The Circutor TQ-6 (code M74027) is a single-phase split core current transformer with a 250/5 A transformation ratio, designed to fit conductors and busbars up to 20 x 30 mm. The core opens with a button press, allowing the unit to be clipped onto a live conductor with no need to shut off power. Rated burden is 1 VA at Class 1 and 2 VA at Class 3.
Technical specifications:
- Model: TQ-6
- Circutor code: M74027
- EAN: 8433059299866
- Transformation ratio: 250/5 A
- System: Single-phase
- Rated burden: 1 VA (Class 1), 2 VA (Class 3)
- Safety factor (SF): 10
- Maximum busbar/conductor aperture: 20 × 30 mm
- Operating voltage: 0.72 kV AC max.
- Nominal frequency: 50/60 Hz
- Insulation voltage (S1-S2): 3 kV
- Thermal short-circuit current (Ith): 60 In
- Dynamic current (Idyn): 2.5 Ith
- Overall dimensions (W × H × D): 80 × 98.5 × 28 mm
- Enclosure: Self-extinguishing plastic, UL 94 V0
- Protection class: IP 20
- Thermal class: B (+130 °C)
- Working temperature: -5 to +40 °C
- Storage temperature: -40 to +85 °C
- Relative humidity: 15-85% (non-condensing)
- Mounting: Wall mount or DIN rail (accessory required for DIN rail)
- Weight: 0.3 kg
- Maximum installation altitude: 1000 m
- Standards: UNE-EN 61869-1, UNE-EN 61869-2, UNE 21031, UL 94
Features and benefits:
- Button-operated split core enables installation on energised conductors, eliminating the need for a planned outage.
- Accepts busbars and cables up to 20 × 30 mm, covering a broad range of standard conductor cross-sections.
- Self-extinguishing V0 plastic housing limits fire propagation in the event of an electrical fault.
- Dual-frequency rated at 50/60 Hz, suitable for European and international grid infrastructures.
- Optional DIN rail mounting accessory allows tidy integration alongside other panel-mounted equipment.
Applications:
- Current measurement and energy monitoring in single-phase circuits where supply interruption is not permitted.
- Retrofit metering on existing busbars and cable runs in industrial or commercial switchboards.
- Supplying a 5 A secondary signal to energy analysers, power meters, and protection relays.
- Non-invasive sensor installation in building energy management and sub-metering systems.
Also known as: Circutor TQ-6, TQ-6 M74027, split core current transformer 250/5A, button opening current transformer, busbar CT 20x30mm.
When sold out, you can still preorder by requesting a quote below.
Important
The images shown are for illustration purposes only and may not be an exact
representation of the product.