The Schneider Electric A9F74101 is a 1-pole, 1 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, designed for overcurrent protection in electrical power distribution systems. It combines a C tripping curve with thermomagnetic protection technology and a breaking capacity of 6000 A Icn at 230 V AC (EN/IEC 60898-1), with compatibility for both AC and DC networks.
Technical specifications:
- Commercial reference: A9F74101
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 iC60
- Number of poles: 1P
- Number of protected poles: 1
- Rated current: 1 A
- Tripping curve: C
- Protection technology: Thermomagnetic
- Network type: AC and DC
- Network frequency: 50/60 Hz
- Breaking capacity: 6000 A Icn at 230 V AC 50/60 Hz (EN/IEC 60898-1); 50 kA Icu at 220...240 V AC 50/60 Hz (EN/IEC 60947-2); 10 kA Icu at up to 72 V DC (EN/IEC 60947-2)
- Service breaking capacity [Ics]: 50 kA 100% at 220...240 V AC (EN/IEC 60947-2)
- Limitation class: 3 (EN/IEC 60898-1)
- Rated insulation voltage [Ui]: 500 V AC 50/60 Hz
- Rated impulse withstand voltage [Uimp]: 6 kV
- Usage category: Category A (EN/IEC 60947-2)
- IP protection rating: IP20 (IEC/EN 60529)
- Pollution degree: 3 (EN/IEC 60947-2)
- Overvoltage category: IV
- Operating temperature: -35...70°C
- Storage temperature: -40...85°C
- Relative humidity: 95% at 55°C
- Mounting: DIN rail, fixed
- Dimensions (WxHxD): 18 x 85 x 78.5 mm
- Weight: 0.215 kg
- Connection: Single terminal block (upper or lower), 1...25 mm² rigid / 1...16 mm² flexible
- Strip length: 14 mm
- Tightening torque: 2 N.m
- Mechanical endurance: 20,000 cycles
- Electrical endurance: 10,000 cycles
- Standards: EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2
Features and benefits:
- C tripping curve suited to loads with moderate inrush currents
- Compatible with comb busbar distribution blocks on upper or lower terminals
- Integral trip indicator provides quick local fault identification
- Suitable for use as an isolating device per EN/IEC 60898-1 and EN/IEC 60947-2
- Tropicalization class 2 (IEC 60068-1) for operation in humid environments
- Wide operating temperature range from -35 to 70°C
Applications:
- Final distribution boards in residential and light commercial buildings
- Overcurrent protection in industrial control and automation panels
- DC circuit protection in photovoltaic installations and battery systems
- Electrical power distribution in commercial facilities
Compliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.
Also known as: Schneider A9F74101, Schneider Electric A9F74101, iC60N 1 A C curve MCB, Acti 9 1-pole miniature circuit breaker.
When sold out, you can still preorder by requesting a quote below.
Important
The images shown are for illustration purposes only and may not be an exact
representation of the product.