Schneider A9F74325 Acti9 iC60N MCB 3P 25 A C Curve 10kA
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric A9F74325 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 25 A with a type C tripping curve. It delivers thermomagnetic overcurrent protection for AC and DC distribution networks, with a breaking capacity of 10 kA Icu at 380-415 V AC per EN/IEC 60947-2.
Technical specifications:
- Commercial reference: A9F74325
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 iC60
- Device short name: iC60N
- Product type: Miniature circuit breaker (MCB)
- Number of poles: 3P
- Number of protected poles: 3
- Rated current [In]: 25 A
- Tripping curve: C
- Network type: AC / DC
- Protection technology: Thermomagnetic
- Breaking capacity [Icn]: 6000 A at 400 V AC 50/60 Hz per EN/IEC 60898-1
- Breaking capacity [Icu]: 20 kA at 220-240 V AC 50/60 Hz per EN/IEC 60947-2
- Breaking capacity [Icu]: 10 kA at 380-415 V AC 50/60 Hz per EN/IEC 60947-2
- Breaking capacity [Icu]: 10 kA at up to 180 V DC per EN/IEC 60947-2
- Service breaking capacity [Ics]: 7.5 kA (75%) at 380-415 V AC per EN/IEC 60947-2
- Rated insulation voltage [Ui]: 500 V AC 50/60 Hz
- Rated impulse withstand voltage [Uimp]: 6 kV
- Limitation class: 3 per EN/IEC 60898-1
- Usage category: Category A per EN/IEC 60947-2
- Overcurrent protection limit: 8 x In +/- 20%
- Mounting: DIN rail
- Dimensions (W x H x D): 54 x 85 x 78.5 mm
- Weight: 0.375 kg
- IP protection rating: IP20 per IEC/EN 60529
- Operating temperature: -35 to 70°C
- Storage temperature: -40 to 85°C
- Connection: Single terminal block, 1-25 mm² rigid / 1-16 mm² flexible
- Strip length: 14 mm
- Tightening torque: 2 N.m
- Mechanical durability: 20,000 cycles
- Electrical durability: 10,000 cycles
- Color: White
- Warranty: 18 months
Features and benefits:
- Thermomagnetic protection operates on both AC and DC networks for broad application flexibility
- Type C tripping curve suits circuits with moderate inrush currents such as transformers and motors
- Limitation class 3 reduces let-through energy to protect downstream components
- Compatible with comb busbar distribution blocks on upper or lower terminals
- Built-in trip indicator provides immediate local fault signalization
- Wide operating temperature range of -35 to 70°C supports demanding industrial environments
Applications:
- Final distribution boards in commercial and industrial buildings
- Protection of motor and transformer circuits with moderate inrush loads
- DC distribution panels and mixed AC/DC switchgear assemblies
- Industrial control panels requiring high breaking capacity and energy limitation
Compliant with EN/IEC 60898-1 and EN/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.