{"title":"4 Pole MCB","description":"\u003cp\u003eGet maximum protection and flexibility with our \u003cstrong data-start=\"1768\" data-end=\"1782\"\u003e4 pole MCB\u003c\/strong\u003e range. Ideal for \u003cstrong data-start=\"1800\" data-end=\"1828\"\u003ethree-phase with neutral\u003c\/strong\u003e systems, these breakers offer advanced short circuit and overload protection while ensuring balanced distribution of electrical loads. Perfect for industrial, commercial, and infrastructure projects where precision and safety matter most. Built to international standards for performance you can trust.\u003c\/p\u003e","products":[{"product_id":"a9f74425-miniature-circuit-breaker-mcb-acti9-ic60n-4p-25a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74425 Acti9 iC60N MCB 4P 25 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74425 is a 4-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 25 A with a C tripping curve. Designed for electrical power distribution, it uses thermomagnetic protection technology and delivers a breaking capacity of 10 kA Icu at 380-415 V AC per IEC 60947-2 and 6,000 A Icn at 400 V AC per IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74425\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort designation: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P (4 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current: 25 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6,000 A Icn at 400 V AC (EN\/IEC 60898-1); 10 kA Icu at 380-415 V AC; 20 kA at 220-240 V AC; 10 kA at 250 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7.5 kA at 380-415 V AC; 15 kA at 220-240 V AC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 72 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-25 mm² flexible \/ 1-16 mm² rigid; strip length 14 mm; tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection for reliable overcurrent and short-circuit fault clearing\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting with comb busbar distribution block compatibility, upper or lower connection\u003c\/li\u003e\n  \u003cli\u003eTrip indicator for local fault signaling with handle operation\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 for high energy cut-off performance\u003c\/li\u003e\n  \u003cli\u003eSuitable for both AC and DC network applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial electrical power distribution panels\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection requiring 4-pole switching and isolation\u003c\/li\u003e\n  \u003cli\u003eElectrical installations demanding simultaneous disconnection of all active conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74425, Schneider Electric A9F74425, iC60N 4P 25A C curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065519141128,"sku":"SCHA9F74425","price":17.51,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74425-miniature-circuit-breaker-mcb-acti9-ic60n-4p-25a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-123964.jpg?v=1735230419"},{"product_id":"a9f74440-miniature-circuit-breaker-mcb-acti9-ic60n-4p-40a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74440 Acti9 iC60N MCB 4P 40 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74440 is a 4-pole, 40 A Miniature Circuit Breaker (MCB) from the Acti 9 iC60N series, designed for electrical energy distribution. It features a C tripping curve and a breaking capacity of 10 kA at 380-415 V AC, suitable for both AC and DC network types.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74440\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC (EN\/IEC 60898-1); 10 kA Icu at 380-415 V AC (EN\/IEC 60947-2); 10 kA Icu at up to 250 V DC (EN\/IEC 60947-2); 20 kA Icu at 220-240 V AC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 7.5 kA (75%) at 380-415 V AC; 15 kA (75%) at 220-240 V AC\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 72 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3 (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-35 mm² rigid \/ 1-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStripping length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-2, IEC 60898-1, EN 60947-2, EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for both AC and DC networks, providing flexibility across installation types\u003c\/li\u003e\n  \u003cli\u003eThermomagnetic protection technology for reliable overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indication for quick visual status checks\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks (top or bottom connection)\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 ensures high energy limitation, reducing stress on downstream equipment\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting for straightforward integration into standard distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial facilities\u003c\/li\u003e\n  \u003cli\u003eProtection of circuits in electrical energy distribution panels\u003c\/li\u003e\n  \u003cli\u003eIndustrial control cabinets requiring both AC and DC circuit protection\u003c\/li\u003e\n  \u003cli\u003eSwitchboards where high breaking capacity and energy limitation are required\u003c\/li\u003e\n  \u003cli\u003eApplications demanding reliable protection across a wide operating temperature range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-2, IEC 60898-1, EN 60947-2, and EN 60898-1. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74440, Schneider Electric A9F74440, Acti9 iC60N 4P 40A MCB, Schneider 4-pole miniature circuit breaker 40A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065519894792,"sku":"SCHA9F74440","price":18.07,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/schneider-electric-acti9-ic60n-4p-40a-mcb-a9f74440-curve-c-6ka20ka-rated-7246568.jpg?v=1757426566"},{"product_id":"a9f74402-miniature-circuit-breaker-mcb-acti9-ic60n-4p-2a-c-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F74402 Acti9 iC60N MCB 4P 2 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74402 is a 4-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 2 A with a C tripping curve. It provides thermomagnetic overcurrent protection for both AC and DC networks, with a breaking capacity up to 50 kA Icu at 380-415 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74402\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 2 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC 50\/60 Hz per EN\/IEC 60898-1; 50 kA Icu at 380-415 V AC 50\/60 Hz per EN\/IEC 60947-2; 10 kA Icu at 250 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 50 kA 100% at 380-415 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3 per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 72 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eQuality marks: NF\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for both AC and DC networks, offering flexible installation across mixed electrical systems\u003c\/li\u003e\n  \u003cli\u003eHigh breaking capacity of 50 kA Icu provides robust short-circuit protection in demanding installations\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces the energy let-through during fault conditions, protecting downstream equipment\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator provide clear local signalling of device status\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks from top or bottom, simplifying panel wiring\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial electrical installations\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring DC and AC circuit protection\u003c\/li\u003e\n  \u003cli\u003ePower distribution systems where high breaking capacity and current limitation are required\u003c\/li\u003e\n  \u003cli\u003eProtection of sensitive equipment in installations with high pollution levels (degree 3)\u003c\/li\u003e\n  \u003cli\u003eSwitchboards and enclosures with DIN rail mounting in industrial and building automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74402, Schneider Electric A9F74402, Acti9 iC60N 4P 2A MCB, Schneider 4-pole miniature circuit breaker 2A C curve.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075314086152,"sku":"SCHA9F74402","price":25.41,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74402-miniature-circuit-breaker-mcb-acti9-ic60n-4p-2a-c-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-664460.jpg?v=1735230417"},{"product_id":"a9f74404-miniature-circuit-breaker-mcb-acti9-ic60n-4p-4a-c-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F74404 Acti9 iC60N MCB 4P 4 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74404 is a 4-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 4 A with a C tripping curve. It provides thermomagnetic overcurrent protection for AC and DC distribution circuits, with a breaking capacity of 6000 A (Icn) at 400 V AC per EN\/IEC 60898-1 and up to 50 kA (Icu) at 220-415 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74404\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 4 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 50 kA at 220-415 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 250 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 50 kA 100% at 380-415 V AC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 72 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3 (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eBusbar comb compatibility: Top or bottom\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-2, EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eQuality mark: NF\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh breaking capacity of up to 50 kA (Icu) makes it suitable for demanding industrial and commercial distribution applications.\u003c\/li\u003e\n  \u003cli\u003eSuitable for both AC and DC networks, offering flexibility across a wide range of installations.\u003c\/li\u003e\n  \u003cli\u003eC tripping curve provides reliable protection for circuits with moderate inrush currents such as lighting and distribution loads.\u003c\/li\u003e\n  \u003cli\u003eTrip indicator provides local signalling for quick fault identification without additional instruments.\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbars (top or bottom) for efficient panel assembly and wiring.\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2, enabling safe maintenance disconnection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings requiring 4-pole overcurrent protection.\u003c\/li\u003e\n  \u003cli\u003eProtection of three-phase circuits with neutral in industrial panels and switchboards.\u003c\/li\u003e\n  \u003cli\u003eElectrical energy distribution systems where high breaking capacity and AC\/DC compatibility are required.\u003c\/li\u003e\n  \u003cli\u003eControl panels and enclosures requiring DIN rail mounted protection devices with compact footprint.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2 and EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74404, Schneider Electric A9F74404, Acti9 iC60N 4P 4A C curve MCB, Schneider 4-pole miniature circuit breaker 4A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075314217224,"sku":"SCHA9F74404","price":27.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74404-miniature-circuit-breaker-mcb-acti9-ic60n-4p-4a-c-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-773607.jpg?v=1735230426"},{"product_id":"a9f74406-ic60n-miniature-circuit-breaker-4p-6a-c-curve","title":"Schneider A9F74406 Acti9 iC60N MCB 4P 6 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74406 is a 4-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 6 A with a C tripping curve for electrical power distribution. It features thermomagnetic protection for AC and DC networks, with a breaking capacity of 10 kA at 380-415 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74406\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003ePoles: 4P, 4 protected poles\u003c\/li\u003e\n  \u003cli\u003eRated current: 6 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220-240 V AC; 10 kA at 380-415 V AC; 10 kA at 250 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail (fixed)\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 72 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-25 mm² rigid \/ 1-16 mm² flexible; strip length 14 mm; torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV; pollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic tripping unit provides reliable overcurrent and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003eTrip indicator enables fast local signaling of fault events\u003c\/li\u003e\n  \u003cli\u003eContact position indicator allows safe visual status verification\u003c\/li\u003e\n  \u003cli\u003eExpandable with a separate differential protection block for extended functionality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial electrical panels requiring 4-pole overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eAC and DC distribution systems requiring high breaking capacity\u003c\/li\u003e\n  \u003cli\u003eInstallations in environments with pollution degree 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74406, Schneider Electric A9F74406, iC60N 4P 6A C curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075315593480,"sku":"SCHA9F74406","price":20.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74406-ic60n-miniature-circuit-breaker-4p-6a-c-curve-999065.jpg?v=1735230426"},{"product_id":"a9f74410-miniature-circuit-breaker-mcb-acti9-ic60n-4p-10a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74410 Acti9 iC60N MCB 4P 10 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74410 is a 4-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 10 A with a C tripping curve. Designed for electrical distribution applications, it offers a breaking capacity of 10 kA at 380-415 V AC and supports both AC and DC networks. Its thermomagnetic protection technology ensures reliable overcurrent and short-circuit protection.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74410\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current: 10 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC (EN\/IEC 60898-1); 10 kA Icu at 380-415 V AC; 20 kA Icu at 220-240 V AC; 10 kA Icu at up to 250 V DC\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7.5 kA at 380-415 V AC; 15 kA at 220-240 V AC\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 72 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for both AC and DC network applications, offering broad installation flexibility\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator provide clear local status signalling\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks for simplified panel wiring (top or bottom)\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimises let-through energy during short-circuit events, protecting downstream equipment\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eTropicalisation rating 2 (IEC 60068-1) ensures reliable operation in humid environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of branch circuits in low-voltage switchgear and controlgear assemblies\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery-backed systems\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring 4-pole overcurrent and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring overvoltage category IV compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74410, Schneider Electric A9F74410, iC60N 4P 10A C curve MCB, Acti9 4-pole miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075316052232,"sku":"SCHA9F74410","price":16.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74410-miniature-circuit-breaker-mcb-acti9-ic60n-4p-10a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-201207.jpg?v=1735230426"},{"product_id":"a9f74416-miniature-circuit-breaker-mcb-acti9-ic60n-4p-16a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74416 Acti9 iC60N MCB 4P 16 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74416 is a 4-pole 16 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, featuring a C tripping curve for thermomagnetic overcurrent protection. Compatible with both AC and DC networks, it delivers a breaking capacity of 10 kA Icu at 380-415 V AC and 20 kA Icu at 220-240 V AC per IEC\/EN 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74416\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current: 16 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC per IEC\/EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC; 20 kA at 220-240 V AC; 10 kA at max. 250 V DC per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 72 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: single terminal block, 1-25 mm² solid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003eBuilt-in trip indicator for local fault signalization\u003c\/li\u003e\n  \u003cli\u003eTropicalization class 2 per IEC 60068-1 for high-humidity environments\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70°C for demanding installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection in 4-pole AC and DC distribution systems\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring combined isolation and circuit protection\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring high energy limitation with class 3 performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74416, Schneider Electric A9F74416, iC60N 4-pole MCB, Acti9 4P miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075316150536,"sku":"SCHA9F74416","price":15.37,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74416-miniature-circuit-breaker-mcb-acti9-ic60n-4p-16a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-269899.jpg?v=1735230418"},{"product_id":"a9f74420-miniature-circuit-breaker-mcb-acti9-ic60n-4p-20a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74420 Acti9 iC60N MCB 4P 20 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74420 is a 4-pole, 20 A miniature circuit breaker from the Acti 9 iC60N series, providing overload and short-circuit protection in electrical distribution systems. Its thermomagnetic protection unit operates on a C tripping curve, with a breaking capacity of 10 kA at 380-415 V AC per IEC\/EN 60947-2, suitable for use on both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74420\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P, 4 protected poles\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 20 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC; 20 kA at 220-240 V AC; 10 kA at 180-250 V DC (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 72 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1-25 mm² rigid \/ 1-16 mm² flexible, tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60898-1, EN 60898-1, IEC 60947-2, EN 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection unit ensures reliable overload and short-circuit interruption\u003c\/li\u003e\n  \u003cli\u003eC tripping curve suited to standard loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eUpper or lower comb busbar connection supports flexible panel wiring configurations\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator enable rapid fault identification\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and residential buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring 4-pole short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eProtection of circuits in AC and DC electrical distribution systems\u003c\/li\u003e\n  \u003cli\u003eDIN rail switchgear assemblies in industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74420, Schneider Electric A9F74420, iC60N 4P 20A C curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075316183304,"sku":"SCHA9F74420","price":15.71,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74420-miniature-circuit-breaker-mcb-acti9-ic60n-4p-20a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-305317.jpg?v=1735230418"},{"product_id":"a9f74432-miniature-circuit-breaker-mcb-acti9-ic60n-4p-32a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74432 Acti9 iC60N MCB 4P 32 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74432 is a 4-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 32 A with a C tripping curve. Designed for electrical power distribution, it provides thermomagnetic overload and short-circuit protection with a breaking capacity of 10 kA at 380-415 V AC, suitable for both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74432\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current: 32 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC per EN\/IEC 60898-1; 10 kA Icu at 380-415 V AC per EN\/IEC 60947-2; 10 kA Icu at ≤250 V DC per EN\/IEC 60947-2; 20 kA Icu at 220-240 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7.5 kA (75%) at 380-415 V AC; 15 kA (75%) at 220-240 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 72 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-35 mm² rigid \/ 1-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC tripping curve suited for loads with moderate inrush currents such as resistive and inductive equipment\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy, minimizing damage to downstream equipment during faults\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2, enabling safe maintenance switching\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on top or bottom connections for flexible panel wiring\u003c\/li\u003e\n  \u003cli\u003eTrip indication via built-in trip indicator for quick fault identification\u003c\/li\u003e\n  \u003cli\u003eOperates on both AC and DC networks, providing installation flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of circuits in electrical distribution panels requiring high breaking capacity\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels with mixed AC and DC supply architectures\u003c\/li\u003e\n  \u003cli\u003eProtection of cables and equipment in low-voltage power distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74432, Schneider Electric A9F74432, iC60N 4P 32A MCB, Acti9 miniature circuit breaker 32A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075316248840,"sku":"SCHA9F74432","price":17.52,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/schneider-electric-acti9-ic60n-4p-32a-mcb-a9f74432-curve-c-6ka10ka-rated-3223606.jpg?v=1757426448"},{"product_id":"a9f74450-miniature-circuit-breaker-mcb-acti9-ic60n-4p-50a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74450 Acti9 iC60N MCB 4P 50 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74450 is a 4-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 50 A with a C tripping curve. Designed for AC and DC distribution systems, it delivers thermomagnetic overcurrent protection with a breaking capacity of 10 kA Icu at 380-415 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74450\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P (4 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current: 50 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC; 20 kA at 220-240 V AC; 10 kA at up to 250 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent trip level: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 72 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-35 mm² rigid \/ 1-25 mm² flexible; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for use as an isolation device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator provides local fault signalling without additional accessories\u003c\/li\u003e\n  \u003cli\u003eSupports both AC and DC networks for flexible installation in mixed systems\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category IV and pollution degree 3 rating for demanding industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial electrical installations\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection in industrial switchgear and control panels\u003c\/li\u003e\n  \u003cli\u003e4-pole circuit protection in AC and DC power distribution systems\u003c\/li\u003e\n  \u003cli\u003eInstallations in high-humidity environments, rated for 95% relative humidity at 55°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74450, Schneider Electric A9F74450, iC60N 4P 50A C curve MCB, Acti9 4-pole miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075316281608,"sku":"SCHA9F74450","price":31.17,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74450-miniature-circuit-breaker-mcb-acti9-ic60n-4p-50a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-979391.jpg?v=1735230426"},{"product_id":"a9f74463-miniature-circuit-breaker-mcb-acti9-ic60n-4p-63a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74463 Acti9 iC60N MCB 4P 63 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74463 is a 4-pole 63 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, designed for overcurrent and short-circuit protection in AC and DC distribution systems. Its thermomagnetic protection unit with a type C tripping curve delivers a rated ultimate breaking capacity of 10 kA at 380-415 V AC per IEC 60947-2 and is approved for use as an isolating device.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74463\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P (4 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 63 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eRated breaking capacity [Icn]: 6000 A at 400 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eUltimate breaking capacity [Icu]: 10 kA at 380-415 V AC; 20 kA at 220-240 V AC; 10 kA at up to 250 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 72 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-35 mm² rigid \/ 1-25 mm² flexible; strip length 14 mm; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection for reliable defense against overloads and short circuits\u003c\/li\u003e\n  \u003cli\u003eRated for both AC and DC networks, expanding installation flexibility\u003c\/li\u003e\n  \u003cli\u003eApproved as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eTrip indicator provides local signalling of fault conditions\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block compatible (upper or lower) for efficient panel wiring\u003c\/li\u003e\n  \u003cli\u003eHigh limitation class 3 for reduced let-through energy during fault events\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial installations\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection in three-phase and four-wire AC distribution panels\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection up to 250 V in photovoltaic or battery storage systems\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring high short-circuit breaking performance\u003c\/li\u003e\n  \u003cli\u003eInstallations where the circuit breaker also functions as an isolating switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-2, EN 60947-2, EN 60898-1, and IEC 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74463, Schneider Electric A9F74463, Acti9 iC60N 4P 63A MCB, Schneider 63A 4-pole C-curve miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075316314376,"sku":"SCHA9F74463","price":34.19,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74463-miniature-circuit-breaker-mcb-acti9-ic60n-4p-63a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-738055.jpg?v=1735230427"},{"product_id":"a9f95432-miniature-circuit-breaker-mcb-acti9-ic60l-4p-32a-k-curve-15000a-iec-en-60898-1-20ka-iec-en-60947-2","title":"Schneider A9F95432 Acti9 iC60L MCB 4P 32 A K Curve 20kA","description":"\u003cp\u003eThe Schneider Electric A9F95432 is a 4-pole miniature circuit breaker (MCB) from the Acti 9 iC60L series, rated at 32 A with a K tripping characteristic. It delivers an ultimate breaking capacity (Icu) of 20 kA at 380-415 V AC, operates on both AC and DC networks, and is designed for electrical power distribution in demanding installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F95432\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 32 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: K\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 15 kA at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 380-415 V AC \/ 15 kA at 440 V AC \/ 70 kA at 12-133 V AC \/ 15 kA at 220-250 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limitation: 12 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 72 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-35 mm² rigid \/ 1-25 mm² flexible conductors\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN 60947-2, IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eK tripping curve with magnetic trip threshold at 12 x In (+\/- 20%) for reliable protection of circuits with high inrush currents\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60947-2, providing disconnect functionality\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator deliver clear local visual status at a glance\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block compatible at upper or lower terminals, simplifying panel wiring\u003c\/li\u003e\n  \u003cli\u003eMechanical durability of 20,000 cycles and electrical durability of 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eElectrical power distribution boards in industrial and commercial installations\u003c\/li\u003e\n  \u003cli\u003eProtection of AC and DC circuits subject to high inrush currents where K-curve selectivity is required\u003c\/li\u003e\n  \u003cli\u003e4-pole switching and short-circuit protection in main and sub-distribution panels\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category IV installations per EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60947-2 and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F95432, Schneider Electric A9F95432, iC60L 4P 32A K-curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075502240008,"sku":"SCHA9F95432","price":50.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9f95432-miniature-circuit-breaker-mcb-acti9-ic60l-4p-32a-k-curve-15000a-iecen-60898-1-20ka-iecen-60947-2-502098.jpg?v=1745851070"},{"product_id":"a9f95450-miniature-circuit-breaker-acti9-ic60l-4p-50-a-k-curve-15000-a-iec-60898-1-15-ka-iec-60947-2","title":"Schneider A9F95450 Acti9 iC60L MCB 4P 50 A K Curve 20kA","description":"\u003cp\u003eThe Schneider Electric A9F95450 is an Acti 9 iC60L 4-pole miniature circuit breaker rated at 50 A with a K tripping curve, designed for AC and DC power distribution applications. It offers a high ultimate breaking capacity of 70 kA at 12-133 V AC and 15 kA at 380-415 V AC per EN\/IEC 60947-2. The thermomagnetic protective unit with current limiting class 3 ensures fast, reliable overcurrent protection.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F95450\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 50 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: K\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtective unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eUltimate breaking capacity [Icu]: 70 kA at 12-133 V AC 50\/60 Hz; 15 kA at 380-415 V AC 50\/60 Hz; 10 kA at 440 V AC 50\/60 Hz; 15 kA at 220-250 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 35 kA at 12-133 V AC; 7.5 kA at 380-415 V AC; 15 kA at 220-240 V AC; 20 kA at 180-250 V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limiting: 12 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eUtilisation category: Category A (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 72 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eProduct weight: 0.5 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-35 mm² rigid \/ 1-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN 60947-2, IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eK tripping curve provides delayed response to moderate overloads, ideal for loads with high inrush currents\u003c\/li\u003e\n  \u003cli\u003eAC and DC network compatibility extends application flexibility across mixed distribution systems\u003c\/li\u003e\n  \u003cli\u003eCurrent limiting class 3 minimises let-through energy, protecting downstream equipment\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks (top or bottom) for compact panel wiring\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-35 to 70 °C) suits demanding industrial environments\u003c\/li\u003e\n  \u003cli\u003eTrip position indicator provides immediate visual fault indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial power distribution boards requiring high breaking capacity on AC or DC networks\u003c\/li\u003e\n  \u003cli\u003eMotor and transformer feeders with high inrush currents where K curve characteristics are required\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial switchgear panels in harsh or high-pollution environments\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems in renewable energy or battery-backed installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60947-2 and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F95450, Schneider Electric A9F95450, iC60L 4P 50A K curve MCB, Acti9 4-pole 50A circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075502338312,"sku":"SCHA9F95450","price":51.27,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f95450-miniature-circuit-breaker-acti9-ic60l-4p-50-a-k-curve-15000-a-iec-60898-1-15-ka-iec-60947-2-839140.jpg?v=1735230864"},{"product_id":"a9n18372-miniature-circuit-breaker-mcb-acti9-c120n-4p-80a-c-curve-10000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9N18372 Acti9 C120N MCB 4P 80 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18372 is a 4-pole, 80 A miniature circuit breaker from the Acti 9 C120N range, featuring a C tripping curve and a 10 kA breaking capacity at 230-400 V AC for electrical energy distribution. Its thermomagnetic protection technology and suitability for use as an isolating device make it an effective choice for main distribution boards and industrial panels.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9N18372\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 C120\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P, 4 protected poles\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 80 A at 30°C\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 220-415 V AC \/ up to 500 V DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 10 kA at 230-400 V AC (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eUltimate breaking capacity [Icu]: 20 kA at 220-240 V AC \/ 10 kA at 380-415 V AC \/ 6 kA at 440 V AC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, 35 mm symmetrical DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals, 1-50 mm² solid \/ 1.5-35 mm² flexible; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 108 x 81 x 73 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.82 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCertification: EAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for use as an isolating device per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eHandle sealable in ON or OFF position with 0.7 mm cable diameter\u003c\/li\u003e\n  \u003cli\u003eCompatible with busbar comb connection systems for efficient panel wiring\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 for reduced let-through energy per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25 to 70°C for demanding environments\u003c\/li\u003e\n  \u003cli\u003eContact position indicator for clear ON\/OFF status reading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCircuit protection in main and sub-distribution boards\u003c\/li\u003e\n  \u003cli\u003eIndustrial and commercial electrical energy distribution panels\u003c\/li\u003e\n  \u003cli\u003e3-phase plus neutral circuit protection in industrial control panels\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in systems up to 500 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9N18372, Schneider Electric A9N18372, C120N 4-pole 80A MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075616567560,"sku":"SCHA9N18372","price":94.77,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18372-miniature-circuit-breaker-mcb-acti9-c120n-4p-80a-c-curve-10000a-iecen-60898-1-10ka-iecen-60947-2-210081.jpg?v=1735231075"},{"product_id":"a9n18393-miniature-circuit-breaker-mcb-acti9-c120n-4p-125a-d-curve-10000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9N18393 Acti9 C120N MCB 4P 125 A D Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18393 is a 4-pole 125 A miniature circuit breaker (MCB) from the Acti 9 C120N range, built for electrical power distribution. Equipped with a D tripping curve and thermomagnetic protection technology, it delivers a breaking capacity of 10 kA Icn at 230...400 V AC per EN\/IEC 60898-1, suited for circuits with high inrush currents.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9N18393\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 C120\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P (4 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 125 A at 30°C\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 220...415 V AC 50\/60 Hz \/ up to 500 V DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: D\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 10...14 x In\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 10 kA at 230...400 V AC (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eUltimate breaking capacity [Icu]: 20 kA at 220...240 V AC \/ 10 kA at 380...415 V AC \/ 6 kA at 440 V AC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm symmetrical DIN rail, click-on system\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 108 x 81 x 73 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.82 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals, 1...50 mm² rigid \/ 1.5...35 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eCertification: EAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eD curve thermomagnetic tripping provides reliable protection for circuits with high inrush current loads\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per IEC 60947-2, enabling safe maintenance isolation\u003c\/li\u003e\n  \u003cli\u003eClick-on DIN rail mounting with comb busbar compatibility simplifies panel assembly\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and ON\/OFF local signalling give clear visual status at a glance\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25...70°C supports use in demanding environments\u003c\/li\u003e\n  \u003cli\u003eDifferential protection capability available via a separate add-on block\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain and sub-distribution boards in commercial and industrial electrical installations\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits subject to high inrush currents\u003c\/li\u003e\n  \u003cli\u003eLow-voltage switchgear assemblies requiring combined AC and DC circuit protection\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels where isolating function at distribution level is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 C120 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9N18393, Schneider Electric A9N18393, Acti9 C120N 4P 125A D curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075621679368,"sku":"SCHA9N18393","price":146.42,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9n18393-miniature-circuit-breaker-mcb-acti9-c120n-4p-125a-d-curve-10000a-iecen-60898-1-10ka-iecen-60947-2-268791.jpg?v=1745850847"},{"product_id":"a9f79425-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-4p-c25a-6ka","title":"Schneider Electric A9F79425 Acti9 iC60N MCB 4P 25A C Curve Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9F79425 Acti9 iC60N is a 4-pole miniature circuit breaker designed for low-voltage electrical distribution. It protects circuits against overloads and short circuits using thermal-magnetic trip technology.\u003c\/p\u003e\n\u003cp\u003eThis model is rated at 25A with a C curve, making it suitable for circuits where the expected inrush current is higher than very light-load applications. It is a practical choice for electricians, panel builders, maintenance teams, and procurement buyers who need a trusted Schneider Electric MCB with clear technical specifications.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":52952058757384,"sku":"SCHA9F79425","price":29.86,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f79425-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-4p-c25a-6ka-3700552.png?v=1765818669"},{"product_id":"a9k24410-schneider-electric-miniature-circuit-breaker-mcb-acti9-ik60n-4p-c10a-6ka","title":"Schneider A9K24410 Miniature Circuit Breaker (MCB), Acti9 iK60N 4P C10A 6kA","description":"\u003cp\u003eThe Schneider Electric A9K24410 is a 4-pole miniature circuit breaker (MCB) from the Acti9 iK60N series, rated at 10A with a C tripping curve and 6000A breaking capacity. Designed for distribution applications, it provides reliable thermal-magnetic overcurrent protection on AC networks up to 400V.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K24410\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti9 iK60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iK60N\u003c\/li\u003e\n  \u003cli\u003ePoles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 10A at 30°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage [Ue]: 400V AC 50\/60Hz\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60Hz\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000A at 400V AC conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated service breaking capacity [Ics]: 6000A (100% x Icn) at 400V AC\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440V AC 50\/60Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4kV\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, 35mm DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection pitch: 18mm between phases\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type (top or bottom), rigid 1...25mm², flexible 1...16mm²\u003c\/li\u003e\n  \u003cli\u003eWire stripping length: 14mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 conforming to IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...60°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85°C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: II\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 72 x 85 x 78.5mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 400g\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eControl type: Toggle\u003c\/li\u003e\n  \u003cli\u003eSuitability for isolation: Yes conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: SNI\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e4-pole configuration protects all phases simultaneously in three-phase and neutral distribution circuits\u003c\/li\u003e\n  \u003cli\u003eC curve characteristic suitable for distribution loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003e6000A breaking capacity (Ics 100% x Icn) ensures full rated service performance without derating\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation, eliminating the need for a separate isolator in many applications\u003c\/li\u003e\n  \u003cli\u003ePadlocking device option allows locking in open position for maintenance safety\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25...60°C suits demanding installation environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of three-phase loads and sub-circuits in low-voltage panels\u003c\/li\u003e\n  \u003cli\u003eMain or sub-circuit protection in residential and light industrial distribution systems\u003c\/li\u003e\n  \u003cli\u003eDIN rail panel assemblies requiring compact 4-pole overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti9 iK60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K24410, Schneider Electric A9K24410, Acti9 4-pole MCB 10A, iK60N C10 4P circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":52952062034184,"sku":"SCHA9K24410","price":14.83,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k24410-schneider-electric-miniature-circuit-breaker-mcb-acti9-ik60n-4p-c10a-6ka-8090391.jpg?v=1765818552"},{"product_id":"a9k24416-schneider-electric-miniature-circuit-breaker-mcb-acti9-ik60n-4p-c16a-6ka","title":"Schneider A9K24416 Miniature Circuit Breaker (MCB), Acti9 iK60N 4P C16A 6kA","description":"\u003cp\u003eThe Schneider Electric A9K24416 is a 4-pole miniature circuit breaker (MCB) from the Acti9 iK60N series, rated at 16A with a C tripping curve and 6000A breaking capacity, designed for distribution applications in AC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K24416\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti9 iK60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iK60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 16 A at 30°C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage [Ue]: 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated service breaking capacity [Ics]: 6000 A (100% x Icn) at 400 V AC\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eSuitability for isolation: Yes\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 conforming to IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...60°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85°C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: II\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, 35 mm DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection pitch: 18 mm between phases\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type (top or bottom), 1...25 mm² rigid \/ 1...16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eWire stripping length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eWidth: 72 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 400 g\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: SNI\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit with C curve provides reliable overload and short-circuit protection for distribution circuits\u003c\/li\u003e\n  \u003cli\u003eFull 6000 A rated service breaking capacity (100% Ics) at 400 V AC ensures consistent performance under fault conditions\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation conforming to EN\/IEC 60898-1, enabling safe maintenance procedures\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting and tunnel-type terminals simplify installation and wiring\u003c\/li\u003e\n  \u003cli\u003ePadlocking device option available for lockout\/tagout safety compliance\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-25...60°C) supports use in demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of three-phase circuits and equipment in electrical distribution panels\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring 4-pole overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eDistribution networks where isolation capability is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti9 iK60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K24416, Schneider Electric A9K24416, Acti9 iK60N 4P C16A MCB, Schneider 4-pole miniature circuit breaker 16A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":52952062165256,"sku":"SCHA9K24416","price":13.16,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k24416-schneider-electric-miniature-circuit-breaker-mcb-acti9-ik60n-4p-c16a-6ka-8613583.jpg?v=1765818551"},{"product_id":"a9k24420-schneider-electric-miniature-circuit-breaker-mcb-acti9-ik60n-4p-c20a-6ka","title":"Schneider A9K24420 Miniature Circuit Breaker (MCB), Acti9 iK60N 4P C20A 6kA","description":"\u003cp\u003eThe Schneider Electric A9K24420 is a 4-pole miniature circuit breaker (MCB) from the Acti9 iK60N range, designed for distribution applications. It provides thermal-magnetic protection at 20 A rated current with a C tripping curve and a breaking capacity of 6000 A at 400 V AC, conforming to EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K24420\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti9 iK60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iK60N\u003c\/li\u003e\n  \u003cli\u003ePoles: 4P (4 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 20 A at 30 °C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage [Ue]: 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated service breaking capacity [Ics]: 6000 A (100% x Icn) at 400 V AC conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eSuitability for isolation: Yes, conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, 35 mm DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection type: Tunnel type terminal (top or bottom), rigid 1...25 mm², flexible 1...16 mm²\u003c\/li\u003e\n  \u003cli\u003eWire stripping length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 conforming to IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2 conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: II\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 72 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 400 g\u003c\/li\u003e\n  \u003cli\u003eColour: White\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eConnection pitch between phases: 18 mm\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: SNI\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit provides reliable overload and short-circuit protection for distribution circuits.\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity of 6000 A (Icn) with 100% rated service breaking capacity (Ics) ensures performance under fault conditions.\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation conforming to EN\/IEC 60898-1, allowing the device to serve as a safe disconnection point.\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting and tunnel-type terminals simplify installation and wiring in distribution boards.\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25...60 °C supports use in demanding environmental conditions.\u003c\/li\u003e\n  \u003cli\u003ePadlocking device option enables lockout\/tagout procedures for maintenance safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings requiring 4-pole circuit protection.\u003c\/li\u003e\n  \u003cli\u003eProtection of three-phase and neutral circuits in low-voltage distribution panels.\u003c\/li\u003e\n  \u003cli\u003eElectrical installation panels where isolation capability and DIN rail mounting are required.\u003c\/li\u003e\n  \u003cli\u003eIndustrial control cabinets operating on 400 V AC three-phase networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti9 iK60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K24420, Schneider Electric A9K24420, Acti9 iK60N 4P C20A MCB, Schneider 4-pole miniature circuit breaker 20A C curve.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":52952062296328,"sku":"SCHA9K24420","price":14.29,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k24420-schneider-electric-miniature-circuit-breaker-mcb-acti9-ik60n-4p-c20a-6ka-6237523.jpg?v=1765818612"},{"product_id":"a9k24425-schneider-electric-miniature-circuit-breaker-mcb-acti9-ik60n-4p-c25a-6ka","title":"Schneider A9K24425 Miniature Circuit Breaker (MCB), Acti9 iK60N 4P C25A 6kA","description":"\u003cp\u003eThe Schneider Electric A9K24425 is a 4-pole miniature circuit breaker (MCB) from the Acti9 iK60N range, rated at 25A with a C tripping curve and a breaking capacity of 6000A at 400V AC. Designed for distribution applications, it offers thermal-magnetic trip technology and is suitable for isolation in compliance with EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K24425\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti9 iK60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iK60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 25A at 30°C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage [Ue]: 400V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000A at 400V AC conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated service breaking capacity [Ics]: 6000A (100% x Icn) at 400V AC\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, 35 mm DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection type: Tunnel type terminal (top or bottom), 1...25 mm² rigid \/ 1...16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 conforming to IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...60°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85°C\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 72 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 400 g\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: SNI\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation conforming to EN\/IEC 60898-1, enabling safe maintenance isolation\u003c\/li\u003e\n  \u003cli\u003eC tripping curve with thermal-magnetic technology for reliable overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003ePadlocking device option for lockout\/tagout procedures\u003c\/li\u003e\n  \u003cli\u003eCompact DIN rail mounting with 9 mm pitch modules for space-efficient panel installation\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-25...60°C) suitable for demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial distribution panels requiring 4-pole protection\u003c\/li\u003e\n  \u003cli\u003eProtection of three-phase loads with neutral in low-voltage installations\u003c\/li\u003e\n  \u003cli\u003eDistribution applications where isolation capability is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K24425, Schneider Electric A9K24425, Acti9 iK60N 4P 25A MCB, Schneider 4-pole miniature circuit breaker 25A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":52952062394632,"sku":"SCHA9K24425","price":16.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k24425-schneider-electric-miniature-circuit-breaker-mcb-acti9-ik60n-4p-c25a-6ka-2026846.jpg?v=1765818551"},{"product_id":"a9k24440-schneider-electric-miniature-circuit-breaker-mcb-acti9-ik60n-4p-c40a-6ka","title":"Schneider A9K24440 Miniature Circuit Breaker (MCB), Acti9 iK60N 4P C40A 6kA","description":"\u003cp\u003eThe Schneider Electric A9K24440 is a 4-pole miniature circuit breaker (MCB) from the Acti9 iK60N series, rated at 40A with a C tripping curve and 6000A breaking capacity per IEC\/EN 60898-1. Designed for distribution applications on AC networks, it provides reliable overcurrent protection with thermal-magnetic trip technology.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K24440\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti9 iK60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iK60N\u003c\/li\u003e\n  \u003cli\u003eApplication: Distribution\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A at 30°C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage [Ue]: 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated service breaking capacity [Ics]: 6000 A (100% x Icn) at 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eSuitability for isolation: Yes\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, 35 mm DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection pitch: 18 mm between phases\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type (top or bottom), rigid 1...35 mm², flexible 1...25 mm²\u003c\/li\u003e\n  \u003cli\u003eWire stripping length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eWidth: 72 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 400 g\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...60°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85°C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: II\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: SNI\u003c\/li\u003e\n  \u003cli\u003eColour: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip technology provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n  \u003cli\u003eC tripping curve with magnetic range of 5...10 x In suits distribution circuits with moderate inrush loads.\u003c\/li\u003e\n  \u003cli\u003e100% rated service breaking capacity (Ics = Icn = 6000 A) ensures consistent performance under fault conditions.\u003c\/li\u003e\n  \u003cli\u003ePadlocking device option supports lockout\/tagout safety procedures.\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-25...60°C) allows installation in demanding environments.\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1, enabling use as a disconnecting means.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings.\u003c\/li\u003e\n  \u003cli\u003eIndustrial distribution panels requiring 4-pole overcurrent protection on 400 V AC networks.\u003c\/li\u003e\n  \u003cli\u003eProtection of three-phase and neutral conductors in sub-distribution systems.\u003c\/li\u003e\n  \u003cli\u003eControl panels where lockout\/tagout isolation capability is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti9 iK60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K24440, Schneider Electric A9K24440, Acti9 iK60N 4P 40A MCB, 4-pole miniature circuit breaker C40.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":52952062460168,"sku":"SCHA9K24440","price":18.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k24440-schneider-electric-miniature-circuit-breaker-mcb-acti9-ik60n-4p-c40a-6ka-3570621.jpg?v=1765818610"},{"product_id":"a9f84402-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-4p-c2a-10ka","title":"Schneider A9F84402 Miniature Circuit Breaker (MCB), Acti9 iC60H, 4P C2A 10kA","description":"\u003cp\u003eThe Schneider Electric A9F84402 is a 4-pole Miniature Circuit Breaker (MCB) from the Acti 9 iC60H series, rated at 2A with C tripping characteristic. Designed for electrical power distribution, it delivers a breaking capacity of 10,000A Icn at 400V AC and up to 70kA Icu at 380-415V AC, making it suitable for demanding installation environments.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F84402\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60H\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 2A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 10,000A Icn at 400V AC per EN\/IEC 60898-1; 70kA Icu at 380-415V AC per EN\/IEC 60947-2; 15kA Icu at up to 250V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500V AC 50\/60Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6kV\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 72 x 85 x 78.5mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.5kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25mm² rigid \/ 1-16mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh breaking capacity of 70kA Icu at 380-415V AC, suitable for high-fault-current installations\u003c\/li\u003e\n  \u003cli\u003eSuitable for both AC and DC networks, providing installation flexibility\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for quick local status monitoring\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks (top or bottom), simplifying panel wiring\u003c\/li\u003e\n  \u003cli\u003eTropicalization grade 2 per IEC 60068-1, ensuring reliable operation in humid environments\u003c\/li\u003e\n  \u003cli\u003ePollution degree 3 rated, suitable for industrial environments with conductive contamination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of low-current circuits in electrical distribution panels\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring high breaking capacity MCBs\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in renewable energy and battery systems\u003c\/li\u003e\n  \u003cli\u003ePanel installations in humid or tropical environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F84402, Schneider Electric A9F84402, iC60H 4P 2A MCB, Acti9 miniature circuit breaker 4 pole 2A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53107742212360,"sku":"SCHA9F84402","price":39.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f84402-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-4p-c2a-10ka-6033495.jpg?v=1768101306"},{"product_id":"a9n18374-schneider-electric-miniature-circuit-breaker-mcb-acti9-c120n-4p-c100a-10ka","title":"Schneider A9N18374 Miniature Circuit Breaker (MCB), Acti9 C120N, 4P C100A 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18374 is a 4-pole miniature circuit breaker (MCB) from the Acti 9 C120N range, rated at 100 A with a C tripping characteristic. Designed for electrical power distribution, it delivers a breaking capacity of 10,000 A Icn at 230-400 V AC and supports both AC and DC network types.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9N18374\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 C120\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 100 A at 30 °C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 380-415 V AC 50\/60 Hz; 220-240 V AC 50\/60 Hz; 440 V AC 50\/60 Hz; up to 500 V DC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 10,000 A at 230-400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 20 kA at 220-240 V AC; 10 kA at 380-415 V AC; 6 kA at 440 V AC; 10 kA at up to 500 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 7,500 A (75%) at 230-400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5-10 x In\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 108 x 81 x 73 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.82 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, 35 mm symmetrical DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection type: Tunnel terminals, 1-50 mm² solid \/ 1.5-35 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 5,000 cycles per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-2, EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: EAC\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per IEC 60947-2, enabling safe disconnection of circuits\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks for simplified panel wiring\u003c\/li\u003e\n  \u003cli\u003eHandle sealable in ON or OFF position with cable diameter 0.7 mm for tamper protection\u003c\/li\u003e\n  \u003cli\u003eContact position indicator with ON\/OFF local signalling for quick visual status check\u003c\/li\u003e\n  \u003cli\u003eSupports both AC and DC networks up to 500 V, providing installation flexibility\u003c\/li\u003e\n  \u003cli\u003eTropicalization class 2 and 95% relative humidity rating at 55 °C for demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings requiring 100 A 4-pole protection\u003c\/li\u003e\n  \u003cli\u003eMain circuit protection in electrical distribution panels with DIN rail mounting\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in solar PV and battery storage systems up to 500 V\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels where isolation capability and high breaking capacity are required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2 and EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 C120 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9N18374, Schneider Electric A9N18374, Acti9 C120N 4P 100A MCB, Schneider 100A 4-pole miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53453077741832,"sku":"SCHA9N18374","price":114.63,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18374-schneider-electric-miniature-circuit-breaker-mcb-acti9-c120n-4p-c100a-10ka-7529034.jpg?v=1773354562"},{"product_id":"a9n18376-schneider-electric-miniature-circuit-breaker-mcb-acti9-c120n-4p-c125a-10ka","title":"Schneider A9N18376 Miniature Circuit Breaker (MCB), Acti9 C120N, 4P C125A 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18376 is a 4-pole miniature circuit breaker (MCB) from the Acti 9 C120N series, rated at 125 A with a C tripping characteristic. Designed for electrical power distribution, it provides thermomagnetic protection with a breaking capacity of 10 kA at 230-400 V AC, making it suitable for demanding industrial and commercial installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9N18376\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 C120\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 125 A at 30 °C\u003c\/li\u003e\n  \u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 10 kA at 230-400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 20 kA at 220-240 V AC \/ 10 kA at 380-415 V AC \/ 6 kA at 440 V AC \/ 10 kA at \u0026lt;=500 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 7500 A (75%) at 230-400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 380-415 V AC 50\/60 Hz \/ 220-240 V AC \/ 440 V AC \/ \u0026lt;=500 V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 5-10 x In\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 108 x 81 x 73 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.82 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, 35 mm symmetrical DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel terminals 1-50 mm² solid \/ 1.5-35 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 15 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eOperating altitude: up to 2000 m\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3 per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 5,000 cycles per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-2, EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertification: EAC\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per IEC 60947-2, allowing use as a disconnection device\u003c\/li\u003e\n  \u003cli\u003eHandle sealable with cable diameter 0.7 mm in OFF or ON position for tamper protection\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks for simplified panel wiring\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and ON\/OFF local signalling for clear status reading\u003c\/li\u003e\n  \u003cli\u003eTropicalization grade 2 per IEC 60068-1 for use in humid environments\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25 to 70 °C for versatile installation conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain and sub-main protection in industrial and commercial electrical distribution boards\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in low-voltage switchgear and controlgear assemblies\u003c\/li\u003e\n  \u003cli\u003eDistribution panels requiring high breaking capacity with DC voltage compatibility\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring isolation capability alongside overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels operating in high pollution or humid environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2 and EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 C120 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9N18376, Schneider Electric A9N18376, Acti9 C120N 4P 125A MCB, Schneider 125A 4-pole miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53453077807368,"sku":"SCHA9N18376","price":113.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18376-schneider-electric-miniature-circuit-breaker-mcb-acti9-c120n-4p-c125a-10ka-3498449.jpg?v=1773354560"},{"product_id":"a9n18479-schneider-electric-miniature-circuit-breaker-mcb-acti9-c120h-4p-c80a-15ka","title":"Schneider A9N18479 Miniature Circuit Breaker (MCB), Acti9 C120H, 4P C80A 15kA","description":"\u003cp\u003eThe Schneider Electric A9N18479 is a 4-pole miniature circuit breaker (MCB) from the Acti 9 C120H series, rated 80A at 30°C with a C tripping curve, designed for electrical power distribution. It provides a breaking capacity of 15,000A Icn at 230-400V AC per IEC 60898-1 and 15 kA Icu at 380-415V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9N18479\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 C120\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eRated current: 80A at 30°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 15,000A at 230-400V AC 50\/60 Hz per IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 30 kA at 220-240V AC; 15 kA at 380-415V AC; 10 kA at 440V AC; 15 kA at up to 500V DC per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated voltage (Ue): 220-440V AC 50\/60 Hz; up to 500V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500V AC per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: 35mm symmetrical DIN rail, clip-on system\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type, 1-50mm² rigid \/ 1.5-35mm² flexible\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -30 to 60°C\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 108 x 81 x 73 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.82 kg\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-2, EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertification: EAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eBreaking capacity of 30 kA at 220-240V AC enables use in high fault-current installations\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per IEC 60947-2, removing the need for a separate isolating switch\u003c\/li\u003e\n  \u003cli\u003eHandle sealable with 0.7mm cable in both ON and OFF positions to prevent unauthorized switching\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks and standard 35mm DIN rail\u003c\/li\u003e\n  \u003cli\u003eRated for DC systems up to 500V with 15 kA Icu breaking capacity\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance of 20,000 cycles and 5,000 electrical operating cycles per IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain and sub-distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eOutgoing circuit protection in panels with high prospective fault currents\u003c\/li\u003e\n  \u003cli\u003eDC distribution up to 500V in industrial or renewable energy installations\u003c\/li\u003e\n  \u003cli\u003eSwitchboards requiring combined overcurrent protection and isolation capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2 and EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 C120 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9N18479, Schneider Electric A9N18479, Acti9 C120H 4P MCB 80A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53453077840136,"sku":"SCHA9N18479","price":128.97,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18479-schneider-electric-miniature-circuit-breaker-mcb-acti9-c120h-4p-c80a-15ka-1748963.jpg?v=1773354559"},{"product_id":"18672-schneider-electric-miniature-circuit-breaker-mcb-acti9-ng125n-4p-d80a-25ka","title":"Schneider 18672 Miniature Circuit Breaker (MCB), Acti9 NG125N, 4P 80A, 25kA","description":"\u003cp\u003eSchneider Electric commercial reference 18672 is a 4-pole miniature circuit breaker (MCB) from the Acti 9 NG125N series, rated at 80A with a D tripping curve for distribution of electrical energy. It provides high breaking capacity up to 25kA at 380-415V AC and supports both AC and DC network types with thermomagnetic protection technology.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 18672\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 NG125\u003c\/li\u003e\n  \u003cli\u003eDevice short name: NG125N\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 80A at 40°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: D\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 50kA at 220-240V AC 50\/60Hz - 25kA at 380-415V AC 50\/60Hz - 20kA at 440V AC 50\/60Hz - 10kA at 500V AC 50\/60Hz - 20kA at 500V DC (per EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 37.5kA at 220-240V AC - 18.75kA at 380-415V AC - 15kA at 440V AC - 7.5kA at 500V AC - 20kA at 500V DC\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 220-240V \/ 380-415V \/ 440V \/ 500V AC 50\/60Hz; up to 500V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690V AC 50\/60Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 8kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 12 x In\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: Click-on system, 35mm symmetrical DIN rail\u003c\/li\u003e\n  \u003cli\u003eHandle position: Vertical\u003c\/li\u003e\n  \u003cli\u003eWidth: 108mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 103mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 81mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.96kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eIK protection rating: IK05 per EN\/IEC 62262\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -30 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 70°C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eConnection type: Tunnel terminals 16-70mm² rigid \/ 10-50mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 20mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 6 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 5000 cycles\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3 per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eD tripping curve suits loads with high inrush currents, reducing nuisance tripping in demanding applications\u003c\/li\u003e\n  \u003cli\u003eDual AC\/DC network compatibility makes the NG125N suitable for both conventional and DC-coupled installations\u003c\/li\u003e\n  \u003cli\u003eHigh breaking capacity of 25kA at 380-415V AC provides robust short-circuit protection in industrial environments\u003c\/li\u003e\n  \u003cli\u003eIntegrated lockout capability allows the handle to be secured in the OFF position for maintenance safety\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator provide clear local signalling of device status\u003c\/li\u003e\n  \u003cli\u003eClick-on DIN rail mounting and comb busbar-ready design simplify panel assembly and wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain circuit protection in industrial and commercial electrical distribution boards\u003c\/li\u003e\n  \u003cli\u003eProtection of motors and equipment with high starting inrush currents where D curve is required\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems and photovoltaic or battery-backed installations up to 500V DC\u003c\/li\u003e\n  \u003cli\u003eOutgoing feeder protection in low-voltage switchgear and control panels\u003c\/li\u003e\n  \u003cli\u003eFinal sub-distribution in facilities requiring high fault current withstand capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 NG125 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 18672, Schneider Electric 18672, NG125N 4P 80A D-curve MCB, Acti9 NG125N 80A 4-pole circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53901712457992,"sku":"SCH18672","price":223.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/18672-schneider-electric-miniature-circuit-breaker-mcb-acti9-ng125n-4p-d80a-25ka-1094398.jpg?v=1774878071"},{"product_id":"18737-schneider-electric-miniature-circuit-breaker-mcb-acti9-ng125h-4p-c40a-36ka","title":"Schneider 18737 Acti9 NG125H Miniature Circuit Breaker MCB DIN Rail","description":"\u003cp\u003eThe Schneider 18737 is an Acti9 NG125H series miniature circuit breaker (MCB) for DIN rail mounting in industrial and commercial distribution boards. The NG125H series provides high breaking capacity ratings for installations with elevated prospective fault currents.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePart number: 18737\u003c\/li\u003e\n\u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli\u003eSeries: Acti9 NG125H\u003c\/li\u003e\n\u003cli\u003eType: Miniature circuit breaker (MCB)\u003c\/li\u003e\n\u003cli\u003eDIN rail: 35mm TS-35\u003c\/li\u003e\n\u003cli\u003eStandards: IEC\/EN 60898-1, IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNG125H high breaking capacity for demanding industrial installations\u003c\/li\u003e\n\u003cli\u003eCompatible with Schneider Acti9 distribution system and accessories\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting for standard panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIndustrial distribution board protection\u003c\/li\u003e\n\u003cli\u003eSub-distribution circuits with high prospective fault current\u003c\/li\u003e\n\u003cli\u003eCommercial buildings requiring robust MCB protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eCompliant with IEC\/EN 60898-1, IEC 60947-2.\u003c\/p\u003e\u003cp\u003eAlso known as: Schneider 18737, Schneider Electric Acti9 NG125H MCB, Schneider NG125 series MCB, Schneider 18737 circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53901738705160,"sku":"SCH18737","price":150.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/18737-schneider-electric-miniature-circuit-breaker-mcb-acti9-ng125h-4p-c40a-36ka-6666447.jpg?v=1774878069"},{"product_id":"18829-schneider-electric-miniature-circuit-breaker-mcb-acti9-ng125l-4p-c80a-50-ka","title":"Schneider 18829 Acti9 NG125L 4P 80A C-Curve 50kA MCB","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Schneider Electric 18829 is an Acti9 NG125L miniature circuit breaker (MCB), 4-pole, 80 A, C-curve, with a 50 kA breaking capacity at 380...415 V AC according to EN\/IEC 60947-2. It protects distribution circuits against overload and short-circuit and provides isolation. \u003cstrong\u003eThis product is discontinued by Schneider Electric.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange: Acti9 NG125 (device short name: NG125L)\u003c\/li\u003e\n\u003cli\u003eType: Miniature circuit breaker, thermal-magnetic\u003c\/li\u003e\n\u003cli\u003ePoles: 4P, 4 protected poles, neutral on the left\u003c\/li\u003e\n\u003cli\u003eRated current [In]: 80 A at 40 °C\u003c\/li\u003e\n\u003cli\u003eTrip curve: C (magnetic trip 8 x In)\u003c\/li\u003e\n\u003cli\u003eNetwork: AC and DC\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icu, EN\/IEC 60947-2): 100 kA @ 220...240 V AC, 50 kA @ 380...415 V AC, 40 kA @ 440 V AC, 15 kA @ 500 V AC, 36 kA @ ≤500 V DC\u003c\/li\u003e\n\u003cli\u003eService breaking capacity (Ics): 37.5 kA @ 380...415 V AC (75% of Icu)\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage [Ui]: 690 V AC\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand [Uimp]: 8 kV\u003c\/li\u003e\n\u003cli\u003eUtilisation category: A; suitable for isolation per IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eMounting: clip-on, 35 mm symmetrical DIN rail, 12 x 9 mm pitches\u003c\/li\u003e\n\u003cli\u003eTerminals: tunnel-type, 16...70 mm² rigid \/ 10...50 mm² flexible; 6 N.m tightening torque; 20 mm stripping\u003c\/li\u003e\n\u003cli\u003eMechanical \/ electrical durability: 20 000 \/ 5 000 cycles\u003c\/li\u003e\n\u003cli\u003ePadlockable (integrated)\u003c\/li\u003e\n\u003cli\u003eIP20 \/ IK05; pollution degree 3; overvoltage category IV\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -30...70 °C\u003c\/li\u003e\n\u003cli\u003eDimensions: 103 x 108 x 81 mm (H x W x D); 0.96 kg\u003c\/li\u003e\n\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFinal and sub-distribution circuit protection\u003c\/li\u003e\n\u003cli\u003eIndustrial and tertiary distribution boards\u003c\/li\u003e\n\u003cli\u003eDC applications up to 500 V (e.g. battery and PV string protection within ratings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompliance\u003c\/h2\u003e\n\u003cp\u003eEN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote: This product has been discontinued by the manufacturer. Stock is limited to remaining inventory; no further production is planned.\u003c\/strong\u003e\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53901849035016,"sku":"SCH18829","price":237.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/18829-schneider-electric-miniature-circuit-breaker-mcb-acti9-ng125l-4p-c80a-50-ka-2566422.jpg?v=1774877964"},{"product_id":"18861-schneider-electric-miniature-circuit-breaker-mcb-acti9-ng125l-4p-d32a-50ka","title":"Schneider 18861 Miniature Circuit Breaker (MCB), Acti9 NG125L, 4P D32A 50kA","description":"\u003cp\u003eThe Schneider Electric 18861 is a 4-pole miniature circuit breaker (MCB) from the Acti9 NG125L series, rated at 32A with a D tripping curve and a breaking capacity of 50kA at 380-415V AC, designed for distribution applications in industrial and commercial installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 18861\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti9 NG125\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eDevice application: Distribution\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eNeutral position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 32A at 40°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: D\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 100kA at 220-240V AC - 50kA at 380-415V AC - 40kA at 440V AC - 15kA at 500V AC - 36kA at 500V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated service breaking capacity [Ics]: 75kA at 220-240V AC - 37.5kA at 380-415V AC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 8kV\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 12 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eUtilisation category: Category A (IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, 35mm symmetrical DIN rail, vertical\u003c\/li\u003e\n  \u003cli\u003eWidth: 108mm - Height: 103mm - Depth: 81mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.96kg\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type, 1.5-50mm² rigid \/ 1-35mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eIK protection: IK05 (EN\/IEC 62262)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -30 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 70°C\u003c\/li\u003e\n  \u003cli\u003eOperating altitude: 2000m\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3 (IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh breaking capacity of 50kA at 380-415V AC ensures reliable protection in demanding distribution networks\u003c\/li\u003e\n  \u003cli\u003eD curve thermal-magnetic trip unit suitable for loads with high inrush currents\u003c\/li\u003e\n  \u003cli\u003eSuitability for isolation confirmed per IEC 60947-2, enabling safe maintenance procedures\u003c\/li\u003e\n  \u003cli\u003eIntegrated padlocking provision for lockout\/tagout safety compliance\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbars and distribution blocks for flexible panel wiring\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-30 to 70°C) supports use in harsh environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial distribution boards and motor control centers requiring high breaking capacity\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial panels with loads exhibiting high inrush currents (D curve)\u003c\/li\u003e\n  \u003cli\u003ePower distribution in buildings with elevated short-circuit levels\u003c\/li\u003e\n  \u003cli\u003eMain and sub-distribution panels in factories, warehouses, and infrastructure projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2. Part of the Schneider Electric Acti9 NG125 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 18861, Schneider Electric 18861, NG125L 4P D32A, Acti9 NG125L MCB 32A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53901885833480,"sku":"SCH18861","price":183.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/18861-schneider-electric-miniature-circuit-breaker-mcb-acti9-ng125l-4p-d32a-50ka-4999292.jpg?v=1774877959"},{"product_id":"18862-schneider-electric-miniature-circuit-breaker-mcb-acti9-ng125l-4p-d40a-50ka","title":"Schneider 18862 Miniature Circuit Breaker (MCB), Acti9 NG125L, 4P D40A 50kA","description":"\u003cp\u003eSchneider Electric 18862 is a 4-pole miniature circuit breaker (MCB) from the Acti 9 NG125L series, rated at 40 A with a D tripping curve. Designed for AC and DC electrical power distribution, it delivers an ultimate breaking capacity of up to 100 kA at 220-240 V AC, making it suitable for demanding industrial and commercial installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 18862\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 NG125\u003c\/li\u003e\n  \u003cli\u003eDevice short name: NG125L\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 4\u003c\/li\u003e\n  \u003cli\u003eNeutral conductor position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A at 40°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: D\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 220-240 V AC \/ 380-415 V AC \/ 440 V AC \/ 500 V AC \/ ≤500 V DC (50\/60 Hz)\u003c\/li\u003e\n  \u003cli\u003eUltimate breaking capacity [Icu]: 100 kA at 220-240 V AC \/ 50 kA at 380-415 V AC \/ 40 kA at 440 V AC \/ 15 kA at 500 V AC \/ 36 kA at ≤500 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 75 kA at 220-240 V AC \/ 37.5 kA at 380-415 V AC \/ 30 kA at 440 V AC \/ 11.25 kA at 500 V AC \/ 50 kA at 500 V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 8 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 12 x In ±20%\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A (IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation: Yes (IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: Snap-on, 35 mm symmetrical DIN rail\u003c\/li\u003e\n  \u003cli\u003eHandle mounting position: Vertical\u003c\/li\u003e\n  \u003cli\u003eBusbar comb distribution block: Compatible (12 rows, 9 mm pitch)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 108 x 103 x 81 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.96 kg\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel terminals 1.5-50 mm² rigid \/ 1-35 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eWire stripping length: 20 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eIK rating: IK05 (EN\/IEC 62262)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3 (IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -30 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 70°C\u003c\/li\u003e\n  \u003cli\u003eOperating altitude: up to 2000 m\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eLockout provision: Integrated locking\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eD tripping curve designed for loads with high inrush currents such as motors and transformers\u003c\/li\u003e\n  \u003cli\u003eHigh ultimate breaking capacity up to 100 kA for use in high fault-current environments\u003c\/li\u003e\n  \u003cli\u003eDual network compatibility - suitable for both AC and DC systems up to 500 V\u003c\/li\u003e\n  \u003cli\u003eIntegrated lockout provision enables safe maintenance isolation\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator provide clear local status reading\u003c\/li\u003e\n  \u003cli\u003eBusbar comb distribution block compatible for efficient panel wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial and commercial electrical distribution boards requiring high breaking capacity\u003c\/li\u003e\n  \u003cli\u003eProtection of motor feeders and transformer primaries with significant inrush currents\u003c\/li\u003e\n  \u003cli\u003eMain incoming protection in switchboards operating at overvoltage category IV\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems up to 500 V\u003c\/li\u003e\n  \u003cli\u003ePower distribution in demanding environments with wide operating temperature ranges\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 NG125 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 18862, Schneider Electric 18862, NG125L 4P D40 MCB, Acti9 NG125L 40A D curve.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53901910933768,"sku":"SCH18862","price":178.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/18862-schneider-electric-miniature-circuit-breaker-mcb-acti9-ng125l-4p-d40a-50ka-6564446.jpg?v=1774877959"}],"url":"https:\/\/gabbyelectric.com\/collections\/4-pole-mcb.oembed?page=2","provider":"Gabby Electric","version":"1.0","type":"link"}