\n  \u003cli\u003eRated for use as an isolating device per IEC\/EN 60898-1 and IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible (upper or lower connection) for straightforward distribution board assembly\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy, protecting downstream components and wiring\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator provide clear local circuit status monitoring\u003c\/li\u003e\n  \u003cli\u003eSuitable for DC networks including up to 72 V DC, broadening installation flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial switchboards and control panels\u003c\/li\u003e\n  \u003cli\u003eDC power distribution in renewable energy and battery storage systems\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring overvoltage category IV and pollution degree 3 compliance\u003c\/li\u003e\n  \u003cli\u003eCircuits where class 3 energy limitation is needed to safeguard sensitive downstream equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 60898-1 and IEC\/EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74163, Schneider Electric A9F74163, iC60N 1P 63A C curve MCB, Acti9 miniature circuit breaker 63A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515307272,"sku":"SCHA9F74163","price":9.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74163-ic60n-miniature-circuit-breaker-1p-63a-c-curve-289156.jpg?v=1735230426"},{"product_id":"a9f74202-miniature-circuit-breaker-mcb-acti9-ic60n-2p-2a-c-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F74202 Acti9 iC60N MCB 2P 2 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74202 is a 2-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 2 A with a C tripping curve. Designed for electrical power distribution, it provides thermomagnetic overcurrent protection on both AC and DC networks with a breaking capacity up to 50 kA at 380-415 V AC per IEC\/EN 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74202\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current: 2 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC (EN\/IEC 60898-1); 50 kA Icu at 220-415 V AC (EN\/IEC 60947-2); 10 kA Icu at 72-125 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 50 kA 100% at 380-415 V AC\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60898-1, EN 60898-1, IEC 60947-2, EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eQuality marks: NF\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic trip unit provides reliable overload and short-circuit protection on AC and DC networks\u003c\/li\u003e\n  \u003cli\u003eHigh breaking capacity of 50 kA Icu (IEC\/EN 60947-2) ensures suitability for demanding industrial installations\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimises let-through energy, reducing stress on downstream equipment\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible (upper or lower) for simplified distribution board wiring\u003c\/li\u003e\n  \u003cli\u003eTrip position indicator and handle-operated local signalling for quick fault identification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring IEC 60947-2 rated devices\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic or battery backup systems (up to 125 V DC)\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection for sensitive loads requiring low let-through energy (class 3)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74202, Schneider Electric A9F74202, Acti9 iC60N 2A 2P C curve MCB, Schneider 2A C curve miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515340040,"sku":"SCHA9F74202","price":14.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74202-miniature-circuit-breaker-mcb-acti9-ic60n-2p-2a-c-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-138301.jpg?v=1735230419"},{"product_id":"a9f74204-miniature-circuit-breaker-mcb-acti9-ic60n-2p-4a-c-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F74204 Acti9 iC60N MCB 2P 4 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74204 is a 2-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 4 A with a C tripping curve. It delivers thermomagnetic overcurrent protection for AC and DC networks, offering up to 50 kA breaking capacity at 380-415 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74204\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P (2 protected)\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 4 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 400 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 50 kA at 380-415 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eConnection: single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible (upper or lower)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eQuality marks: NF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC tripping curve suited to general distribution circuits with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eApproved for use as an isolation device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 for high energy-limiting performance\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator for quick local fault identification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and light commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring compact MCB overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eLow-voltage AC and DC distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74204, Schneider Electric A9F74204, iC60N 2P 4A C curve MCB, Acti 9 iC60N C4.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515471112,"sku":"SCHA9F74204","price":14.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9f74204-miniature-circuit-breaker-mcb-acti9-ic60n-2p-4a-c-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-2692843.jpg?v=1757426565"},{"product_id":"a9f74206-ic60n-miniature-circuit-breaker-2p-6a-c-curve","title":"Schneider A9F74206 Acti9 iC60N MCB 2P 6 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74206 is a 2-pole, 6 A thermomagnetic miniature circuit breaker (MCB) from the Acti 9 iC60N range, designed for overcurrent protection in AC and DC electrical distribution networks. Its C tripping curve delivers a breaking capacity of 10 kA Icu at 380-415 V AC per IEC 60947-2 and 6,000 A Icn at 400 V AC per IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74206\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 6 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6,000 A Icn at 400 V AC (IEC\/EN 60898-1); 10 kA Icu at 380-415 V AC; 20 kA Icu at 220-240 V AC (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (IEC\/EN 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1-25 mm² rigid \/ 1-16 mm² flexible; strip length 14 mm; tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eTrip indicator for local signaling of fault conditions\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 provides energy-limiting performance to reduce downstream damage\u003c\/li\u003e\n  \u003cli\u003eTropicalization class 2 and 95% relative humidity rating support use in demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and power distribution switchboards\u003c\/li\u003e\n  \u003cli\u003eDIN rail-mounted circuit protection in automation enclosures\u003c\/li\u003e\n  \u003cli\u003eAC and DC system overcurrent protection up to 415 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74206, Schneider Electric A9F74206, iC60N 2P 6A C curve MCB, Acti9 miniature circuit breaker 6A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515569416,"sku":"SCHA9F74206","price":8.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74206-ic60n-miniature-circuit-breaker-2p-6a-c-curve-345059.jpg?v=1735230418"},{"product_id":"a9f74210-ic60n-miniature-circuit-breaker-2p-10a-c-curve","title":"Schneider A9F74210 Acti9 iC60N MCB 2P 10 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74210 is a 2-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 10 A with a C tripping curve. Designed for electrical power distribution, it delivers a breaking capacity of 10 kA at 380-415 V AC and supports both AC and DC network types with thermomagnetic protection technology.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74210\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 10 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220-240 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 125 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 36 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² solid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-2, EN 60947-2, IEC 60898-1, EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve thermomagnetic protection for reliable overload and short-circuit response in standard distribution applications\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible (top or bottom), simplifying multi-device panel wiring\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for quick status identification\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-35 to 70 °C) suitable for demanding environments\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 for reduced let-through energy during fault events\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring reliable overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eProtection of circuits in electrical power distribution systems\u003c\/li\u003e\n  \u003cli\u003eDC network applications such as photovoltaic or battery-backed systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74210, Schneider Electric A9F74210, iC60N 2P 10A MCB, Acti9 miniature circuit breaker 10A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515602184,"sku":"SCHA9F74210","price":7.97,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/schneider-electric-a9f74210-10a-2-pole-miniature-circuit-breaker-mcb-400v-type-c-curve-6848754.jpg?v=1757426566"},{"product_id":"a9f74302-miniature-circuit-breaker-mcb-acti9-ic60n-3p-2a-c-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F74302 Acti9 iC60N MCB 3P 2 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74302 is an Acti 9 iC60N 3-pole miniature circuit breaker (MCB) rated at 2 A with a C tripping curve, designed for overcurrent protection in AC and DC low-voltage distribution systems. It delivers a breaking capacity of 6,000 A Icn at 400 V AC per IEC 60898-1 and up to 50 kA Icu at 380-415 V AC per IEC 60947-2, combining high performance with a compact DIN rail footprint.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74302\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P (3 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current: 2 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 50 kA at 380-415 V AC, 25 kA at 440 V AC, 10 kA at up to 180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 50 kA (100%) at 380-415 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eUtilization category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail (fixed)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eQuality mark: NF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower connection\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator provides local fault signaling\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 ensures high energy limitation for downstream component protection\u003c\/li\u003e\n  \u003cli\u003eOperates on both AC and DC networks\u003c\/li\u003e\n  \u003cli\u003ePollution degree 3 and overvoltage category IV rating for demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection in final distribution boards for residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial electrical panels and low-voltage switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eCable and equipment protection in building services installations\u003c\/li\u003e\n  \u003cli\u003eAC and DC distribution systems requiring high breaking capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74302, Schneider Electric A9F74302, iC60N 3P 2A C curve MCB, Acti9 miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515634952,"sku":"SCHA9F74302","price":19.61,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74302-miniature-circuit-breaker-mcb-acti9-ic60n-3p-2a-c-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-719809.jpg?v=1735230426"},{"product_id":"a9f74304-miniature-circuit-breaker-mcb-acti9-ic60n-3p-4a-c-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F74304 Acti9 iC60N MCB 3P 4 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74304 is a 3-pole 4 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, fitted with a C tripping curve and thermomagnetic protection. It operates on both AC and DC networks with a breaking capacity of 50 kA Icu at 380-415 V AC per IEC\/EN 60947-2, making it a high-performance choice for demanding distribution applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74304\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 4 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6,000 A Icn at 400 V AC (IEC\/EN 60898-1); 50 kA Icu at 380-415 V AC (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 50 kA (100%) at 380-415 V AC per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per IEC\/EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible: Yes (upper or lower)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection suitable for both AC and DC distribution systems\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity of 50 kA Icu at 380-415 V AC for robust short-circuit protection in high-demand installations\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimises peak let-through current, protecting downstream equipment\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator enable fast visual status checks\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks for flexible, space-efficient panel wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial switchgear assemblies and control panels\u003c\/li\u003e\n  \u003cli\u003eDC and mixed AC\/DC power distribution systems\u003c\/li\u003e\n  \u003cli\u003eCable and circuit protection where high breaking capacity is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74304, Schneider Electric A9F74304, iC60N 3-pole MCB 4A, Acti9 miniature circuit breaker C curve.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065516421384,"sku":"SCHA9F74304","price":18.85,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74304-miniature-circuit-breaker-mcb-acti9-ic60n-3p-4a-c-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-100258.jpg?v=1735230425"},{"product_id":"a9f74306-ic60n-miniature-circuit-breaker-3p-6a-c-curve","title":"Schneider A9F74306 Acti9 iC60N MCB 3P 6 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74306 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 6 A with a C tripping curve. Designed for AC and DC power distribution networks, it delivers thermomagnetic overcurrent and short-circuit protection with a breaking capacity of 10 kA Icu at 380-415 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74306\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current: 6 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-25 mm² rigid \/ 1-16 mm² flexible conductor\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection for reliable response to both overload and short-circuit conditions\u003c\/li\u003e\n  \u003cli\u003eC tripping curve suited for loads with moderate inrush currents such as lighting and general wiring\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator for quick local fault identification\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003ePollution degree 3 and overvoltage category IV rating for demanding installation environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial power distribution and control panels\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and socket outlet circuits\u003c\/li\u003e\n  \u003cli\u003eAutomation and switchgear panel protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74306, Schneider Electric A9F74306, iC60N 3P 6A C curve MCB, Acti9 3-pole miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065516519688,"sku":"SCHA9F74306","price":12.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74306-ic60n-miniature-circuit-breaker-3p-6a-c-curve-460798.jpg?v=1735230426"},{"product_id":"a9f74310-miniature-circuit-breaker-mcb-acti9-ic60n-3p-10a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74310 Acti9 iC60N MCB 3P 10 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74310 is a 3-pole 10 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, providing overcurrent and short-circuit protection for AC and DC distribution systems. Equipped with a C tripping curve and thermomagnetic protection technology, it delivers a breaking capacity of 10 kA at 380-415 V AC per IEC 60947-2 and 6000 A Icn at 400 V AC per IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74310\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 10 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7.5 kA at 380-415 V AC 50\/60 Hz per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1-25 mm² rigid \/ 1-16 mm² flexible (upper or lower)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-2, IEC 60898-1, EN 60947-2, EN 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection provides reliable response to both overload and short-circuit conditions\u003c\/li\u003e\n  \u003cli\u003eC tripping curve with overcurrent limit at 8 x In, suited to loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eCompatible with upper or lower comb busbar distribution blocks for flexible panel wiring\u003c\/li\u003e\n  \u003cli\u003eTrip indicator gives immediate local signaling of fault conditions\u003c\/li\u003e\n  \u003cli\u003eSuitable for both AC and DC networks, including DC applications up to 180 V\u003c\/li\u003e\n  \u003cli\u003ePollution degree 3 rating supports use in industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of resistive and moderately inductive loads in switchboards and panel assemblies\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and machine protection circuits\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems requiring IEC 60947-2 rated protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-2, IEC 60898-1, EN 60947-2, and EN 60898-1. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74310, Schneider Electric A9F74310, iC60N 3P 10A C curve MCB, Acti 9 miniature circuit breaker 3 pole 10 A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065516617992,"sku":"SCHA9F74310","price":11.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74310-miniature-circuit-breaker-mcb-acti9-ic60n-3p-10a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-855772.jpg?v=1735230418"},{"product_id":"a9f74313-miniature-circuit-breaker-mcb-acti9-ic60n-3p-13a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74313 Acti9 iC60N MCB 3P 13 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74313 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 13 A with a C tripping curve. It provides thermomagnetic overload and short-circuit protection for AC and DC distribution networks, with a breaking capacity of 10 kA at 380-415 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74313\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P, 3 protected poles\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 13 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC per EN\/IEC 60898-1; 10 kA Icu at 380-415 V AC per EN\/IEC 60947-2; 20 kA Icu at 220-240 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-25 mm² rigid \/ 1-16 mm² flexible; strip length 14 mm; tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles; electrical durability: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve thermomagnetic protection with overcurrent trip threshold at 8 x In (+\/- 20%)\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower connection\u003c\/li\u003e\n  \u003cli\u003eBuilt-in trip indicator and contact position indicator for fast fault identification\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70°C suits demanding installation environments\u003c\/li\u003e\n  \u003cli\u003eTropicalization class 2 per IEC 60068-1, rated for 95% relative humidity at 55°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eOutgoing circuit protection in main and sub-distribution panels\u003c\/li\u003e\n  \u003cli\u003eMotor and equipment circuit protection in automation and control panel assemblies\u003c\/li\u003e\n  \u003cli\u003eAC and DC distribution systems requiring compact DIN rail-mounted overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-2, EN 60947-2, IEC 60898-1, and EN 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74313, Schneider Electric A9F74313, Acti9 iC60N 3-pole MCB 13A C curve.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065516650760,"sku":"SCHA9F74313","price":10.12,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74313-miniature-circuit-breaker-mcb-acti9-ic60n-3p-13a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-253835.jpg?v=1735230419"},{"product_id":"a9f74316-ic60n-miniature-circuit-breaker-3p-16a-c-curve","title":"Schneider A9F74316 Acti9 iC60N MCB 3P 16 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74316 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 16 A with a C tripping curve. Designed for electrical power distribution, it provides reliable overcurrent protection with a breaking capacity of 10 kA at 380-415 V AC, suitable for both AC and DC network types.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74316\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current: 16 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at up to 180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95 % at 55 °C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC tripping curve provides reliable protection for loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks for versatile installation\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block connection available from top or bottom terminals\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for fast fault diagnosis\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70 °C for demanding environments\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of branch circuits in electrical panels and switchboards\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring AC and DC circuit protection\u003c\/li\u003e\n  \u003cli\u003ePower distribution systems with comb busbar arrangements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74316, Schneider Electric A9F74316, Schneider iC60N 3P 16A MCB, Acti9 miniature circuit breaker C curve.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065516716296,"sku":"SCHA9F74316","price":10.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74316-ic60n-miniature-circuit-breaker-3p-16a-c-curve-757964.jpg?v=1735230426"},{"product_id":"a9f74320-ic60n-miniature-circuit-breaker-3p-20a-c-curve","title":"Schneider A9F74320 Acti9 iC60N MCB 3P 20 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74320 is a 3-pole, 20 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, designed for electrical power distribution on AC and DC networks. Its thermomagnetic protection unit and C tripping curve deliver a breaking capacity of 10 kA at 380-415 V AC and 20 kA at 220-240 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74320\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003ePoles: 3P, 3 protected poles\u003c\/li\u003e\n  \u003cli\u003eRated current: 20 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC (EN\/IEC 60898-1); 10 kA Icu at 380-415 V AC; 20 kA Icu at 220-240 V AC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eTerminal connection: 1-25 mm² rigid \/ 1-16 mm² flexible, tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection with C tripping curve for reliable overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity up to 10 kA at 380-415 V AC for demanding distribution applications\u003c\/li\u003e\n  \u003cli\u003eSuitable for both AC and DC networks, supporting a wide range of installations\u003c\/li\u003e\n  \u003cli\u003eBuilt-in trip indicator for rapid local fault identification\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting with upper or lower busbar comb distributor compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eCircuit protection in electrical panel assemblies and switchboards\u003c\/li\u003e\n  \u003cli\u003eIndustrial control and automation panels\u003c\/li\u003e\n  \u003cli\u003eAC and DC power distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74320, Schneider Electric A9F74320, iC60N 3P 20A C curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065516847368,"sku":"SCHA9F74320","price":10.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74320-ic60n-miniature-circuit-breaker-3p-20a-c-curve-399182.jpg?v=1735230417"},{"product_id":"a9f74325-miniature-circuit-breaker-mcb-acti9-ic60n-3p-25a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74325 Acti9 iC60N MCB 3P 25 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74325 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 25 A with a type C tripping curve. It delivers thermomagnetic overcurrent protection for AC and DC distribution networks, with a breaking capacity of 10 kA Icu at 380-415 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74325\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60N\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 25 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 20 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 380-415 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at up to 180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 7.5 kA (75%) at 380-415 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection operates on both AC and DC networks for broad application flexibility\u003c\/li\u003e\n  \u003cli\u003eType C tripping curve suits circuits with moderate inrush currents such as transformers and motors\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy to protect downstream components\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003eBuilt-in trip indicator provides immediate local fault signalization\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70°C supports demanding industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of motor and transformer circuits with moderate inrush loads\u003c\/li\u003e\n  \u003cli\u003eDC distribution panels and mixed AC\/DC switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring high breaking capacity and energy limitation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74325, Schneider Electric A9F74325, Acti9 iC60N 3P 25A C curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065516945672,"sku":"SCHA9F74325","price":13.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74325-miniature-circuit-breaker-mcb-acti9-ic60n-3p-25a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-650751.jpg?v=1735230418"}],"url":"https:\/\/gabbyelectric.com\/collections\/schneider-electric-miniature-circuit-breakers.oembed?page=8","provider":"Gabby Electric","version":"1.0","type":"link"}